COMPENSATORS FOR 3-DIMENSIONAL TREATMENT PLANNING

被引:36
|
作者
MAGERAS, GS
MOHAN, R
BURMAN, C
BAREST, GD
KUTCHER, GJ
机构
[1] Department of Medical Physics, Memorial Sloan-Kettering Cancer Center
关键词
3-DIMENSIONAL TREATMENT PLANNING; COMPENSATORS;
D O I
10.1118/1.596699
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Presented here is a method of designing compensators for a single beam or one or more pairs of beams, not necessarily parallel opposed. The objective is to produce a flat distribution in a plane that may be perpendicular to the central ray or may be an arbitrarily oriented plane, for example, a plane that bisects the hinge angle between two beams. The method takes into account not only surface irregularities but also tissue inhomogeneities, hinge angles between beams, distance from the source, and even "horns" in the beam. The design process employs convolution of Monte Carlo generated pencil beams with photon fluence distributions, appropriately modified for the presence of beam modifiers (blocks and compensators), to compute dose in a flat homogeneous phantom. Corrections for inhomogeneities and surface curvature are applied by using computerized tomography information to determine the effective path length through tissue. Multiple interations are used to arrive at a compensator that properly incorporates changes in radiation transport, and therefore dose distribution, resulting from the presence of beam-shaping devices. In each iteration it is assumed that the required reduction in dose at a point can be achieved by reducing the fluence along the ray joining the source to computation point proportionately. The compensator design is represented as a finely spaced matrix of thickness values which is entered into a prorammable milling maching for fabrication. Dose measurements in phantom exposed to 6-MV x rays with and without compensation are presented.
引用
收藏
页码:133 / 140
页数:8
相关论文
共 50 条
  • [21] 3-DIMENSIONAL IRRADIATION PLANNING
    LEITNER, H
    STRAHLENTHERAPIE UND ONKOLOGIE, 1989, 165 (08): : 599 - 603
  • [22] COMPUTER-ASSISTED 3-DIMENSIONAL TREATMENT PLANNING SYSTEM
    REINSTEIN, LE
    MCSHAN, D
    WEBBER, BM
    GLICKSMAN, AS
    RADIOLOGY, 1978, 127 (01) : 259 - 264
  • [23] 3-DIMENSIONAL PHOTON TREATMENT PLANNING FOR HODGKINS-DISEASE
    BROWN, AP
    URIE, MM
    BAREST, G
    CHENG, E
    COIA, L
    EMAMI, BN
    GALVIN, J
    KUTCHER, J
    MANOLIS, J
    WONG, JW
    YAHALOM, J
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01): : 205 - 215
  • [24] DATA ACQUISITION-SYSTEM FOR 3-DIMENSIONAL TREATMENT PLANNING
    MANTEL, J
    PERRY, H
    WEINKAM, JJ
    RADIOLOGY, 1975, 115 (01) : 187 - 189
  • [25] ROLE OF INHOMOGENEITY CORRECTIONS IN 3-DIMENSIONAL PHOTON TREATMENT PLANNING
    WONG, JW
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01): : 59 - 69
  • [26] CREATION OF 3-DIMENSIONAL PATIENT MODELS FOR HYPERTHERMIA TREATMENT PLANNING
    JAMES, BJ
    SULLIVAN, DM
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1992, 39 (03) : 238 - 242
  • [27] 3-DIMENSIONAL TREATMENT PLANNING CONSIDERATIONS FOR PROSTATE-CANCER
    SIMPSON, JR
    PURDY, JA
    MANOLIS, JM
    PILEPICH, MV
    BURMAN, C
    FORMAN, J
    FUKS, Z
    CHENG, E
    CHU, J
    MATTHEWS, J
    MOHAN, R
    SOLIN, L
    TEPPER, J
    URIE, M
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1991, 21 (01): : 243 - 252
  • [28] 3-DIMENSIONAL MODELS FOR HEAD AND NECK TUMOR TREATMENT PLANNING
    EISELE, DW
    RICHTSMEIER, WJ
    GRAYBEAL, JC
    KOCH, WM
    ZINREICH, SJ
    LARYNGOSCOPE, 1994, 104 (04): : 433 - 439
  • [29] USE OF COMPUTED-TOMOGRAPHY FOR A 3-DIMENSIONAL TREATMENT PLANNING SYSTEM
    SCHLUSSELBERG, DS
    SMITH, WK
    WOODWARD, DJ
    PARKEY, RW
    COMPUTERIZED MEDICAL IMAGING AND GRAPHICS, 1988, 12 (01) : 25 - 32
  • [30] 3-DIMENSIONAL TREATMENT PLANNING FOR MAXILLARY CANCER USING A CT SIMULATOR
    NAGATA, Y
    OKAJIMA, K
    MURATA, R
    MITSUMORI, M
    MIZOWAKI, T
    TSUTSUI, K
    ONO, K
    NISHIMURA, Y
    HIRAOKA, M
    NISHIDAI, T
    TAKAHASHI, M
    ABE, M
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 1994, 30 (04): : 979 - 983