Whole-body PET scanner produces 3D images in seconds

被引:0
|
作者
Sara Reardon
机构
来源
Nature | 2019年 / 570卷
关键词
Medical research; Physiology; Biological techniques; Cancer;
D O I
暂无
中图分类号
学科分类号
摘要
The modified scanner also requires less radioactive exposure, vastly broadening its applications.
引用
收藏
页码:285 / 286
页数:1
相关论文
共 50 条
  • [1] Whole-body 3D MR angiography in 72 seconds
    Herborn, CU
    Goyen, M
    Bosk, S
    Kroeger, K
    Debatin, JF
    Ruehm, SG
    [J]. RADIOLOGY, 2001, 221 : 264 - 264
  • [2] Whole-body 3D scanner and scan data report
    Addleman, S
    [J]. THREE-DIMENSIONAL IMAGE CAPTURE, 1997, 3023 : 2 - 5
  • [3] Evaluation of the count recovery coefficient of a whole-body PET/CT scanner in 3D mode image
    Tsujikawa, T.
    Okazawa, H.
    Ohtsuka, H.
    Morita, N.
    Nishitani, H.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2006, 33 : S313 - S313
  • [4] Reliability of the Styku 3D Whole-Body Scanner for the Assessment of Body Size in Athletes
    Derouchey, Joe D.
    Tomkinson, Grant R.
    Rhoades, Jesse L.
    Fitzgerald, John S.
    [J]. MEASUREMENT IN PHYSICAL EDUCATION AND EXERCISE SCIENCE, 2020, 24 (03) : 228 - 234
  • [5] An effective scatter correction method based on single scatter simulation for a 3D whole-body PET scanner
    高飞
    Yamada Ryoko
    Watanabe Mitsuo
    刘华锋
    [J]. Chinese Physics B, 2009, 18 (07) : 3066 - 3072
  • [6] An effective scatter correction method based on single scatter simulation for a 3D whole-body PET scanner
    Gao Fei
    Ryoko, Yamada
    Mitsuo, Watanabe
    Liu Hua-Feng
    [J]. CHINESE PHYSICS B, 2009, 18 (07) : 3066 - 3072
  • [7] Clinical evaluation of 2D versus 3D whole-body PET image quality using a dedicated BGO PET scanner
    D. Visvikis
    D. Griffiths
    D. C. Costa
    J. Bomanji
    P. J. Ell
    [J]. European Journal of Nuclear Medicine and Molecular Imaging, 2005, 32 : 1050 - 1056
  • [8] Clinical evaluation of 2D versus 3D whole-body PET image quality using a dedicated BGO PET scanner
    Visvikis, D
    Griffiths, D
    Costa, DC
    Bomanji, J
    Ell, PJ
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2005, 32 (09) : 1050 - 1056
  • [9] A prototype axial shield for use in 3D whole-body PET
    Cutler, PD
    Laforest, R
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2001, 48 (01) : 10 - 15
  • [10] A Registration Method Based on Contour Point Cloud for 3D Whole-Body PET and CT Images
    Song, Zhiying
    Jiang, Huiyan
    Yang, Qiyao
    Wang, Zhiguo
    Zhang, Guoxu
    [J]. BIOMED RESEARCH INTERNATIONAL, 2017, 2017