Modernizing the heat load control system of a once-through boiler unit at a thermal power station using a dynamic corrector

被引:0
|
作者
Yu. M. Kovrigo
M. A. Konovalov
A. S. Bunke
机构
[1] Kiev Polytechnic Institute National Technical University of the Ukraine,
关键词
Thermal Power Station; Amplitude Frequency Response; Dynamic Corrector; Boiler Unit; Loop Control System;
D O I
10.1134/S0040601512100072
中图分类号
学科分类号
摘要
Operation of the heat load control system of the once-through boiler of a 300-MW power unit in maneuverable modes of its operation is considered. A new functional structure of the algorithm for controlling inertial thermal power facilities is proposed. The controlled plant model is identified from experimental data, and the stability of the closed-loop control system is estimated in the working range of load is estimated. The results of simulation and tests carried out on Unit 2 at the Tripol’e thermal power station have shown that better quality of control processes in response to external and internal disturbances is achieved through the use of a dynamic corrector.
引用
收藏
页码:772 / 778
页数:6
相关论文
共 50 条
  • [41] A dynamic nonlinear model for a wide-load range operation of ultra-supercritical once-through boiler-turbine units
    Fan, He
    Su, Zhi-gang
    Wang, Pei-hong
    Lee, Kwang Y.
    ENERGY, 2021, 226
  • [42] Design of digital nuclear power small reactor once-through steam generator control system
    Qian, Hong
    Zou, Mingyao
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (07) : 2435 - 2443
  • [43] Using thermal test data to determine the minimum load of a 200-MW power unit with a PK-47 boiler at the Zainsk power station
    Belyakov I.I.
    Breus V.I.
    Barannikov A.B.
    Power Technology and Engineering, 2013, Springer Science and Business Media, LLC (47) : 133 - 138
  • [45] System Identification and Model-free Adaptive Control of Once-Through Steam Generator in Nuclear Power
    Tao, Mo
    Ke, Zhiwu
    Yu, Yagang
    2017 IEEE INTERNATIONAL CONFERENCE ON MECHATRONICS AND AUTOMATION (ICMA), 2017, : 1256 - 1261
  • [46] Dynamic simulation for analysis and optimization of the startup behavior of a heat-recovery steam generator with a once-through system
    Butterlin, A
    Fehn, T
    Lenk, U
    MODELLING AND SIMULATION OF STEAM GENERATORS AND FIRING SYSTEMS, 2000, 1534 : 45 - 55
  • [47] Dynamic simulation of a supercritical once-through heat recovery steam generator during load changes and start-up procedures
    Alobaid, Falah
    Stroehle, Jochen
    Epple, Bernd
    Kim, Hyun-Gee
    APPLIED ENERGY, 2009, 86 (7-8) : 1274 - 1282
  • [48] Flow Heat Transfer Characteristics and Dynamic Response of Once-Through Cooling Water System in Nuclear Power Plants Under Complex Operating Conditions
    Huang, Qian
    Zhi, Yifan
    Zhang, Rongyong
    Du, Xiaoze
    Zhang, Jingqi
    Wang, Jingyao
    ENERGIES, 2025, 18 (05)
  • [49] Robust & nonlinear control of an ultra-supercritical coal fired once-through boiler-turbine unit in order to optimize the uncertain problem
    Esmaeili, Mohammad
    Moradi, Hamed
    ENERGY, 2023, 282
  • [50] Coordinated Control of Once-through Boiler-turbine Units Using Feedforward-feedback Approach based on Stable Inversion
    Li, Lu
    Zeng, Deliang
    Chang, Taihua
    Lv, You
    2014 4TH AUSTRALIAN CONTROL CONFERENCE (AUCC), 2014, : 49 - 54