Imageless navigation system (Naviswiss) provides accurate component position in total hip arthroplasty with lateral decubitus position for end-stage hip osteoarthritis: a prospective cohort study with CT-validation

被引:0
|
作者
Corey J. Scholes
Manaal Fatima
Tobias Schwagli
David Liu
机构
[1] EBM Analytics,
[2] Medivation,undefined
[3] Gold Coast Centre for Bone and Joint Surgery,undefined
来源
关键词
Hip arthroplasty; Imageless navigation; Lateral decubitus; Validation;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 17 条
  • [1] Imageless navigation system (Naviswiss) provides accurate component position in total hip arthroplasty with lateral decubitus position for end-stage hip osteoarthritis: a prospective cohort study with CT-validation
    Scholes, Corey J.
    Fatima, Manaal
    Schwagli, Tobias
    Liu, David
    ARTHROPLASTY, 2024, 6 (01)
  • [2] CT validation of intraoperative imageless navigation (Naviswiss) for component positioning accuracy in primary total hip arthroplasty in supine patient position: a prospective observational cohort study in a single-surgeon practice
    Scholes, Corey
    Schwagli, Tobias
    Ireland, John
    ARTHROPLASTY, 2023, 5 (01)
  • [3] CT validation of intraoperative imageless navigation (Naviswiss) for component positioning accuracy in primary total hip arthroplasty in supine patient position: a prospective observational cohort study in a single-surgeon practice
    Corey Scholes
    Tobias Schwagli
    John Ireland
    Arthroplasty, 5
  • [4] A novel imageless accelerometer-based navigation system improves acetabular cup placement accuracy during total hip arthroplasty in the lateral decubitus position
    Ohyama, Yohei
    Minoda, Yukihide
    Sugama, Ryo
    Masuda, Sho
    Ohta, Yoichi
    Nakamura, Hiroaki
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2024, 144 (06) : 2865 - 2872
  • [5] Accurate cup placement using a portable navigation system during total hip arthroplasty based on pelvic orientation in the lateral decubitus position
    Tsukamoto, Manabu
    Kawasaki, Makoto
    Suzuki, Hitoshi
    Fujitani, Teruaki
    Uchida, Soshi
    Sakai, Akinori
    ARTIFICIAL ORGANS, 2022, 46 (12) : 2412 - 2422
  • [6] Validity of intraoperative imageless navigation (Naviswiss) for component positioning accuracy in primary total hip arthroplasty: protocol for a prospective observational cohort study in a single-surgeon practice
    Ektas, Nalan
    Scholes, Corey
    Ruiz, Alejandro M.
    Ireland, John
    BMJ OPEN, 2020, 10 (10):
  • [7] Fluoroscopy-guided direct anterior approach total hip arthroplasty provides more accurate component positions in the supine position than in the lateral position
    Penglei Chen
    Wangxin Liu
    Cong Wu
    Pengfei Ruan
    Jicheng Zeng
    Weifeng Ji
    BMC Musculoskeletal Disorders, 24
  • [8] Fluoroscopy-guided direct anterior approach total hip arthroplasty provides more accurate component positions in the supine position than in the lateral position
    Chen, Penglei
    Liu, Wangxin
    Wu, Cong
    Ruan, Pengfei
    Zeng, Jicheng
    Ji, Weifeng
    BMC MUSCULOSKELETAL DISORDERS, 2023, 24 (01)
  • [9] Portable imageless navigation system and surgeon’s estimate for accurate evaluation of acetabular cup orientation during total hip arthroplasty in supine position
    Ryohei Takada
    Tetsuya Jinno
    Kazumasa Miyatake
    Masanobu Hirao
    Toshitaka Yoshii
    Atsushi Okawa
    European Journal of Orthopaedic Surgery & Traumatology, 2020, 30 : 707 - 712
  • [10] Portable imageless navigation system and surgeon's estimate for accurate evaluation of acetabular cup orientation during total hip arthroplasty in supine position
    Takada, Ryohei
    Jinno, Tetsuya
    Miyatake, Kazumasa
    Hirao, Masanobu
    Yoshii, Toshitaka
    Okawa, Atsushi
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2020, 30 (04): : 707 - 712