Modernizing the heat load control system of a once-through boiler unit at a thermal power station using a dynamic corrector

被引:0
|
作者
Yu. M. Kovrigo
M. A. Konovalov
A. S. Bunke
机构
[1] Kiev Polytechnic Institute National Technical University of the Ukraine,
关键词
Thermal Power Station; Amplitude Frequency Response; Dynamic Corrector; Boiler Unit; Loop Control System;
D O I
10.1134/S0040601512100072
中图分类号
学科分类号
摘要
Operation of the heat load control system of the once-through boiler of a 300-MW power unit in maneuverable modes of its operation is considered. A new functional structure of the algorithm for controlling inertial thermal power facilities is proposed. The controlled plant model is identified from experimental data, and the stability of the closed-loop control system is estimated in the working range of load is estimated. The results of simulation and tests carried out on Unit 2 at the Tripol’e thermal power station have shown that better quality of control processes in response to external and internal disturbances is achieved through the use of a dynamic corrector.
引用
收藏
页码:772 / 778
页数:6
相关论文
共 50 条
  • [1] MEASUREMENT OF THERMAL LOAD OF A ONCE-THROUGH BOILER
    RUSHCHIN.VM
    FRENKEL, AY
    KHVOSTOV.NY
    FRIDMAN, LI
    MARENKO, AF
    THERMAL ENGINEERING, 1968, 15 (09) : 67 - &
  • [2] EXTENDED LINEAR MATHEMATICAL MODEL FOR A POWER STATION UNIT WITH A ONCE-THROUGH BOILER.
    Borsi, Ladislaus
    1600, (03):
  • [3] Design and application of feed water control system for once-through boiler power generation unit
    Han, Zhong-Xu
    Pan, Gang
    Qiu, Zhong-Chang
    Ma, Huan-Jun
    Zhang, Wei
    Huang, Huan-Pao
    Feng, Jian
    Zhou, Chuan-Xin
    Zhongguo Dianji Gongcheng Xuebao/Proceedings of the Chinese Society of Electrical Engineering, 2010, 30 (02): : 7 - 16
  • [4] A dynamic nonlinear model for a once-through boiler-turbine unit in low load
    Niu, Yuguang
    Du, Ming
    Ge, Weichun
    Luo, Huanhuan
    Zhou, Guiping
    APPLIED THERMAL ENGINEERING, 2019, 161
  • [5] AN ANALYSIS OF THE DYNAMICS OF A MULTICONNECTED SYSTEM OF CONTROL OF POWER AND TEMPERATURE OF A POWER-GENERATING UNIT WITH A ONCE-THROUGH BOILER
    BILENKO, VA
    DAVYDOV, NI
    CHESNOKOVSKII, VZ
    ROSICH, NP
    THERMAL ENGINEERING, 1987, 34 (10) : 528 - 534
  • [6] Analysis and Control of Once-through Boiler-Turbine Unit
    Huang Weijian
    Wu Yuzhong
    Kan Weimin
    Zhang Xi
    ENERGY AND POWER TECHNOLOGY, PTS 1 AND 2, 2013, 805-806 : 678 - 681
  • [7] Cascade PID Control of Desuperheating Water System of Supercritical Power Generation Unit Once-through Boiler
    Du, Ronghua
    Zhang, Pengtao
    Wang, Hongbin
    Guo, Ruijun
    PROCEEDINGS OF THE 10TH WORLD CONGRESS ON INTELLIGENT CONTROL AND AUTOMATION (WCICA 2012), 2012, : 3369 - 3371
  • [8] ANALYTICAL INVESTIGATION OF DIFFERENT VERSIONS OF A POWER CONTROL-SYSTEM FOR A GENERATING UNIT WITH A ONCE-THROUGH BOILER
    DAVYDOV, NI
    KANTSYREVA, LN
    THERMAL ENGINEERING, 1971, 18 (04) : 94 - +
  • [9] Once-through Boiler Steam Temperature Control Using Dynamic Matrix Control Technique
    Kim, Woohun
    Moon, Un-Chul
    Lee, Kwang Y.
    Jung, Won-Hee
    Kim, Sung-Ho
    IEEE POWER AND ENERGY SOCIETY GENERAL MEETING 2010, 2010,
  • [10] Using the Localization Method for Once-through Boiler Control
    Suvorov, D. A.
    Frantsuzova, G. A.
    Zemtsov, N. S.
    2015 INTERNATIONAL SIBERIAN CONFERENCE ON CONTROL AND COMMUNICATIONS (SIBCON), 2015,