Dosimetric Comparisons of Intensity-Modulated Radiotherapy, Volumetric Modulated Arc Therapy, Tomotherapy, Stereotactic Radiosurgery, and Proton Therapy for Treatment of Patients with a Vestibular Schwannoma

被引:0
|
作者
Yoonjin Oh
Dong Oh Shin
Moonkyoo Kong
Dong Ho Shin
Weon Kuu Chung
Dong Wook Kim
机构
[1] Sungkyunkwan University School of Medicine,Department of Radiation Oncology, Samsung Medical Center
[2] Kyung Hee University Hospital,Department of Radiation Oncology
[3] Kyung Hee University School of Medicine,Department of Radiation Oncology, Kyung Hee University Medical Center
[4] National Cancer Center,Proton Therapy Center
[5] Kyung Hee University Hospital at Gangdong,Department of Radiation Oncology
[6] Yonsei University College of Medicine,Department of Radiation Oncology, Yonsei Cancer Center
来源
关键词
IMRT; VMAT; SRS; Proton therapy; Tomotherapy; Dosimetric index;
D O I
暂无
中图分类号
学科分类号
摘要
This study compares the dosimetric characteristics of radiotherapy treatment methods for patients with a vestibular schwannoma. We generated and compared intensity-modulated radiotherapy (IMRT), volumetric modulated arc therapy (VMAT), tomotherapy (TOMO), and proton therapy (Proton) treatment plans among eight patients with a vestibular schwannoma who received stereotactic radiosurgery based on M3 (M3-SRS) treatment. The dose comparison of the planning target volume (PTV) was performed by calculating the homogeneity index (HI), conformity index (CI), coverage index (CVI), and equivalent uniform dose (EUD). A dose comparison for adjacent normal organs was performed by calculating the EUD and the normal tissue complication probability (NTCP). The PTV coverage showed excellent dose homogeneity and conformity on the target volume for M3-SRS treatment. The sparing of the organs at risk (OARs) was excellent in terms of dose delivery to most normal organs away from the target for Proton; however, the other modalities were also within the tolerance dose limit for the OARs. This study further confirmed the possibility of using radiotherapy, along with the use of other treatment methods, for patients with a vestibular schwannoma.
引用
收藏
页码:389 / 398
页数:9
相关论文
共 50 条
  • [21] SmartArc-Based Volumetric Modulated Arc Therapy for Endometrial Cancer: A Dosimetric Comparison with Helical Tomotherapy and Intensity-Modulated Radiation Therapy
    Yang, R.
    Wang, J.
    Xu, S.
    Li, H.
    [J]. MEDICAL PHYSICS, 2013, 40 (06)
  • [22] SmartArc-based volumetric modulated arc therapy for endometrial cancer: a dosimetric comparison with helical tomotherapy and intensity-modulated radiation therapy
    Ruijie Yang
    Junjie Wang
    Shouping Xu
    Hua Li
    [J]. BMC Cancer, 13
  • [23] SmartArc-based volumetric modulated arc therapy for endometrial cancer: a dosimetric comparison with helical tomotherapy and intensity-modulated radiation therapy
    Yang, Ruijie
    Wang, Junjie
    Xu, Shouping
    Li, Hua
    [J]. BMC CANCER, 2013, 13
  • [24] Volumetric intensity-modulated arc therapy vs conventional intensity-modulated radiation therapy in nasopharyngeal carcinoma: a dosimetric study
    White, Peter
    Chan, Kit Chi
    Cheng, Ka Wai
    Chan, Ka Yiu
    Chau, Ming Chun
    [J]. JOURNAL OF RADIATION RESEARCH, 2013, 54 (03) : 532 - 545
  • [25] Comparison of photon volumetric modulated arc therapy, intensity-modulated proton therapy, and intensity-modulated carbon ion therapy for delivery of hypo-fractionated thoracic radiotherapy
    Alexander Chi
    Lien-Chun Lin
    Sijin Wen
    Haijuan Yan
    Wen-Chien Hsi
    [J]. Radiation Oncology, 12
  • [26] Comparison of photon volumetric modulated arc therapy, intensity-modulated proton therapy, and intensity-modulated carbon ion therapy for delivery of hypo-fractionated thoracic radiotherapy
    Chi, Alexander
    Lin, Lien-Chun
    Wen, Sijin
    Yan, Haijuan
    Hsi, Wen-Chien
    [J]. RADIATION ONCOLOGY, 2017, 12
  • [27] VOLUMETRIC-MODULATED ARC THERAPY FOR STEREOTACTIC BODY RADIOTHERAPY OF LUNG TUMORS: A COMPARISON WITH INTENSITY-MODULATED RADIOTHERAPY TECHNIQUES
    Holt, Andrea
    van Vliet-Vroegindeweij, Corine
    Mans, Anton
    Belderbos, Jose S.
    Damen, Eugene M. F.
    [J]. INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2011, 81 (05): : 1560 - 1567
  • [28] Dosimetric Comparison of Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Radiotherapy for the Treatment of Multiple Intracranial Metastases
    Lin, X.
    Sun, T.
    Yin, Y.
    Liu, T.
    Lu, J.
    [J]. MEDICAL PHYSICS, 2011, 38 (06) : 3683 - +
  • [29] DOSIMETRIC COMPARISON OF INTENSITY-MODULATED RADIATION THERAPY, HELICAL TOMOTHERAPY, VOLUMETRIC MODULATED ARC THERAPY, AND 3D-CONFORMAL RADIOTHERAPY IN THE POST-OPERATIVE TREATMENT OF GASTRIC CANCER PATIENTS
    Loewen, S.
    Joseph, K.
    Usmani, N.
    Tankel, K.
    Severin, D.
    Nijjar, T.
    Warkentin, H.
    Syme, A.
    Williams, D.
    Field, C.
    [J]. RADIOTHERAPY AND ONCOLOGY, 2010, 96 : S36 - S37
  • [30] Dosimetric Comparison of Intensity-Modulated Radiotherapy and Volumetric Modulated Arc Radiotherapy for the Treatment of Multiple Intracranial Metastases
    Liu, X.
    Yin, Y.
    [J]. MEDICAL PHYSICS, 2017, 44 (06) : 2912 - 2912