A high-sensitivity drinkometer circuit with 60-Hz filtering

被引:0
|
作者
Roger L. Overton
Donald A. Overton
机构
[1] Huntington Station,Psychology Department, Weiss Hall
[2] Temple University,undefined
[3] Temple University,undefined
来源
Behavior Research Methods | 2007年 / 39卷
关键词
Power Supply Voltage; Moisture Path; Drinkometer Circuit; Tongue Contact; Relay Coil;
D O I
暂无
中图分类号
学科分类号
摘要
This article describes a drinkometer circuit designed to (1) detect licks even if the resistance of the skin on the animal’s feet becomes quite high due to low humidity, (2) automatically adjust its triggering threshold and increase its gain so that it will continue to detect licks when the water delivery spout is partially shorted to ground by high ambient humidity, (3) reject 60-Hz signals so they will not be treated as rapid licks by the data-recording system, and (4) tolerate the high voltages that can occur if the subject receives an electric shock while drinking. This lickometer will be especially useful in situations where it is not practical to monitor for possible signal failure due to high or low humidity, or where 60-Hz artifacts may contaminate the signal provided to a recording computer.
引用
收藏
页码:118 / 122
页数:4
相关论文
共 50 条
  • [31] HIGH-STRENGTH 60-HZ ELECTRIC-FIELDS ARE CIRCADIAN ZEITGEBERS IN MICE
    EHRET, PF
    DUFFY, CH
    CHRONOBIOLOGIA, 1983, 10 (02) : 124 - 124
  • [32] EFFECTS OF 2-HZ AND 60-HZ ELECTRICAL-STIMULATION ON THE MICROSTRUCTURE OF BEEF
    TAKAHASHI, G
    WANG, SM
    LOCHNER, JV
    MARSH, BB
    MEAT SCIENCE, 1987, 19 (01) : 65 - 76
  • [33] Exposures of children in Canada to 60-Hz magnetic and electric fields
    Deadman, JE
    Armstrong, BG
    McBride, ML
    Gallagher, R
    Thériault, G
    SCANDINAVIAN JOURNAL OF WORK ENVIRONMENT & HEALTH, 1999, 25 (04) : 368 - 375
  • [34] Human exposure to 60-Hz magnetic fields: neurophysiological effects
    Graham, C
    Cook, MR
    Cohen, HD
    Riffle, DW
    Hoffman, S
    Gerkovich, MM
    INTERNATIONAL JOURNAL OF PSYCHOPHYSIOLOGY, 1999, 33 (02) : 169 - 175
  • [36] Behavioral effects of strong 60-HZ electric fields in rats
    Smith, M.T.
    D'Andrea, J.A.
    Gandhi, O.P.
    Journal of Microwave Power, 1979, 14 (03): : 223 - 228
  • [37] STIMULATION OF CUTANEOUS MECHANORECEPTORS BY 60-HZ ELECTRIC-FIELDS
    WEIGEL, RJ
    JAFFE, RA
    LUNDSTROM, DL
    FORSYTHE, WC
    ANDERSON, LE
    BIOELECTROMAGNETICS, 1987, 8 (04) : 337 - 350
  • [38] DEVELOPMENTAL TOXICOLOGY STUDIES WITH 60-HZ ELECTRIC-FIELDS
    SIKOV, MR
    MONTGOMERY, LD
    HEALTH PHYSICS, 1978, 35 (06): : 890 - 891
  • [39] BIOLOGICAL EFFECTS OF 60-HZ MAGNETIC-FIELD ON MICE
    FAM, WZ
    IEEE TRANSACTIONS ON MAGNETICS, 1981, 17 (04) : 1510 - 1513
  • [40] CALIBRATION OF FLAT 60-HZ ELECTRIC-FIELD PROBES
    MISAKIAN, M
    BIOELECTROMAGNETICS, 1984, 5 (04) : 447 - 450