Newtonian (moving mass) calibration of tilt and gravity meters and the investigation of some factors influencing its accuracy

被引:0
|
作者
Gábor Papp
Dániel István Csáki
Judit Benedek
机构
[1] Institute of Earth Physics and Space Science,
来源
Journal of Geodesy | 2022年 / 96卷
关键词
Moving mass calibration; Newtonian gravitational attraction; Tilt meters; Nanoradian resolution; Gravity meters; Prisms; Polyhedrons;
D O I
暂无
中图分类号
学科分类号
摘要
The idea of moving mass calibration (MMC) of relative gravity meters dates back to the seventies of the last century. Probably the MMC apparatus built in the underground Mátyáshegy Gravity and Geodynamics Laboratory Budapest has been used most extensively and several spring type instruments (LaCoste and Romberg and Scintrex) have been investigated and calibrated by it. Its test mass is a cylindrical ring having a weight of 3 tons. Its main advantage is simplicity in terms of metrology. The same principle and technology can be used to test compact tilt sensors having nanoradian resolution capability. Up to now rigorous testing methods below microradian range were not available in practice. The analysis of the so-called off-axis variation of the gravitational vector generated by the vertical movement of the cylindrical ring mass of the Mátyáshegy MMC device, however, showed that a sufficiently accurate reference signal having (15 ± 0.02) nrad peak-to-peak amplitude can be provided for calibration. It is just in the range of tilt induced by earth tide effect, which is a “standard” signal component in the time series recorded in observatory environment. In the first part of the paper, a discussion of the proposed methodology of tilt meter calibration is given. Then the analysis of the effect of volumetric discretization of the cylindrical ring on the accuracy of calibration is provided. Finally, possible material inhomogeneities of the ring mass and their gravitational effects are investigated by forward simulations and inversion. For this purpose the results of 300 gravimeter calibration experiments, analysed and published earlier, were utilized.
引用
收藏
相关论文
共 2 条
  • [1] Newtonian (moving mass) calibration of tilt and gravity meters and the investigation of some factors influencing its accuracy
    Papp, Gabor
    Csaki, Daniel Istvan
    Benedek, Judit
    [J]. JOURNAL OF GEODESY, 2022, 96 (12)
  • [2] Investigation of Factors Influencing Calibration Accuracy of Camera
    Wang, Jianhua
    Wu, Yuping
    Yang, Zhao
    [J]. ADVANCES IN MANUFACTURING SCIENCE AND ENGINEERING, PTS 1-4, 2013, 712-715 : 2331 - 2335