NEUTRON KERMA FACTORS FOR MAGNESIUM AND ALUMINUM MEASURED WITH LOW-PRESSURE PROPORTIONAL-COUNTERS

被引:10
|
作者
BUHLER, G
MENZEL, HG
SCHUHMACHER, H
DIETZE, G
GULDBAKKE, S
机构
[1] PHYS TECH BUNDESANSTALT,D-3300 BRUNSWICK,FED REP GER
[2] UNIV SAARLANDES,BORIS RAJEWSKY INST,FACHRICHTUNG BIOPHY & PHYS GRUNDLAGEN,D-6650 HOMBURG,FED REP GER
来源
PHYSICS IN MEDICINE AND BIOLOGY | 1986年 / 31卷 / 06期
关键词
D O I
10.1088/0031-9155/31/6/002
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
引用
收藏
页码:601 / 611
页数:11
相关论文
共 50 条
  • [21] HIGH-PRESSURE PROPORTIONAL-COUNTERS OPERATING IN PURE HYDROGEN
    BAMBERGER, A
    BRUNDIERS, HJ
    FISCHER, U
    FRIEDRICH, D
    HARTUNG, R
    RUNGE, K
    SCHAILE, O
    WEBER, C
    BABAEV, A
    ELISEEV, G
    GALAKTIONOV, Y
    KAMISHKOV, Y
    LUBIMOV, V
    SHEVCHENKO, V
    WLASOV, M
    NUCLEAR INSTRUMENTS & METHODS, 1978, 156 (1-2): : 107 - 110
  • [22] IONIZATION DISTRIBUTIONS AND A-150 PLASTIC KERMA FOR NEUTRONS BETWEEN 13.9 AND 19.0 MEV MEASURED WITH A LOW-PRESSURE PROPORTIONAL COUNTER
    MENZEL, HG
    BUHLER, G
    SCHUHMACHER, H
    MUTH, H
    DIETZE, G
    GULDBAKKE, S
    PHYSICS IN MEDICINE AND BIOLOGY, 1984, 29 (12): : 1537 - 1554
  • [23] ULTRA-HIGH PRESSURE PROPORTIONAL-COUNTERS .2. XENON
    SOOD, RK
    YE, Z
    MANCHANDA, RK
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1994, 344 (02): : 384 - 393
  • [24] DOSIMETRY IN MIXED NEUTRON PHOTON FIELDS WITH TISSUE-EQUIVALENT PROPORTIONAL-COUNTERS
    SCHREWE, UJ
    BREDE, HJ
    DIETZE, G
    RADIATION PROTECTION DOSIMETRY, 1989, 29 (1-2) : 41 - 45
  • [25] USE OF GAS PROPORTIONAL-COUNTERS FOR NEUTRON-FLUX MONITORS AT NBS LINAC
    WASSON, OA
    BULLETIN OF THE AMERICAN PHYSICAL SOCIETY, 1975, 20 (02): : 137 - 137
  • [26] ABSOLUTE ENERGY CALIBRATION OF HYDROGEN-CONTAINING PROPORTIONAL COUNTERS OF LOW-PRESSURE
    KONYUSHK.AG
    KOROLEV, VI
    SAVINSKI.AK
    FILYUSHK.IV
    PRIBORY I TEKHNIKA EKSPERIMENTA, 1973, (03): : 71 - 74
  • [27] DETERMINATION OF PHOTON AND NEUTRON DOSE FRACTIONS WITH TISSUE-EQUIVALENT PROPORTIONAL-COUNTERS
    SCHREWE, UJ
    SCHUHMACHER, H
    BREDE, HJ
    DIETZE, G
    RADIATION PROTECTION DOSIMETRY, 1990, 31 (1-4) : 143 - 147
  • [28] QUANTIFYING BACKGROUND COMPONENTS OF LOW-LEVEL GAS PROPORTIONAL-COUNTERS
    THEODORSSON, P
    RADIOCARBON, 1992, 34 (03) : 420 - 427
  • [29] THE X-RAY-SPECTRUM OF THE CYGNUS LOOP MEASURED WITH GAS SCINTILLATION PROPORTIONAL-COUNTERS
    TSUNEMI, H
    MANABE, M
    YAMASHITA, K
    KOYAMA, K
    PUBLICATIONS OF THE ASTRONOMICAL SOCIETY OF JAPAN, 1988, 40 (04) : 449 - 458
  • [30] ERRORS IN ESTIMATING NEUTRON QUALITY FACTOR USING LINEAL ENERGY-DISTRIBUTIONS MEASURED IN TISSUE-EQUIVALENT PROPORTIONAL-COUNTERS
    BORAK, TB
    STINCHCOMB, TG
    HEALTH PHYSICS, 1982, 43 (02): : 219 - 224