Multislice CT in imaging the liver

被引:0
|
作者
Paul M. Silverman
机构
[1] MD Anderson Cancer Center,Department of Radiology
[2] Division of Diagnostic Imaging,undefined
关键词
Liver; metastases; contrast; multislice; multidetector CT;
D O I
10.1102/1470-7330.2003.0016
中图分类号
学科分类号
摘要
The objective of this paper is to address the dramatic impact of multislice CT (MSCT) in imaging the liver. Standard helical (spiral) CT has finally allowed for scanning the majority of the liver during the critical portal venous phase (PVP). This is often referred to as the ‘optimal temporal window’. In general, it occurs following a 70 s scan delay and is coincidental with the maximal delivery of contrast via the portal vein that provides 80% of the hepatic blood supply. This yields maximal conspicuity between low-attenuation lesions and the dramatically enhanced normal liver parenchyma at routine injection rates of 2–3 ml/s. Most importantly, these scanners, when compared to single-slice scanners, avoid impinging on the ‘equilibrium’ phase where tumors can become isodense/invisible. The introduction of MSCT with four, eight and 16-detector systems has significantly increased imaging speed. Volumetric CT will continue to increase speed in the future. This provides a number of important gains that will be described.
引用
收藏
页码:149 / 154
页数:5
相关论文
共 50 条
  • [21] Multislice CT angiography: a practical guide to CT angiography in vascular imaging and intervention
    Duddalwar, VA
    BRITISH JOURNAL OF RADIOLOGY, 2004, 77 : S27 - S38
  • [22] Impact of slice thickness on the detection of liver lesions with multislice CT
    Basilico, R
    Filippone, A
    Ricciardi, M
    Iezzi, A
    Bonomo, L
    RADIOLOGY, 2000, 217 : 368 - 368
  • [23] Multislice spiral CT angiography in evaluation of liver transplantation candidates
    Dong-Mei Guo and Jie Bian Dalian
    Hepatobiliary & Pancreatic Diseases International, 2005, (01) : 32 - 36
  • [24] Multislice CT
    Baque, Pia-Elisabeth
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2021, 193 (02): : 215 - 217
  • [25] Detection and characterization of benign focal liver lesions with multislice CT
    J. T. Winterer
    E. Kotter
    N. Ghanem
    M. Langer
    European Radiology, 2006, 16 : 2427 - 2443
  • [26] Multislice CT
    Morcos, SK
    Weir, J
    BRITISH JOURNAL OF RADIOLOGY, 2004, 77 : S1 - S1
  • [27] Assessment of Hemodynamics in a Rat Model of Liver Cirrhosis with Precancerous Lesions Using Multislice Spiral CT Perfusion Imaging
    Ma, Guolin
    Bai, Rongjie
    Jiang, Huijie
    Hao, Xuejia
    Ling, Zaisheng
    Li, Kefeng
    BIOMED RESEARCH INTERNATIONAL, 2013, 2013
  • [28] Comparative imaging quality and artifact of monoslice and multislice helical CT
    Foley, WD
    Milwaukee, WI
    Wheeler, MM
    Jacobson, DR
    Jenkins, C
    Hohenwalter, MD
    Quiroz, FA
    RADIOLOGY, 1999, 213P : 317 - 317
  • [29] Multiplanar functional imaging of the larynx and hypopharynx with multislice spiral CT
    Lell, MM
    Greess, H
    Hothorn, T
    Janka, R
    Bautz, WA
    Baum, U
    EUROPEAN RADIOLOGY, 2004, 14 (12) : 2198 - 2205
  • [30] Multiplanar functional imaging of the larynx and hypopharynx with multislice spiral CT
    Michael M. Lell
    Holger Greess
    Torsten Hothorn
    Rolf Janka
    Werner A. Bautz
    Ulrich Baum
    European Radiology, 2004, 14 : 2198 - 2205