Flow fields with vortex in a small semi-open axial fan

被引:0
|
作者
Norimasa. Shiomi
Yoichi Kinoue
Ying zi Jin
Toshiaki Setoguchi
Kenji Kaneko
机构
[1] Saga University,Department of Mechanical Engineering
[2] Zhejiang Sci-Tech University,Institute of Mechatronics
[3] Xiasha Higher Educational Zone,undefined
来源
关键词
fan; semi-open type; vortex; tip clearance;
D O I
暂无
中图分类号
学科分类号
摘要
In order to clarify the effect of tip clearance (TC) size on fan performance and the flow field at rotor outlet in a small semi-open axial fan, the experimental investigation was carried out. The tip diameter of test fan rotor was 180mm and test TC sizes were 1mm (TC=1mm) and 4mm (TC=4mm). Fan characteristics tests were carried out for two cases of TC size and three-dimensional velocity fields at rotor outlet were measured using a single slant hot-wire probe at four flow-rate conditions. As a result, it was found that the pressure — flow-rate characteristics curves for two cases showed almost the same tendency. However, the ensemble averaged velocity profiles along radial measurement stations of TC=4mm largely changed compared with that of TC=1mm in cases of small flow-rate condition. From the phase-locked averaging results, it was also found that the vortex existed in the rotor outlet flow field of high flow-rate condition for each TC case. Compared with the vortices for TC=1mm and TC=4mm, the vortex for TC=4mm was stronger than that for TC=1mm.
引用
收藏
页码:294 / 300
页数:6
相关论文
共 50 条
  • [21] Conventional and semi-open kyphoplasty
    Boszczyk, BM
    Bierschneider, M
    Hauck, S
    Vastmans, J
    Potulski, M
    Beisse, R
    Robert, B
    Jaksche, H
    ORTHOPADE, 2004, 33 (01): : 13 - 21
  • [22] Flow patterns in a semi-open centrifugal blood pump with flow visualization analysis
    Asztalos, B
    Yamane, T
    Nishida, M
    Taenaka, Y
    Masuzawa, T
    Endo, S
    Tsukiya, T
    Konishi, Y
    Miyazoe, Y
    Ito, K
    PROCEEDINGS OF THE 20TH ANNUAL INTERNATIONAL CONFERENCE OF THE IEEE ENGINEERING IN MEDICINE AND BIOLOGY SOCIETY, VOL 20, PTS 1-6: BIOMEDICAL ENGINEERING TOWARDS THE YEAR 2000 AND BEYOND, 1998, 20 : 447 - 449
  • [23] SEMI-OPEN ANECHOIC CHAMBER
    KOOB, KA
    LIESENKOTTER, BHC
    MICROWAVE JOURNAL, 1978, 21 (06) : 120 - 123
  • [24] Semi-open ANC Headphone
    Roschmann-Foudhaili, Hatem
    2016 AES INTERNATIONAL CONFERENCE ON HEADPHONE TECHNOLOGY, 2016,
  • [25] SEMI-OPEN SET STRUCTURE
    CROSSLEY, SG
    ANNALES DE LA SOCIETE SCIENTIFIQUE DE BRUXELLES SERIES 1-SCIENCES MATHEMATIQUES ASTRONOMIQUES ET PHYSIQUES, 1979, 93 (03): : 166 - 174
  • [26] Aerodynamic noise prediction of the open axial flow fan
    Wang, Jia-Bing
    Liu, Min
    Wu, Ke-Qi
    2007, Science Press, 18,Shuangqing Street,Haidian, Beijing, 100085, China (28):
  • [27] Exchange rate changes and export prices in a small semi-open economy
    Ogun, O
    OPEN ECONOMIES REVIEW, 2000, 11 (02) : 127 - 134
  • [28] Study on flow fields and losses of the stationary components in an axial flow fan
    Liang, Yaxun
    Li, Jingyin
    Tian, Hua
    Hsi-An Chiao Tung Ta Hsueh/Journal of Xi'an Jiaotong University, 2008, 42 (03): : 269 - 272
  • [29] Exchange Rate Changes and Export Prices in a Small Semi-Open Economy
    Oluremi Ogun
    Open Economies Review, 2000, 11 : 127 - 134
  • [30] Effect of blade top clearance on semi-open fuel pump performance and leakage vortex
    Liu Xin
    Li Yibin
    Wang Bo
    Zhang Shengfu
    Jing Weimin
    Li Wanqi
    Journal of the Brazilian Society of Mechanical Sciences and Engineering, 2023, 45