Oscillometric versus invasive blood pressure measurement in patients with shock: a prospective observational study in the emergency department

被引:0
|
作者
Agnes S. Meidert
Michael E. Dolch
Konstanze Mühlbauer
Bernhard Zwissler
Matthias Klein
Josef Briegel
Stephan Czerner
机构
[1] University Hospital,Department of Anaesthesiology
[2] LMU Munich,Emergency Department
[3] Hospital of the LMU,Department of Neurology
[4] Hospital of the LMU,undefined
[5] Department of Anaesthesiology,undefined
关键词
Emergency medicine; Oscillometric blood pressure; Shock; Resuscitation area; Hypotension;
D O I
暂无
中图分类号
学科分类号
摘要
In emergency medicine, blood pressure is often measured by an oscillometric device using an upper arm cuff. However, measurement accuracy of this technique in patients suffering from hypotensive shock has not been sufficiently evaluated. We designed a prospective observational study investigating the accuracy of an oscillometric device in hypotensive patients admitted to the resuscitation area of the emergency department. Patients admitted to the resuscitation area of a university hospital, who were equipped with an arterial catheter and found to be hypotensive (mean arterial pressure (MAP) < 60 mmHg) were eligible for the study. Blood pressure was measured simultaneously via upper arm cuff and invasively under routine clinical conditions. After data extraction, Bland–Altman analysis, correlation coefficient and percentage error of mean and systolic blood pressure pairs were performed. We analysed 75 simultaneously obtained blood pressure measurements of 30 patients in hypotension, 11 (37%) were female, median age was 76.5 years (IQR 63–82). Oscillometric MAP was markedly higher than invasive MAP with a mean of the differences of 13 ± 15 mmHg (oscillometric—invasive), 95% limits of agreement − 16 to 41 mmHg, percentage error was 76%. In 64% of readings, values obtained by the upper arm cuff were not able to detect hypotension. Oscillometric blood pressure measurement is not able to reliably detect hypotension in emergency patients. Therefore, direct measurement of blood pressure should be established as soon as possible in patients suffering from shock.
引用
收藏
页码:387 / 393
页数:6
相关论文
共 50 条
  • [41] Non-invasive assessment of arterial stiffness using oscillometric blood pressure measurement
    Komine, Hidehiko
    Asai, Yoshiyuki
    Yokoi, Takashi
    Yoshizawa, Mutsuko
    BIOMEDICAL ENGINEERING ONLINE, 2012, 11
  • [42] Comparison of invasive and oscillometric blood pressure measurement techniques in anesthetized sheep, goats, and cattle
    Aarnes, Turi K.
    Hubbell, John A. E.
    Lerche, Phillip
    Bednarski, Richard M.
    VETERINARY ANAESTHESIA AND ANALGESIA, 2014, 41 (02) : 174 - 185
  • [43] Blood Pressure Measurement Compared Between Oscillometric Blood Pressure Monitoring and Gold Standard Intra-Arterial Blood Pressure Monitoring in Adult Shock Resuscitation Patients
    Tongyoo, Surat
    Visuthisakchai, Suharit
    Permpikul, Chairat
    JOURNAL OF CRITICAL & INTENSIVE CARE, 2022, 13 (03): : 102 - 109
  • [44] Accuracy of wrist cuff oscillometric blood pressure measurement in obese patients
    Wertli, M.
    Ruckstuhl, N.
    Vetter, W.
    Suter, P. M.
    JOURNAL OF HYPERTENSION, 2007, 25 : S25 - S25
  • [45] Reliability of patients measuring blood pressure at home: prospective observational study
    Nordmann, A
    Frach, B
    Walker, T
    Martina, B
    Battegay, E
    BMJ-BRITISH MEDICAL JOURNAL, 1999, 319 (7218): : 1172 - 1172
  • [46] Comparison of routine office blood pressure measurement versus standardized attended manually activated oscillometric office blood pressure measurement in patients with chronic kidney disease
    Chellappan, Anand
    Kansal, Keshiha
    JOURNAL OF FAMILY MEDICINE AND PRIMARY CARE, 2024, 13 (05) : 1894 - 1903
  • [47] Smartphone-Based versus Non-Invasive Automatic Oscillometric Brachial Cuff Blood Pressure Measurements: A Prospective Method Comparison Volunteer Study
    Delmotte, Lila
    Desebbe, Olivier
    Alexander, Brenton
    Kouz, Karim
    Coeckelenbergh, Sean
    Schoettker, Patrick
    Turgay, Tuna
    Joosten, Alexandre
    JOURNAL OF PERSONALIZED MEDICINE, 2024, 14 (01):
  • [48] Prospective, observational study investigating the level of agreement between transcutaneous and invasive carbon dioxide measurements in critically ill emergency department patients
    Farenden, Scott
    Chung, Yewon
    Cui, Amy
    Ferguson, Ian
    EMERGENCY MEDICINE JOURNAL, 2023, 40 (09) : 646 - 650
  • [49] Use of a smartphone camera to estimate systolic blood pressure compared to standard oscillometric blood pressure measurement a prospective trial
    Eckstein, J.
    Burkardt, T.
    Winterhalder, C.
    Leonardi, L.
    Thommen, E.
    Weber, S.
    Birkemeyer, R.
    Seeck, A.
    Koenig, N.
    Doerr, M.
    EUROPEAN HEART JOURNAL, 2017, 38 : 61 - 61
  • [50] Elevated blood pressure in urban emergency department patients
    Karras, DJ
    Ufberg, JW
    Heilpern, KL
    Cienki, JJ
    Chiang, WK
    Wald, MM
    Harrigan, RA
    Wald, DA
    Shayne, P
    Gaughan, J
    Kruus, LK
    ACADEMIC EMERGENCY MEDICINE, 2005, 12 (09) : 835 - 843