Biomechanical changes in the proximal femur before and after removal of femoral neck system

被引:0
|
作者
Nan, Chong [1 ]
Liu, Yuxiu [1 ]
Zhang, Di [2 ]
Qin, Yazhuo [1 ]
Yu, Hetong [1 ]
Ma, Zhanbei [1 ]
机构
[1] Baoding 1 Cent Hosp, Dept Orthoped, Baoding 071000, Hebei, Peoples R China
[2] Hebei Med Univ, Hosp 3, Dept Spinal Surg, Shijiazhuang 050000, Hebei, Peoples R China
来源
关键词
Femoral neck system; Cannulated screw removal; Biomechanical effect; Finite element analysis; FINITE-ELEMENT-ANALYSIS; FRACTURE;
D O I
10.1186/s13018-024-04769-x
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background As an innovative internal fixation system, FNS (femoral neck system) is increasingly being utilized by surgeons for the treatment of femoral neck fractures. At present, there have been numerous finite element analysis experiments studying the immediate stability of FNS and CSS in treating femoral neck fractures. However, there is scarce mechanical analysis available regarding the effects post internal fixation removal. This study aimed to investigate the alterations in mechanical parameters of the proximal femur before and after the removal of FNS (femoral neck system), and to assess potential distinctions in indicators following the extraction of CSS (Cannulated Screws).Methods A proximal femur model was reconstructed using finite element numerical techniques. The models for CSS and FNS were formulated utilizing characteristics and parametric definitions. The internal fixation was combined with a normal proximal femur model to simulate the healing state after fracture surgery. Within the framework of static analysis, consistent stress burdens were applied across the entirety of the models. The total deformation and equivalent stress of the proximal femur were recorded before and after the removal of internal fixation.Results Under the standing condition, the total deformation of the model before and after removing CSS was 0.99 mm and 1.10 mm, respectively, indicating an increase of 12%. The total deformation of the model before and after removing FNS was 0.65 mm and 0.76 mm, respectively, indicating an increase of 17%. The equivalent stress for CSS and FNS were 55.21 MPa and 250.67 MPa, respectively. The average equivalent stress on the cross-section of the femoral neck before and after removal of CSS was 7.76 MPa and 6.11 MPa, respectively. The average equivalent stress on the cross-section of the femoral neck before and after removal of FNS was 9.89 MPa and 8.79 MPa, respectively.Conclusions The retention of internal fixation may contribute to improved stability of the proximal femur. However, there still existed risks of stress concentration in internal fixation and stress shielding in the proximal femur. Compared to CSS, the removal of FNS results in larger bone tunnels and insufficient model stability. Further clinical interventions are recommended to address this issue.
引用
收藏
页数:8
相关论文
共 50 条
  • [41] Changes in Bone Mineral Density and Femoral Neck Narrowing in the Proximal Femur Three to Five Years After Hip Resurfacing Versus Conventional Total Hip Arthroplasty
    Gerhardt, Davey M. J. M.
    Smolders, Jose M. H.
    Rijnders, Ton A. J. M.
    Hol, Annemiek
    van Susante, Job L. C.
    JOURNAL OF ARTHROPLASTY, 2015, 30 (02): : 308 - 314
  • [42] Delirium before and after operation for femoral neck fracture
    Edlund, A
    Lundström, M
    Brännström, B
    Bucht, G
    Gustafson, Y
    JOURNAL OF THE AMERICAN GERIATRICS SOCIETY, 2001, 49 (10) : 1335 - 1340
  • [43] Prophylactic Femoral Neck Fixation in an Osteoporosis Femur Model: A Novel Surgical Technique with Biomechanical Study
    Park, Kyeong-Hyeon
    Oh, Chang-Wug
    Kim, Joon-Woo
    Kim, Hee-Jun
    Kim, Dong-Hyun
    Lee, Jin-Han
    Hong, Won-Ki
    Oh, Jong-Keon
    JOURNAL OF CLINICAL MEDICINE, 2023, 12 (01)
  • [44] FE-simulation of the proximal femur before and after hip arthroplasty
    Onisoru, J.
    Iarovici, A.
    Capitanu, L.
    Popescu, M.
    JOURNAL OF THE BALKAN TRIBOLOGICAL ASSOCIATION, 2007, 13 (01): : 103 - 112
  • [45] The Fixion proximal femur nailing system: biomechanical properties of the nail and a cadaveric study
    Steinberg, EL
    Blumberg, N
    Dekel, S
    JOURNAL OF BIOMECHANICS, 2005, 38 (01) : 63 - 68
  • [46] Cortical and trabecular bone in the femoral neck both contribute to proximal femur failure load prediction
    Manske, S. L.
    Liu-Ambrose, T.
    Cooper, D. M. L.
    Kontulainen, S.
    Guy, P.
    Forster, B. B.
    McKay, H. A.
    OSTEOPOROSIS INTERNATIONAL, 2009, 20 (03) : 445 - 453
  • [47] Computed tomographic evaluation of the proximal femur: A predictive classification in displaced femoral neck fracture management
    Magu, Narender Kumar
    Magu, Sarita
    Rohilla, Rajesh Kumar
    Batra, Amit
    Jaipuria, Abhishek
    Singh, Amanpreet
    INDIAN JOURNAL OF ORTHOPAEDICS, 2014, 48 (05) : 476 - 483
  • [48] Cortical and trabecular bone in the femoral neck both contribute to proximal femur failure load prediction
    S. L. Manske
    T. Liu-Ambrose
    D. M. L. Cooper
    S. Kontulainen
    P. Guy
    B. B. Forster
    H. A. McKay
    Osteoporosis International, 2009, 20 : 445 - 453
  • [49] Computed tomographic evaluation of the proximal femur: A predictive classifcation in displaced femoral neck fracture management
    Narender Kumar Magu
    Sarita Magu
    Rajesh Kumar Rohilla
    Amit Batra
    Abhishek Jaipuria
    Amanpreet Singh
    Indian Journal of Orthopaedics, 2014, 48 : 476 - 483
  • [50] Differences in proximal femur geometry distinguish vertebral from femoral neck fractures in osteoporotic women
    Gnudi, S
    Malavolta, N
    Testi, D
    Viceconti, M
    BRITISH JOURNAL OF RADIOLOGY, 2004, 77 (915): : 219 - 223