Does indocyanine green accurately measure plasma volume independently of its disappearance rate from plasma in critically ill patients?

被引:0
|
作者
H. Ishihara
T. Iwakawa
T. Hasegawa
M. Muraoka
T. Tsubo
A. Matsuki
机构
[1] Department of Anesthesiology,
[2] University of Hirosaki School of Medicine,undefined
[3] Hirosaki-Shi,undefined
[4] 036–8562,undefined
[5] Japan e-mail: ishihara@cc.hirosaki-u.ac.jp Tel. + 81(1 72)39-5111 Fax + 81(1 72)39-51 12,undefined
来源
Intensive Care Medicine | 1999年 / 25卷
关键词
Key words Measurement technique; Plasma volume; Indocyanine green; Glucose; Hepatic function;
D O I
暂无
中图分类号
学科分类号
摘要
Objective: To determine whether plasma volume determined by the indocyanine green (ICG) dilution method (PV-ICG) is equally accurate independently of its disappearance rate from plasma in the critically ill.¶Design: Retrospective clinical investigation.¶Setting: Intensive care unit of a university teaching hospital.¶Patients and methods: 192 adult patients were initially enrolled. The PV-ICG and the initial distribution volume of glucose (IDVG) were calculated utilizing a one-compartment model by simultaneous administration of ICG 25 mg and glucose 5 g on the first day of measurement in each patient. Twenty-one patients were excluded from the study because of a higher PV-ICG/IDVG ratio ( > 0.45) indicating apparent overestimation of the PV-ICG associated with the generalized protein capillary leakage. The remaining 171 patients were divided into four groups according to the magnitude of their disappearance rate of ICG from plasma (Ke-ICG).¶Results: Convergence was assumed consistently in each ICG or glucose decay curve, even in the lower Ke-ICG less than 0.10/min. The relationship between the two volumes was not statistically different among groups.¶Conclusions: The results suggest that the measurement of the PV-ICG can be equally accurate independently of its disappearance rate from plasma unless there is generalized protein capillary leakage.
引用
收藏
页码:1252 / 1258
页数:6
相关论文
共 50 条
  • [1] Does indocyanine green accurately measure plasma volume independently of its disappearance rate from plasma in critically ill patients?
    Ishihara, H
    Iwakawa, T
    Hasegawa, T
    Muraoka, M
    Tsubo, T
    Matsuki, A
    [J]. INTENSIVE CARE MEDICINE, 1999, 25 (11) : 1252 - 1258
  • [2] Prognostic value of the indocyanine green plasma disappearance rate in critically ill patients
    Sakka, SG
    Reinhart, K
    Meier-Hellman, A
    [J]. CHEST, 2002, 122 (05) : 1715 - 1720
  • [3] Prognostic value of indocyanine green: Plasma disappearance rate in critically ill patients
    Sakka, SG
    Boegel, D
    Meier-Hellmann, A
    Reinhart, K
    [J]. INTENSIVE CARE MEDICINE, 2001, 27 : S231 - S231
  • [4] Prognostic value of indocyanine green plasma disappearance rate in critically ill patients
    Sakka, SG
    Klein, M
    Bögel, D
    Meier-Hellmann, A
    Reinhart, K
    [J]. CRITICAL CARE MEDICINE, 2001, 29 (12) : A94 - A94
  • [5] Prognostic value of indocyanine green-plasma disappearance rate in critically ill patients
    SG Sakka
    A Meier-Hellmann
    K Reinhart
    [J]. Critical Care, 6 (Suppl 1):
  • [6] Indocyanine green plasma disappearance rate as dynamic liver function test in critically ill patients
    Halle, B. M.
    Poulsen, T. D.
    Pedersen, H. P.
    [J]. ACTA ANAESTHESIOLOGICA SCANDINAVICA, 2014, 58 (10) : 1214 - 1219
  • [7] Does indocyanine green accurately measure plasma volume early after cardiac surgery?
    Ishihara, H
    Okawa, H
    Iwakawa, T
    Umegaki, N
    Tsubo, T
    Matsuki, A
    [J]. ANESTHESIA AND ANALGESIA, 2002, 94 (04): : 781 - 786
  • [8] Relation between indocyanine green (ICG) plasma disappearance rate and ICG blood clearance in critically ill patients
    Sakka, SG
    van Hout, N
    [J]. INTENSIVE CARE MEDICINE, 2006, 32 (05) : 766 - 769
  • [9] Relation between indocyanine green (ICG) plasma disappearance rate and ICG blood clearance in critically ill patients
    Samir G. Sakka
    Nicole van Hout
    [J]. Intensive Care Medicine, 2006, 32 : 766 - 769
  • [10] Comparison between invasive and non-invasive measurement of indocyanine-green plasma disappearance rate in critically ill patients
    Sakka, SG
    Meier-Hellmann, A
    Reinhart, K
    [J]. ANESTHESIOLOGY, 2000, 93 (3A) : U155 - U155