Design Optimization and Operating Performance of S-CO2 Brayton Cycle under Fluctuating Ambient Temperature and Diverse Power Demand Scenarios

被引:0
|
作者
YANG Jingze [1 ]
YANG Zhen [1 ]
DUAN Yuanyuan [1 ]
机构
[1] Key Laboratory for Thermal Science and Power Engineering of MOE,Beijing Key Laboratory for CO_2 Utilization and Reduction Technology,Tsinghua University
基金
北京市自然科学基金;
关键词
D O I
暂无
中图分类号
TM615 [太阳能发电];
学科分类号
0807 ;
摘要
The supercritical CO2(S-CO2) Brayton cycle is expected to replace steam cycle in the application of solar power tower system due to the attractive potential to improve efficiency and reduce costs.Since the concentrated solar power plant with thermal energy storage is usually located in drought area and used to provide a dispatchable power output,the S-CO2Brayton cycle has to operate under fluctuating ambient temperature and diverse power demand scenarios.In addition,the cycle design condition will directly affect the off-design performance.In this work,the combined effects of design condition,and distributions of ambient temperature and power demand on the cycle operating performance are analyzed,and the off-design performance maps are proposed for the first time.A cycle design method with feedback mechanism of operating performance under varied ambient temperature and power demand is introduced innovatively.Results show that the low design value of compressor inlet temperature is not conductive to efficient operation under low loads and sufficient output under high ambient temperatures.The average yearly efficiency is most affected by the average power demand,while the load cover factor is significantly influenced by the average ambient temperature.With multi-objective optimization,the optimal solution of designed compressor inlet temperature is close to the minimum value of35℃ in Delingha with low ambient temperature,while reaches 44.15℃ in Daggett under the scenario of high ambient temperature,low average power demand,long duration and large value of peak load during the peak temperature period.If the cycle designed with compressor inlet temperature of 35℃ instead of 44.15℃ in Daggett under light industry power demand,the reduction of load cover factor will reach 0.027,but the average yearly efficiency can barely be improved.
引用
收藏
页码:190 / 206
页数:17
相关论文
共 50 条
  • [31] Comparative performance assessment of solar dish assisted s-CO2 Brayton cycle using nanofluids
    Khan, Muhammad Sajid
    Abid, Muhammad
    Ali, Hafiz Muhammad
    Amber, Khuram Pervez
    Bashir, Muhammad Anser
    Javed, Samina
    APPLIED THERMAL ENGINEERING, 2019, 148 : 295 - 306
  • [32] COST AND PERFORMANCE TRADEOFFS OF ALTERNATIVE SOLAR-DRIVEN S-CO2 BRAYTON CYCLE CONFIGURATIONS
    Ho, Clifford K.
    Carlson, Matthew
    Garg, Pardeep
    Kumar, Pramod
    PROCEEDINGS OF THE ASME 9TH INTERNATIONAL CONFERENCE ON ENERGY SUSTAINABILITY, 2015, VOL 1, 2016,
  • [33] SIMPLE RECUPERATED S-CO2 CYCLE REVISITED: OPTIMIZATION OF OPERATING PARAMETERS FOR MAXIMUM CYCLE EFFICIENCY
    Dutta, Anchit
    Gupta, Adhip
    Sathish, Sharath
    Bandooni, Aman
    Kumar, Pramod
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, 2019, VOL 9, 2019,
  • [34] Design and Performance Optimization of Partial Heating S-CO2 Power Cycle Driven by Waste Gas Heat of Main Engine
    Jiang, Yuemao
    Wang, Zhe
    Xia, Rui
    Ma, Yue
    Han, Fenghui
    Ji, Yulong
    Kung Cheng Je Wu Li Hsueh Pao/Journal of Engineering Thermophysics, 2022, 43 (09): : 2347 - 2356
  • [35] Study on CO2 - water printed circuit heat exchanger performance operating under various CO2 phases for S-CO2 power cycle application
    Baik, Seungjoon
    Kim, Seong Gu
    Lee, Jekyoung
    Lee, Jeong Ik
    APPLIED THERMAL ENGINEERING, 2017, 113 : 1536 - 1546
  • [36] Reheat-Air Brayton Combined Cycle Power Conversion Design and Performance Under Nominal Ambient Conditions
    Andreades, Charalampos
    Scarlat, Raluca O.
    Dempsey, Lindsay
    Peterson, Per
    JOURNAL OF ENGINEERING FOR GAS TURBINES AND POWER-TRANSACTIONS OF THE ASME, 2014, 136 (06):
  • [37] Integration of S-CO2 Brayton cycle and coal-fired boiler: Thermal-hydraulic analysis and design
    Fan, Y. H.
    Tang, G. H.
    Yang, D. L.
    Li, X. L.
    Wang, S. Q.
    ENERGY CONVERSION AND MANAGEMENT, 2020, 225 (225)
  • [38] Design, optimisation and evaluation of the S-CO2 Brayton cycle for marine low-speed engine flue gas
    Xie, Liangtao
    Yang, Jianguo
    Yang, Xin
    Qin, Zheng
    Sun, Sicong
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 61
  • [39] A systematic comparison of different S-CO2 Brayton cycle layouts based on multi-objective optimization for applications in solar power tower plants
    Wang, Kun
    Li, Ming-Jia
    Guo, Jia-Qi
    Li, Peiwen
    Liu, Zhan-Bin
    APPLIED ENERGY, 2018, 212 : 109 - 121
  • [40] Performance of S-CO2 Brayton Cycle and Organic Rankine Cycle(ORC) Combined System Considering the Diurnal Distribution of Solar Radiation
    GAO Wei
    YAO Mingyu
    CHEN Yong
    LI Hongzhi
    ZHANG Yifan
    ZHANG Lei
    JournalofThermalScience, 2019, 28 (03) : 463 - 471