Absolute quantification in SPECT

被引:0
|
作者
Philipp Ritt
Hans Vija
Joachim Hornegger
Torsten Kuwert
机构
[1] Friedrich-Alexander-Universität Erlangen-Nürnberg,Clinic of Nuclear Medicine
[2] Siemens Medical Solutions,Department of Pattern Recognition
[3] Friedrich-Alexander-Universität Erlangen-Nürnberg,undefined
关键词
SPECT; SPECT/CT; Hybrid imaging; Dosimetry; Quantification; Absolute quantification;
D O I
暂无
中图分类号
学科分类号
摘要
Single-photon emission computed tomography (SPECT) allows the three-dimensional visualization of radioactivity within the human body and is widely used for clinical purposes. In SPECT, image quality is compromised by several factors including photon attenuation, photon scatter, the partial volume effect, and motion artefacts. These variables also confound the capacity of SPECT to quantify the concentration of radioactivity within given volumes of interest in absolute units, e.g. as kilobecquerels per cubic centimetre. In the last decade, considerable technical progress has been achieved in SPECT image reconstruction, involving, in particular, the development of iterative image reconstruction techniques. Furthermore, hybrid cameras integrating a SPECT camera with an X-ray CT scanner have become commercially available. These systems allow the acquisition of SPECT and CT datasets registered to each other with a high anatomical accuracy. First studies have shown that iterative SPECT image reconstruction techniques incorporating information from SPECT/CT image datasets greatly increase the accuracy of SPECT in quantifying radioactivity concentrations in phantoms and also in humans. This new potential of SPECT may improve not only diagnostic accuracy, but also dosimetry for internal radiotherapy.
引用
下载
收藏
页码:69 / 77
页数:8
相关论文
共 50 条
  • [31] Towards standardization of absolute SPECT/CT quantification: a multi-center and multi-vendor phantom study
    Steffie M. B. Peters
    Niels R. van der Werf
    Marcel Segbers
    Floris H. P. van Velden
    Roel Wierts
    Koos (J.) A. K. Blokland
    Mark W. Konijnenberg
    Sergiy V. Lazarenko
    Eric P. Visser
    Martin Gotthardt
    EJNMMI Physics, 6
  • [32] Absolute quantification of regional myocardial uptake of 99mTc-Sestamibi with SPECT:: Experimental validation in a porcine model
    Da Silva, AJ
    Tang, HR
    Wong, KH
    Wu, MC
    Dae, MW
    Hasegawa, BH
    JOURNAL OF NUCLEAR MEDICINE, 2001, 42 (05) : 772 - 779
  • [33] Evaluating stress and rest absolute quantification of uptake in myocardial perfusion SPECT using GE Q.Metrix
    Armstrong, I.
    Fyfe, N.
    Arumugam, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S335 - S335
  • [34] Quantification in SPECT cardiac imaging
    Iida, H
    Hayashi, T
    Eberl, S
    Saji, H
    JOURNAL OF NUCLEAR MEDICINE, 2003, 44 (01) : 40 - 42
  • [35] Reproducibility Of DAT SPECT Quantification
    Wichert-Ana, L.
    Alexandre-Santos, L. W.
    Trevisan, A. C.
    Itikawa, E. N.
    Pitella, F. A.
    Kato, M.
    Simoes, M. V.
    Tumas, V.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2017, 44 : S627 - S627
  • [36] Quantification of Myocardial Perfusion: SPECT
    Petretta M.
    Cuocolo R.
    Acampa W.
    Cuocolo A.
    Current Cardiovascular Imaging Reports, 2012, 5 (3) : 144 - 150
  • [37] Quantification of PET and SPECT biomarkers
    Saffer, J.
    MEDICAL PHYSICS, 2007, 34 (06) : 2556 - 2556
  • [38] SPECT Image Quality and Quantification
    Wieczorek, Herfried
    2006 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOL 1-6, 2006, : 2854 - 2858
  • [39] Absolute Quantification of RXRG isoforms
    Skotarczak, Teagan
    Karnath, Erin
    Monin, Lydia
    Shimanovich, Yana
    Bistulfi, Gala
    FASEB JOURNAL, 2017, 31
  • [40] Absolute SPECT/CT quantification of cerebral uptake of Tc-99m-HMPAO for patients with cognitive disturbance.
    Welz, F.
    Cachovan, M.
    Maler, J. M.
    Kornhuber, J.
    Kuwert, T.
    Ritt, P.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2014, 41 : S367 - S367