Dual-tracer fluorescence thermometry measurements in a heated channel

被引:0
|
作者
Myeongsub Kim
Minami Yoda
机构
[1] Georgia Institute of Technology,George W. Woodruff School of Mechanical Engineering
来源
Experiments in Fluids | 2010年 / 49卷
关键词
PDMS; Poiseuille Flow; Heat Transfer Correlation; Cartridge Heater; Microchannel Heat Sink;
D O I
暂无
中图分类号
学科分类号
摘要
The exponential growth of component density in microelectronics has renewed interest in compact and high heat flux thermal management technologies that can handle local heat fluxes exceeding 1 kW/cm2. Accurate and spatially resolved thermometry techniques that can measure liquid-phase temperatures without disturbing the coolant flow are important in developing new heat exchangers employing forced-liquid and evaporative cooling. This paper describes water temperature measurements using dual-tracer fluorescence thermometry (DFT) with fluorescein and sulforhodamine B in laminar Poiseuille flow through polydimethyl siloxane-glass channels heated on one side. The major advantage of using the ratio of the signals from these two fluorophores is their temperature sensitivity of 4.0–12% per °C—a significant improvement over previous DFT studies at these spatial resolutions. For an in-plane spatial resolution of 30 μm, the average experimental uncertainties in the temperature data are estimated to be 0.3°C.
引用
收藏
页码:257 / 266
页数:9
相关论文
共 50 条
  • [21] Dual-tracer PET studies without arterial sampling
    Koeppe, R
    Joshi, A
    Frey, K
    Snyder, S
    Kilbourn, M
    Fessler, J
    NEUROIMAGE, 2004, 22 : T115 - T116
  • [22] DYNAMIC OR EARLY IMAGING IN DUAL-TRACER PARATHYROID SCINTIGRAPHY
    GREENBERG, SB
    PARK, CH
    INTENZO, C
    CLINICAL NUCLEAR MEDICINE, 1986, 11 (09) : 627 - 628
  • [23] Dual-Tracer PET/CT in HCC Staging and Management
    不详
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59 (05) : 15N - 15N
  • [24] DUAL-TRACER TECHNIQUE - AN EXPANSION OF CLINICAL VALUE OF SCANNING
    GOODRICH, JK
    WILKINSO.R
    HARRIS, CC
    CARRANZA, J
    WYRICK, AJ
    AMERICAN JOURNAL OF ROENTGENOLOGY RADIUM THERAPY AND NUCLEAR MEDICINE, 1967, 101 (04): : 1005 - &
  • [25] Neuroinflammation in Murine Endotoxemia: A Dual-Tracer MicroPET Evaluation
    Palandira, Santhoshi Poonacha
    Zeng, Qiong
    Turecki, Lauren
    Addorisio, Meghan
    Tsaava, Tea
    Chang, Eric
    Yilong, Ma
    Carrion, Joseph
    Tracey, Kevin
    Pavlov, Valentin
    FASEB JOURNAL, 2021, 35
  • [26] Signal separation of simultaneous dual-tracer PET imaging based on global spatial information and channel attention
    Fang, Jingwan
    Zeng, Fuzhen
    Liu, Huafeng
    EJNMMI PHYSICS, 2024, 11 (01):
  • [27] A CONTINUOUS FAST-RESPONSE DUAL-TRACER ANALYZER FOR HALOGENATED ATMOSPHERIC TRACER STUDIES
    RYDOCK, JP
    LAMB, BK
    JOURNAL OF ATMOSPHERIC AND OCEANIC TECHNOLOGY, 1994, 11 (05) : 1262 - 1272
  • [28] Joint Direct Dynamic Analysis in Dual-Tracer PET Imaging
    Zhu, Wentao
    Feng, Tao
    Chen, Mu
    Dong, Yun
    Bao, Jun
    Li, Hongdi
    2016 IEEE NUCLEAR SCIENCE SYMPOSIUM, MEDICAL IMAGING CONFERENCE AND ROOM-TEMPERATURE SEMICONDUCTOR DETECTOR WORKSHOP (NSS/MIC/RTSD), 2016,
  • [29] Dual-Tracer Parathyroid Imaging Using Joint SPECT Reconstruction
    Jaruwan Onwanna
    Maythinee Chantadisai
    Tawatchai Chaiwatanarat
    Yothin Rakvongthai
    Nuclear Medicine and Molecular Imaging, 2023, 57 : 126 - 136
  • [30] Dual-tracer background subtraction approach for fluorescent molecular tomography
    Tichauer, Kenneth M.
    Holt, Robert W.
    El-Ghussein, Fadi
    Davis, Scott C.
    Samkoe, Kimberley S.
    Gunn, Jason R.
    Leblond, Frederic
    Pogue, Brian W.
    JOURNAL OF BIOMEDICAL OPTICS, 2013, 18 (01)