Carbon dioxide (CO2) digital subtraction angiography: 26-year experience at the University of Florida

被引:0
|
作者
I. F. Hawkins
J. G. Caridi
机构
[1] Division of Interventional Radiology,
[2] Health Science Center,undefined
[3] University of Florida,undefined
[4] P. O. Box 100374,undefined
[5] Gainsville,undefined
[6] FL 32610–0374,undefined
[7] USA,undefined
来源
European Radiology | 1998年 / 8卷
关键词
Key words: Contrast; Carbon dioxide (CO2); Digital subtraction angiography;
D O I
暂无
中图分类号
学科分类号
摘要
Although the vascular system is presently being imaged by multiple high technology modalities, contrast angiography continues to be the gold standard; however, severe complications rarely occur. During the last 25 years (in over 1400 patients), CO2 has proven to be extremely safe (no allergy or renal failure). However, it is imperative to understand CO2's physical properties and potential dangers. Recently, CO2 is being routinely utilized not only because of safety, but for detection of minute amounts of bleeding, better collateral filling, and for most interventional procedures since unlimited volumes of CO2 can be injected between the catheter and guidewire. Presently, safe, reliable and “user-friendly” delivery systems are now commercially available. CO2 DSA images are now nearly comparable to iodinated contrast, and improvement in DSA images are evolving, including “stacking” software.
引用
收藏
页码:391 / 402
页数:11
相关论文
共 50 条
  • [21] Carbon dioxide digital subtraction angiography using a new gas management system
    SchmitzRode, T
    Alzen, G
    Gunther, RW
    [J]. ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 1997, 167 (01): : 71 - 78
  • [22] CEREBRAL-ANGIOGRAPHY WITH GASEOUS CARBON-DIOXIDE CO2
    SHIFRIN, EG
    PLICH, MB
    VERSTANDIG, AG
    GOMORI, M
    [J]. JOURNAL OF CARDIOVASCULAR SURGERY, 1990, 31 (05): : 603 - 606
  • [23] CO2 digital subtraction angiography for renal artery angioplasty in high-risk patients
    Caridi, JG
    Stavropoulos, SW
    Hawkins, IF
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 1999, 173 (06) : 1551 - 1556
  • [24] Digital subtraction angiography using CO2 as a contrast agent: The effect of kVp on image contrast
    Ogden, KM
    Mewissen, MW
    Wilson, CR
    [J]. RADIOLOGY, 1997, 205 : 904 - 904
  • [25] RETROGRADE VISUALIZATION OF THE PORTAL VENOUS SYSTEM USING CO2 INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY
    MIYAZONO, N
    INOUE, H
    KANETSUKI, I
    NAKAJO, M
    [J]. ABDOMINAL IMAGING, 1994, 19 (04): : 330 - 332
  • [26] CO2 as an intra-arterial digital subtraction angiography (IADSA) agent in the management of trauma
    Hashimoto, S
    Hiramatsu, K
    Sato, M
    [J]. SEMINARS IN INTERVENTIONAL RADIOLOGY, 1997, 14 (02) : 163 - 173
  • [27] INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY WITH CARBON-DIOXIDE - SUPERIOR DETECTABILITY OF ARTERIOVENOUS SHUNTING
    TAKEDA, T
    IDO, K
    YUASA, Y
    NISHIMURA, G
    HASHIMOTO, S
    KYO, E
    OKAWA, S
    NAKATSUKA, S
    MIURA, H
    KOBAYASHI, S
    TANAKA, T
    HIRAMATSU, K
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 1988, 11 (02) : 101 - 107
  • [28] Use of a compression paddle to displace bowel gas for carbon dioxide digital subtraction angiography
    Stram, ES
    Molgaard, CP
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 1999, 10 (04) : 405 - 408
  • [30] USE OF CARBON-DIOXIDE AS A CONTRAST-MEDIUM DURING INTRAARTERIAL DIGITAL SUBTRACTION ANGIOGRAPHY
    YUSUF, SW
    WHITAKER, SC
    GREGSON, RH
    HINDWOOD, D
    WENHAM, PW
    HOPKINSON, BR
    MAKIN, GS
    [J]. BRITISH JOURNAL OF SURGERY, 1994, 81 (04) : 610 - 610