DIRECT AND SIMULTANEOUS DETERMINATION OF URIC-ACID AND GLUCOSE IN SERUM WITH ELECTROCHEMICAL FILTER/BIOSENSOR FLOW-INJECTION ANALYSIS SYSTEM

被引:12
|
作者
OKAWA, Y
KOBAYASHI, H
OHNO, T
机构
[1] Faculty of Engineering, Chiba University, Inage-ku, Chiba-shi, Chiba, 263
关键词
BIOSENSORS; FLOW INJECTION; URIC ACID; GLUCOSE; SERUM;
D O I
10.1016/0003-2670(95)00293-9
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A flow-through electrolysis cell, named an electrochemical filter (ECF), with a three-electrode configuration was developed for the elimination and determination of electrochemically active components in biofluids, which give generally a nonspecific response to electrochemical biosensors. The use of a reference electrode ensured the precise control of the working electrode potential of the ECF and thus the quantitative current efficiency of the electrolysis. A flow-injection analysis setup was constructed by connecting two ECFs and a flow-through amperometric biosensor for glucose in series for the direct and simultaneous determination of glucose and uric acid in serum. The first ECF coulometrically determined uric acid, and the second one eliminated interferents with the biosensor: the sample was thus treated on-the-fly and then delivered to the biosensor, so that it determined glucose amperometrically without interference. The concentrations of glucose and uric acid measured in human control sera agreed well with the values determined with conventional methods. The system exhibited the wide dynamic range in the high glucose concentration region, thus can be applied to the analysis of serum of hyperglycaemic patients.
引用
收藏
页码:137 / 143
页数:7
相关论文
共 50 条
  • [11] SIMULTANEOUS DETERMINATION OF CREATININE AND URIC-ACID IN SERUM BY HIGH-PERFORMANCE ION-EXCHANGE CHROMATOGRAPHY WITH DIRECT INJECTION
    ETOH, T
    IWATAKE, M
    MIYAZAKI, M
    HARADA, K
    NAKAYAMA, M
    SUGII, A
    UJI, Y
    OKABE, H
    [J]. JOURNAL OF LIQUID CHROMATOGRAPHY, 1992, 15 (09): : 1565 - 1575
  • [12] A FLOW-INJECTION SYSTEM FOR SIMULTANEOUS DETERMINATION OF STARCH AND GLUCOSE-CONCENTRATIONS
    UMOH, EF
    SCHUGERL, K
    [J]. JOURNAL OF CHEMICAL TECHNOLOGY AND BIOTECHNOLOGY, 1994, 61 (01) : 81 - 86
  • [13] An Automatic Flow-injection Micro-electrode Electrochemical Analysis System for Simultaneous Determination of Four Kinds of Serum Electrolytes
    Zhou Lei
    Lai Zhen-Yao
    Zhang Hui-Sheng
    Gao Xiu-Feng
    Li Yong-Sheng
    [J]. CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2011, 39 (06) : 809 - 814
  • [14] DETERMINATION OF SERUM URIC-ACID USING CLINICARD SYSTEM
    BIGLEY, RP
    ROMBAUER, RB
    LAWN, WG
    OMALLEY, JA
    [J]. CLINICAL CHEMISTRY, 1973, 19 (06) : 674 - 674
  • [15] SIMULTANEOUS ENZYMATIC ELECTROCHEMICAL DETERMINATION OF GLUCOSE AND L-GLUTAMINE IN HYBRIDOMA MEDIA BY FLOW-INJECTION ANALYSIS
    MEYERHOFF, ME
    TROJANOWICZ, M
    PALSSON, BO
    [J]. BIOTECHNOLOGY AND BIOENGINEERING, 1993, 41 (10) : 964 - 969
  • [16] FLOW-INJECTION ANALYSIS FOR URIC-ACID BY THE COMBINED USE OF AN IMMOBILIZED URICASE REACTOR AND A PEROXIDASE ELECTRODE
    YAO, T
    SATO, M
    WASA, T
    [J]. NIPPON KAGAKU KAISHI, 1985, (02) : 189 - 192
  • [17] A FLOW-INJECTION BIOSENSOR SYSTEM FOR THE AMPEROMETRIC DETERMINATION OF CREATININE - SIMULTANEOUS COMPENSATION OF ENDOGENOUS INTERFERENTS
    RUI, CS
    SONOMOTO, K
    OGAWA, HI
    KATO, Y
    [J]. ANALYTICAL BIOCHEMISTRY, 1993, 210 (01) : 163 - 171
  • [18] MULTIFUNCTIONAL FLOW-INJECTION BIOSENSOR FOR THE SIMULTANEOUS MEASUREMENT OF CREATININE, GLUCOSE, AND UREA
    RUI, CS
    OGAWA, HI
    SONOMOTO, K
    KATO, Y
    [J]. BIOSCIENCE BIOTECHNOLOGY AND BIOCHEMISTRY, 1993, 57 (02) : 191 - 194
  • [19] DIRECT DETERMINATION OF ZINC IN HUMAN SERUM BY FLOW-INJECTION SPECTROPHOTOMETRIC ANALYSIS
    HAYASHIBE, Y
    TAKEYA, M
    SAYAMA, Y
    [J]. ANALYTICAL SCIENCES, 1994, 10 (05) : 795 - 799
  • [20] Voltammetric flow-injection determination of glucose in blood serum
    Fitsev, IM
    Bakanina, YN
    Abdullin, IF
    Budnikov, GK
    [J]. INDUSTRIAL LABORATORY, 1998, 64 (07): : 426 - 427