Prognostic value of indocyanine green-plasma disappearance rate in critically ill patients

被引:0
|
作者
SG Sakka
A Meier-Hellmann
K Reinhart
机构
[1] Friedrich-Schiller-University,Department of Anesthesiology and Intensive Care Medicine
来源
Critical Care | / 6卷 / Suppl 1期
关键词
Public Health; Blood Flow; Liver Function; Emergency Medicine; Prognostic Marker;
D O I
10.1186/cc1664
中图分类号
学科分类号
摘要
引用
收藏
相关论文
共 50 条
  • [1] Prognostic value of the indocyanine green plasma disappearance rate in critically ill patients
    Sakka, SG
    Reinhart, K
    Meier-Hellman, A
    [J]. CHEST, 2002, 122 (05) : 1715 - 1720
  • [2] Prognostic value of indocyanine green: Plasma disappearance rate in critically ill patients
    Sakka, SG
    Boegel, D
    Meier-Hellmann, A
    Reinhart, K
    [J]. INTENSIVE CARE MEDICINE, 2001, 27 : S231 - S231
  • [3] Prognostic value of indocyanine green plasma disappearance rate in critically ill patients
    Sakka, SG
    Klein, M
    Bögel, D
    Meier-Hellmann, A
    Reinhart, K
    [J]. CRITICAL CARE MEDICINE, 2001, 29 (12) : A94 - A94
  • [4] Indocyanine green plasma disappearance rate as dynamic liver function test in critically ill patients
    Halle, B. M.
    Poulsen, T. D.
    Pedersen, H. P.
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2014, 58 (10) : 1214 - 1219
  • [5] Relation between indocyanine green (ICG) plasma disappearance rate and ICG blood clearance in critically ill patients
    Sakka, SG
    van Hout, N
    [J]. INTENSIVE CARE MEDICINE, 2006, 32 (05) : 766 - 769
  • [6] Relation between indocyanine green (ICG) plasma disappearance rate and ICG blood clearance in critically ill patients
    Samir G. Sakka
    Nicole van Hout
    [J]. Intensive Care Medicine, 2006, 32 : 766 - 769
  • [7] Does indocyanine green accurately measure plasma volume independently of its disappearance rate from plasma in critically ill patients?
    Ishihara, H
    Iwakawa, T
    Hasegawa, T
    Muraoka, M
    Tsubo, T
    Matsuki, A
    [J]. INTENSIVE CARE MEDICINE, 1999, 25 (11) : 1252 - 1258
  • [8] Does indocyanine green accurately measure plasma volume independently of its disappearance rate from plasma in critically ill patients?
    H. Ishihara
    T. Iwakawa
    T. Hasegawa
    M. Muraoka
    T. Tsubo
    A. Matsuki
    [J]. Intensive Care Medicine, 1999, 25 : 1252 - 1258
  • [9] Comparison between invasive and non-invasive measurement of indocyanine-green plasma disappearance rate in critically ill patients
    Sakka, SG
    Meier-Hellmann, A
    Reinhart, K
    [J]. ANESTHESIOLOGY, 2000, 93 (3A) : U155 - U155
  • [10] Comparison of invasive and noninvasive measurements of indocyanine green plasma disappearance rate in critically ill patients with mechanical ventilation and stable hemodynamics
    Sakka, SG
    Reinhart, K
    Meier-Hellmann, A
    [J]. INTENSIVE CARE MEDICINE, 2000, 26 (10) : 1553 - 1556