TIME-RESOLVED LIQUID SCINTILLATION-COUNTING

被引:2
|
作者
KESSLER, M
机构
关键词
D O I
10.1017/S0033822200013047
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
Historically, scientists who perform low-level measurements of 14C for age dating, and 3H2O for environmental contamination, have purchased or constructed highly specialized instruments to quantitate low-level radionuclides using a general-purpose liquid-scintillation analyzer (LSA). The LSA uses special time-resolved 3-D spectrum analysis (TR-LSC) to reduce background without substantially affecting sample counting efficiency. This technique, in combination with a special slow fluor scintillating plastic, further reduces the minimal detectable limit for the TR-LSC liquid scintillation counter. -Author
引用
收藏
页码:381 / 386
页数:6
相关论文
共 50 条
  • [41] PMP, A NOVEL SOLUTE FOR LIQUID AND PLASTIC SCINTILLATION-COUNTING
    GUSTEN, H
    [J]. INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1983, 34 (04): : 681 - 681
  • [42] ANOMALOUS LIQUID SCINTILLATION-COUNTING OF CHROMIUM-51
    CHARIG, A
    BLAKEHASKINS, J
    EIGEN, E
    [J]. ANALYTICAL BIOCHEMISTRY, 1985, 151 (02) : 428 - 430
  • [43] EFFECTS OF PERMEABILITY OF POLYETHYLENE VIALS IN LIQUID SCINTILLATION-COUNTING
    NEAME, KD
    [J]. INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1975, 26 (6-7): : 393 - 397
  • [44] TRIPLE LABEL DPM DETERMINATIONS BY LIQUID SCINTILLATION-COUNTING
    HORROCKS, DL
    [J]. TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1982, 43 : 39 - 41
  • [45] ALPHA-LIQUID SCINTILLATION-COUNTING FOR THE DETERMINATION OF PLUTONIUM
    MANOLKAR, RB
    CHANDER, K
    MARATHE, SG
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY-ARTICLES, 1994, 177 (02): : 373 - 380
  • [46] USING SIS TO COMPUTE DPM BY LIQUID SCINTILLATION-COUNTING
    RING, JG
    EVERETT, LJ
    [J]. TRANSACTIONS OF THE AMERICAN NUCLEAR SOCIETY, 1982, 43 : 38 - 39
  • [47] EFFICIENT INEXPENSIVE MULTISLEEVE LIQUID SCINTILLATION-COUNTING SYSTEM
    TRUSH, MA
    VANDYKE, K
    [J]. MICROCHEMICAL JOURNAL, 1976, 21 (01) : 70 - 74
  • [48] INSTABILITY OF LIQUID SCINTILLATION-COUNTING DUE TO SAMPLE SORPTION TO COUNTING VIAL
    TYKVA, R
    PODRACKA, E
    [J]. INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1975, 26 (08): : 495 - 498
  • [49] EFFECT OF VOLUME AND QUENCHING ON ESTIMATION OF COUNTING EFFICIENCIES IN LIQUID SCINTILLATION-COUNTING
    KNOCHE, HW
    PARKHURST, AM
    TAM, SW
    [J]. INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1979, 30 (01): : 45 - 49
  • [50] OBSERVATIONS IN THE PERFORMANCE OF ESP AND H= IN LIQUID SCINTILLATION-COUNTING
    MCQUARRIE, SA
    WIEBE, LI
    EDISS, C
    [J]. INTERNATIONAL JOURNAL OF APPLIED RADIATION AND ISOTOPES, 1980, 31 (01): : 12 - 13