Feasibility of simultaneous dual-isotope myocardial perfusion acquisition using a lower dose of sestamibi

被引:0
|
作者
Kwok C.G. [1 ]
Wu S. [1 ]
Tsang H.P. [1 ]
Strauss H.W. [1 ,2 ]
机构
[1] Division of Nuclear Medicine, Department of Radiology, Stanford Univ. School of Medicine, Stanford, CA
[2] Division of Nuclear Medicine, Department of Radiology, Stanford Univ. School of Medicine, Stanford, CA 94305-5281
关键词
Dual isotope; Myocardial perfusion; Simultaneous acquisition; Technetium-99m sestamibi; Thallium-201;
D O I
10.1007/BF01728764
中图分类号
学科分类号
摘要
The feasibility of simultaneous dual-isotope myocardial perfusion imaging was assessed using a ca. 12 mCi dose of technetium-99m sestamibi (MIBI) and ca. 3 mCi thallium-201. Planar and single-photon emission tomographic (SPET) data from 40 patients (41 studies) imaged with both a single- and a dual-isotope protocol were analyzed. Rest injected 201Tl (pure-Tl) images were acquired using 20% windows at 70 and 166 keV about 15 min after the 201Tl injection. Patients were then stressed, and at peak stress 99mTc-sestamibi was injected. About 30 min later 99mTc data were recorded with a 20% window center at 140 keV, and simultaneous 201Tl (dual-Tl) data were recorded with a single 20% window centered at 80 keV. Total myocardial counts based on SPET data in the dual-Tl images were increased by 18.61% ± 2.91% (SEM) (range: -12.8% to 84.1%) compared to pure-Tl images. Region of interest analysis revealed the greater increase in counts in the apical region and the least in the lateral wall. Pure Tl and dual-Tl images were visually evaluated for image quality (IQ) on a five-point scale (0 = unacceptable to 4 = excellent). Dual-Tl IQ was lower than that of pure-Tl in 61% of cases, and similar in 37% (12% of the pure-Tl and 41% of the dual-Tl images fell into the 0 and 1 categories). Thallium perfusion abnormalities were of similar extent in 70% of segments, less severe in 18%, and more severe in 12%. There was an inverse correlation with patient weight, such that patients weighing more than 180 lbs had substantially worse images than those below this cutoff value. While dual-tracer images are of lower quality, they are interpretable if the patient is not severely overweight.
引用
收藏
页码:281 / 285
页数:4
相关论文
共 50 条
  • [31] Optimization of acquisition parameters for simultaneous 201Tl and 99mTc dual-isotope myocardial imaging
    Wang, WT
    Tsui, BMW
    Lalush, DS
    Tocharoenchai, C
    Frey, EC
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2005, 52 (05) : 1227 - 1235
  • [32] A preliminary feasibility study of simultaneous dual-isotope imaging with a solid-state dedicated cardiac camera for evaluating myocardial perfusion and fatty acid metabolism
    Ko, Toshiyuki
    Utanohara, Yuko
    Suzuki, Yasuhiro
    Kurihara, Makiko
    Iguchi, Nobuo
    Umemura, Jun
    Sumiyoshi, Tetsuya
    Tomoike, Hitonobu
    HEART AND VESSELS, 2016, 31 (01) : 38 - 45
  • [33] Clinical Feasibility of Simultaneous Acquisition Rest 99mTc/Stress 201Tl Dual-Isotope Myocardial Perfusion Single-Photon Emission Computed Tomography With Semiconductor Camera
    Makita, Ayano
    Matsumoto, Naoya
    Suzuki, Yasuyuki
    Hori, Yusuke
    Kuronuma, Keiichiro
    Yoda, Shunichi
    Kasama, Shu
    Iguchi, Nobuo
    Suzuki, Yasuhiro
    Hirayama, Atsushi
    CIRCULATION JOURNAL, 2016, 80 (03) : 689 - 695
  • [34] A novel quantitative dual-isotope method for simultaneous ventilation and perfusion lung SPET
    Sánchez-Crespo, A
    Petersson, J
    Nyren, S
    Mure, M
    Glenny, RW
    Thorell, JO
    Jacobsson, H
    Lindahl, SGE
    Larsson, SA
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2002, 29 (07) : 863 - 875
  • [35] A novel quantitative dual-isotope method for simultaneous ventilation and perfusion lung SPET
    Alejandro Sánchez-Crespo
    Johan Petersson
    Sven Nyren
    Margareta Mure
    Robb W. Glenny
    Jan-Olov Thorell
    Hans Jacobsson
    Sten G. Lindahl
    Stig A. Larsson
    European Journal of Nuclear Medicine and Molecular Imaging, 2002, 29 : 863 - 875
  • [36] A preliminary feasibility study of simultaneous dual-isotope imaging with a solid-state dedicated cardiac camera for evaluating myocardial perfusion and fatty acid metabolism
    Toshiyuki Ko
    Yuko Utanohara
    Yasuhiro Suzuki
    Makiko Kurihara
    Nobuo Iguchi
    Jun Umemura
    Tetsuya Sumiyoshi
    Hitonobu Tomoike
    Heart and Vessels, 2016, 31 : 38 - 45
  • [37] A NEW THALLIUM-TECHNETIUM DUAL-ISOTOPE G-SPECT TECHNIQUE FOR SIMULTANEOUS MYOCARDIAL PERFUSION AND MOTION ANALYSIS
    CONSTANTINESCO, A
    MERTZ, L
    BRUNOT, B
    RAVIER, S
    CHOQUET, P
    MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 1995, 19 (04): : 190 - 198
  • [38] QUANTITATIVE ASSESSMENT OF REVERSIBILITY FOR REST TI-201 STRESS TC-99M SESTAMIBI SEPARATE ACQUISITION DUAL-ISOTOPE MYOCARDIAL PERFUSION SPECT - DEVELOPMENT AND PROSPECTIVE VALIDATION
    AREEDA, J
    VANTRAIN, K
    KIAT, H
    FRIEDMAN, J
    GERMANO, G
    SILAGAN, G
    GARCIA, E
    BERMAN, D
    JOURNAL OF NUCLEAR MEDICINE, 1993, 34 (05) : P64 - P64
  • [39] MYOCARDIAL PERFUSION MEASURED BY DUAL-ISOTOPE ACQUISITION OF (81)RUBIDIUM (81M)KRYPTON - AN EXPERIMENTAL-VERIFICATION OF THE METHOD
    STOLL, HP
    BAY, W
    VOGEL, W
    OZBEK, C
    HANSER, A
    SCHIEFFER, H
    HARBAUER, G
    BASIC RESEARCH IN CARDIOLOGY, 1994, 89 (04) : 354 - 365
  • [40] Feasibility of myocardial dual-isotope perfusion imaging combined with gated single photon emission tomography for assessing coronary artery disease
    Fukuoka, S
    Maeno, M
    Nakagawa, S
    Fukunaga, T
    Yamada, H
    Eto, T
    NUCLEAR MEDICINE COMMUNICATIONS, 2002, 23 (01) : 19 - 29