Transcatheter interruption of large residual flow after device closure of "Type A" patent ductus arteriosus

被引:0
|
作者
Sridhar, Anuradha [1 ]
Subramanyan, Raghavan [1 ]
Rajasekar, Premsekar [1 ]
机构
[1] Frontier Lifeline Hosp & Dr K M Cherian Heart Fdn, Dept Paediat, R30C,Ambattur Ind Estate Rd,Mogappair, Madras, Tamil Nadu, India
关键词
Ductus arteriosus; endothelialization; residual shunt; transcatheter closure;
D O I
10.4103/0974-2069.99632
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
We report a case of 3-year-old girl who had persistence of large residual flow following transcatheter closure of a 6 mm Type A patent ductus arteriosus using a 12 x 10 mm duct occluder. Angiography revealed a large left-to-right shunt coursing through and exiting around the implanted device. Near total abolition of the residual shunt was achieved by initial implantation of an embolization coil within the duct occluder and subsequently an Amplatzer duct occluder (ADO II) adjacent to the duct occluder. This challenging case describes an additional technique of abolishing a large residual flow in and around a Nitinol duct occluder device.
引用
收藏
页码:210 / 212
页数:3
相关论文
共 50 条
  • [31] Transcatheter closure of large patent ductus arteriosus using the Amplatzer ductal occluder
    Lin, Ming-Chih
    Fu, Yun-Ching
    Jan, Sheng-Ling
    Ho, Chi-Lin
    Chi, Ching-Shiang
    Hwang, Betau
    ACTA CARDIOLOGICA SINICA, 2007, 23 (02) : 103 - 108
  • [32] Transcatheter closure of a large patent ductus arteriosus using jugular access in an infant
    Fernandes, Precylia
    Assaidi, Anass
    Baruteau, Alban-Elouen
    Fraisse, Alain
    JOURNAL OF THORACIC DISEASE, 2018, 10 (03) : E207 - E209
  • [33] TRANSCATHETER CLOSURE OF RESIDUAL PATENT DUCTUS-ARTERIOSUS SHUNTING AFTER THE RASHKIND OCCLUDER DEVICE USING SINGLE OR MULTIPLE GIANTURCO COILS
    HIJAZI, ZM
    GEGGEL, RL
    ALFADLEY, F
    CATHETERIZATION AND CARDIOVASCULAR DIAGNOSIS, 1995, 36 (03): : 255 - 258
  • [34] Closure of Large Patent Ductus Arteriosus in Infants
    Lin, Chu-Chuan
    Hsieh, Kai-Sheng
    Huang, Ta-Cheng
    Weng, Ken-Pen
    AMERICAN JOURNAL OF CARDIOLOGY, 2009, 103 (06): : 857 - 861
  • [35] Patent ductus arteriosus with persistent pulmonary artery hypertension after transcatheter closure
    Feng, Jianqi
    Kong, Xiangqing
    Sheng, Yanhui
    Yang, Rong
    THERAPEUTICS AND CLINICAL RISK MANAGEMENT, 2016, 12 : 1609 - 1613
  • [36] A NEW DEVICE FOR TRANSCATHETER CLOSURE OF THE PATENT DUCTUS-ARTERIOSUS - A FEASIBILITY STUDY IN DOGS
    MAGAL, C
    WRIGHT, KC
    DUPRAT, G
    WALLACE, S
    GIANTURCO, C
    INVESTIGATIVE RADIOLOGY, 1989, 24 (04) : 272 - 276
  • [37] Transcatheter patent ductus arteriosus closure in preterm infants: Appropriate device selection is primordial
    Baruteau, Alban-Elouen
    Fraisse, Alain
    INTERNATIONAL JOURNAL OF CARDIOLOGY, 2020, 316 : 108 - 109
  • [38] Cardiac Reverse Remodeling After Transcatheter Patent Ductus Arteriosus Closure in Adults
    Khajali, Zahra
    Firouzi, Ata
    Shakerian, Farshad
    Alemzadeh-Ansari, Mohammad Javad
    Ghobadi, Ebrahim
    Khalilipur, Ehsan
    Khalili, Yasaman
    Rezaei, Ladan
    Hosseini, Zahra
    CURRENT PROBLEMS IN CARDIOLOGY, 2022, 47 (10)
  • [39] Transcatheter closure of patent ductus arteriosus using self-expandable amplatzer device
    Arora, R
    Kalra, GS
    Singh, S
    Passey, R
    Sinha, S
    Nigam, M
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2000, 35 (02) : 499A - 499A
  • [40] TRANSCATHETER CLOSURE OF A PATENT DUCTUS-ARTERIOSUS WITH AN ADJUSTABLE BUTTONED DEVICE IN AN ADULT PATIENT
    LOCHAN, R
    RAO, PS
    SAMAL, AK
    KHANNA, AR
    MANI, GK
    GROVER, DN
    AMERICAN HEART JOURNAL, 1994, 127 (04) : 941 - 943