Measurement of k0-Factors in Prompt Gamma-Ray Neutron Activation Analysis

被引:0
|
作者
R.N. Acharya
K. Sudarshan
A.G.C. Nair
Y.M. Scindia
A. Goswami
A.V.R. Reddy
S.B. Manohar
机构
[1] Bhabha Atomic Research Centre,Radiochemistry Division
关键词
NH4Cl; Neutron Beam; HPGe Detector; Cobalt Chloride; Bhabha Atomic Research;
D O I
暂无
中图分类号
学科分类号
摘要
The guided thermal neutron beam at 100 MW Dhruva research reactor facility of Bhabha Atomic Research Centre (BARC) was used to carry out prompt gamma-ray neutron activation analysis (PGNAA). The prompt k0-factors have been determined for the isotopes of the elements H, B, K, Co, Cu, Ca, Ti, Cr, Cd, Ba, Hg and Gd with respect to 1951 keV gamma-line of 36Cl. The prompt k0-factors for H, Cl and Cu were also measured with respect to the 1381 keV gamma-line of 49Ti. Different samples like NH4Cl, Ti metal, cobalt chloride and other stoichiometric compounds and pure metals were used for this purpose. Prompt gamma-rays were accumulated using a 22% HPGe detector connected to a PC based 8k MCA in single mode counting. The energy calibration in the range of 100–8500 keV was carried out using gamma-rays from 152Eu and 60Co, and the prompt gamma-rays from 36Cl whereas the absolute detection efficiency for this energy range was determined using 152Eu and prompt gamma-rays from 36Cl and 49Ti.
引用
收藏
页码:303 / 307
页数:4
相关论文
共 50 条
  • [21] Produced water characterization by prompt gamma-ray neutron activation analysis
    Meric, Ilker
    Johansen, Geir A.
    Holstad, Marie B.
    Wang, Jiaxin
    Gardner, Robin P.
    [J]. MEASUREMENT SCIENCE AND TECHNOLOGY, 2011, 22 (12)
  • [22] PROMPT GAMMA-RAY NEUTRON-ACTIVATION ANALYSIS OF RIVER SEDIMENTS
    SPYCHALA, M
    MICHAELIS, W
    FANGER, HU
    [J]. NUCLEAR GEOPHYSICS, 1987, 1 (04): : 309 - 317
  • [23] Imaging of heterogeneous materials by prompt gamma-ray neutron activation analysis
    Staples, P
    Prettyman, T
    Lestone, J
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 906 - 908
  • [24] k0 Standardization approach in neutron-induced prompt gamma-ray analysis at JAERI
    Matsue, H
    Yonezawa, C
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2000, 245 (01) : 189 - 194
  • [25] k0 Standardization Approach in Neutron-Induced Prompt Gamma-Ray Analysis at JAERI
    H. Matsue
    C. Yonezawa
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2000, 245 : 189 - 194
  • [26] Application of the k0 method in neutron activation analysis and in prompt gamma activation analysis
    Revay, Zs
    Kennedy, G.
    [J]. RADIOCHIMICA ACTA, 2012, 100 (8-9) : 687 - 698
  • [27] Analytical capability of an explosives detection by a prompt gamma-ray neutron activation analysis
    Im, Hee-Jung
    Cho, Hyun-Je
    Song, Byoung Chul
    Park, Yong Joon
    Chung, Yong-Sam
    Kim, Won-Ho
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2006, 566 (02): : 442 - 447
  • [28] Cold neutron prompt gamma-ray activation analysis at NIST — Recent developments
    R. L. Paul
    R. M. Lindstrom
    A. E. Heald
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 1997, 215 : 63 - 68
  • [29] Cold neutron prompt gamma-ray activation analysis at NIST - Recent developments
    Paul, RL
    Lindstrom, RM
    Heald, AE
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 1997, 215 (01) : 63 - 68
  • [30] Determination of boron in materials by cold neutron prompt gamma-ray activation analysis
    Paul, RL
    [J]. ANALYST, 2005, 130 (01) : 99 - 103