Validity of intraoperative imageless navigation (Naviswiss) for component positioning accuracy in primary total hip arthroplasty: protocol for a prospective observational cohort study in a single-surgeon practice

被引:10
|
作者
Ektas, Nalan [1 ]
Scholes, Corey [1 ]
Ruiz, Alejandro M. [2 ]
Ireland, John [3 ,4 ]
机构
[1] EBM Analyt, Sydney, NSW, Australia
[2] Act Surg, Sydney, NSW, Australia
[3] Sydney Bone & Joint Clin, Sydney, NSW, Australia
[4] Univ Wollongong, Sch Med, Wollongong, NSW, Australia
来源
BMJ OPEN | 2020年 / 10卷 / 10期
关键词
hip; orthopaedic & trauma surgery; adult orthopaedics; musculoskeletal disorders; ACETABULAR COMPONENT; COMPUTER NAVIGATION; LEG LENGTH; OFFSET; RELIABILITY;
D O I
10.1136/bmjopen-2020-037126
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Introduction Optimal outcomes in total hip arthroplasty (THA) are dependent on appropriate placement of femoral and acetabular components, with technological advances providing a platform for guiding component placement to reduce the risk of malpositioned components during surgery. This study will validate the intraoperative data captured using a handheld imageless THA navigation system against postoperative measurements of acetabular inclination, acetabular version, leg length and femoral offset on CT radiographs. Methods and analysis This is a prospective observational cohort study conducted within a single-centre, single-surgeon private practice. Data will be collected for 35 consecutive patients (>18 years) undergoing elective THA surgery, from the research registry established at the surgeon's practice. The primary outcome is the agreement between intraoperative component positioning data captured by the navigation system compared with postoperative measurements using CT. A total of ten CT scans will be reassessed for interobserver and intraobserver reliability. The influence of patient and surgical factors on the accuracy of component position will also be examined with multivariable linear regression. Ethics and dissemination Ethics approval for this study was provided through a certified ethics committee (Bellberry HREC approval number 2017-07-499). The results of this study will be disseminated through peer-reviewed journals and conference presentations.
引用
收藏
页数:7
相关论文
共 14 条
  • [1] CT validation of intraoperative imageless navigation (Naviswiss) for component positioning accuracy in primary total hip arthroplasty in supine patient position: a prospective observational cohort study in a single-surgeon practice
    Scholes, Corey
    Schwagli, Tobias
    Ireland, John
    ARTHROPLASTY, 2023, 5 (01)
  • [2] CT validation of intraoperative imageless navigation (Naviswiss) for component positioning accuracy in primary total hip arthroplasty in supine patient position: a prospective observational cohort study in a single-surgeon practice
    Corey Scholes
    Tobias Schwagli
    John Ireland
    Arthroplasty, 5
  • [3] Evaluation of Component Positioning in Primary Total Hip Arthroplasty Using an Imageless Navigation Device Compared With Traditional Methods
    Najarian, Brian C.
    Kilgore, John E.
    Markel, David C.
    JOURNAL OF ARTHROPLASTY, 2009, 24 (01): : 15 - 21
  • [4] Imageless navigation system (Naviswiss) provides accurate component position in total hip arthroplasty with lateral decubitus position for end-stage hip osteoarthritis: a prospective cohort study with CT-validation
    Scholes, Corey J.
    Fatima, Manaal
    Schwagli, Tobias
    Liu, David
    ARTHROPLASTY, 2024, 6 (01)
  • [5] Imageless navigation system (Naviswiss) provides accurate component position in total hip arthroplasty with lateral decubitus position for end-stage hip osteoarthritis: a prospective cohort study with CT-validation
    Corey J. Scholes
    Manaal Fatima
    Tobias Schwagli
    David Liu
    Arthroplasty, 6
  • [6] Improved accuracy of glenoid positioning in total shoulder arthroplasty with intraoperative navigation: A prospective-randomized clinical study
    Kircher, Joern
    Wiedemann, Markus
    Magosch, Petra
    Lichtenberg, Sven
    Habermeyer, Peter
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2009, 18 (04) : 515 - 520
  • [7] Use of augmented reality surgical navigation reduces intraoperative fluoroscopic imaging in anterior total hip arthroplasty with equivalent accuracy for component positioning
    Coden, Gloria
    Kuznetsov, Mikhail
    Schoeller, Lauren
    Patti, James
    Grant, Andrew
    Miller, James Penn
    Talmo, Carl
    JOURNAL OF ORTHOPAEDICS, 2025, 68 : 15 - 19
  • [8] Enhancing the accuracy of cup placement in total hip arthroplasty using CT-based navigation by a trainee surgeon: a retrospective cohort study
    Tachibana, Tetsuya
    Katagiri, Hiroki
    Ogawa, Takahisa
    Koyano, Gaku
    Jinno, Tetsuya
    BMC MUSCULOSKELETAL DISORDERS, 2025, 26 (01)
  • [9] Accuracy of the Imageless Mode of the ROSA Robotic System for Targeted Resection Thickness in Total Knee Arthroplasty: A Prospective, Single Surgeon Case-Series Study
    Gamie, Zakareya
    Kenanidis, Eustathios
    Douvlis, Georgios
    Mylonakis, Nikolaos
    Maslaris, Alexander
    Tsiridis, Eleftherios
    INTERNATIONAL JOURNAL OF MEDICAL ROBOTICS AND COMPUTER ASSISTED SURGERY, 2024, 20 (06):
  • [10] Intraoperative navigation system use increases accuracy of glenoid component inclination but not functional outcomes in reverse total shoulder arthroplasty: a prospective comparative study
    Gaj, Edoardo
    Pagnotta, Susanna M.
    Berlinberg, Elyse J.
    Patel, Harsh H.
    Picconi, Orietta
    Redler, Andrea
    De Carli, Angelo
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2023, 144 (1) : 91 - 102