ANALYSIS AND DESIGN OF AN INTEGRATED SILICON ARROW MACH-ZEHNDER MICROMECHANICAL INTERFEROMETER

被引:12
|
作者
VADEKAR, A
NATHAN, A
HUANG, WP
机构
[1] Department of Electrical and Computer Engineering, University of Waterloo, Waterloo, Ontario
关键词
D O I
10.1109/50.265748
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
An analysis and design procedure for an integrated silicon micromechanical (pressure sensitive) interferometer is presented. Optimized layer thicknesses of an SiO2/Si3N4/SiO2/Si ARROW yield an attenuation of only 2.7 X 10(-3) dB/cm. Lateral confinement is accomplished with a rib in the core layer. Sensitivity to mechanical measurands is achieved by having the sensing arm of the interferometer on a thin silicon diaphragm, realized by micromachining a cavity from the back of the wafer. An applied pressure P deflects the diaphragm, causing a change in optical path length, leading to a phase shift phi with respect to the reference arm. Sensitivity is increased by thinning the diaphragm, although this increases the resonant attenuation envelope of the diaphragm. Sensitivity calculations based on a simple, first-order model of diaphragm deflection yield (partial derivative phi)/(phi partial derivative P) = 1.29 x 10(-14) P for a specific diaphragm geometry. BPM simulations show that curvature losses due to the bending of the ARROW under deflection is negligible.
引用
下载
收藏
页码:157 / 162
页数:6
相关论文
共 50 条
  • [41] Error analysis for a Mach-Zehnder type speckle interferometer
    Picart, P
    OPTICS AND LASERS IN ENGINEERING, 2001, 35 (06) : 335 - 353
  • [42] Silicon-based integrated Mach-Zehnder interferometer with acoustooptic modulation: look for a biosensor application
    Gorecki, C
    Bonnotte, E
    Worhoff, K
    Kawakatsu, H
    OPTOELECTRONIC MATERIALS AND DEVICES, 1998, 3419 : 417 - 424
  • [43] MACH-ZEHNDER TYPE OF ULTRASONIC INTERFEROMETER
    TURNER, WR
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 1964, 36 (05): : 1040 - &
  • [44] Coherence and contextuality in a Mach-Zehnder interferometer
    Wagner, Rafael
    Camillini, Anita
    Galvao, Ernesto F.
    QUANTUM, 2024, 8
  • [45] Polarization characterization of a Mach-Zehnder interferometer
    Mabrouki, A
    Gadonna, M
    LeNaour, R
    APPLIED OPTICS, 1996, 35 (19): : 3591 - 3596
  • [46] SPECTRAL CHANGES IN THE MACH-ZEHNDER INTERFEROMETER
    AGARWAL, GS
    JAMES, DFV
    JOURNAL OF MODERN OPTICS, 1993, 40 (08) : 1431 - 1436
  • [47] INITIAL ADJUSTMENT OF THE MACH-ZEHNDER INTERFEROMETER
    PRICE, EW
    REVIEW OF SCIENTIFIC INSTRUMENTS, 1952, 23 (04): : 162 - 162
  • [48] Generation of Ultrafast Bright and Dark Pulse on Silicon Chip with Integrated Mach-Zehnder Interferometer Configuration
    Wu, Jianwei
    Luo, Fengguang
    TURKISH JOURNAL OF PHYSICS, 2009, 33 (02): : 101 - 108
  • [49] Analysis and design of optimal demultiplexer based on Mach-Zehnder interferometer for CWDM application
    Cholan, Noran Azizan
    Talib, Rahmat
    Othman, Maisara
    Abdullah, Jiwa
    Siang, Teo Chun
    Ngajikin, Nor Hafizah
    2008 INTERNATIONAL CONFERENCE ON COMPUTER AND COMMUNICATION ENGINEERING, VOLS 1-3, 2008, : 423 - +
  • [50] Mach-Zehnder interferometer for movement monitoring
    Vasinek, Vladimir
    Cubik, Jakub
    Kepak, Stanislav
    Doricak, Jan
    Latal, Jan
    Koudelka, Petr
    FIBER OPTIC SENSORS AND APPLICATIONS IX, 2012, 8370