In vivo dosimetry using MOSkin detector during Cobalt-60 high-dose-rate (HDR) brachytherapy of skin cancer

被引:0
|
作者
Z. Jamalludin
W. L. Jong
G. F. Ho
A. B. Rosenfeld
N. M. Ung
机构
[1] University of Malaya Medical Centre,Medical Physics Unit
[2] University of Malaya Medical Centre,Department of Clinical Oncology
[3] University of Malaya,Clinical Oncology Unit, Faculty of Medicine
[4] University of Wollongong,Centre for Medical Radiation Physics
关键词
Mo; In vivo dosimetry; Skin dose; Co-60 HDR brachytherapy;
D O I
暂无
中图分类号
学科分类号
摘要
The MOSkin, a metal–oxide semiconductor field-effect transistor based detector, is suitable for evaluating skin dose due to its water equivalent depth (WED) of 0.07 mm. This study evaluates doses received by target area and unavoidable normal skin during a the case of skin brachytherapy. The MOSkin was evaluated for its feasibility as detector of choice for in vivo dosimetry during skin brachytherapy. A high-dose rate Cobalt-60 brachytherapy source was administered to the tumour located at the medial aspect of the right arm, complicated with huge lymphedema thus limiting the arm motion. The source was positioned in the middle of patients’ right arm with supine, hands down position. A 5 mm lead and 5 mm bolus were sandwiched between the medial aspect of the arm and lateral chest to reduce skin dose to the chest. Two calibrated MOSkin detectors were placed on the target and normal skin area for five treatment sessions for in vivo dose monitoring. The mean dose to the target area ranged between 19.9 and 21.1 Gy and was higher in comparison with the calculated dose due to contribution of backscattered dose from lead. The mean measured dose at normal skin chest area was 1.6 Gy (1.3–1.9 Gy), less than 2 Gy per fraction. Total dose in EQD2 received by chest skin was much lower than the recommended skin tolerance. The MOSkin detector presents a reliable real-time dose measurement. This study has confirmed the applicability of the MOSkin detector in monitoring skin dose during brachytherapy treatment due to its small sensitive volume and WED 0.07 mm.
引用
收藏
页码:1099 / 1107
页数:8
相关论文
共 50 条
  • [41] Characterization of microMOSFET detectors for in vivo dosimetry in high-dose-rate brachytherapy with 192Ir
    Ruiz-Arrebola, Samuel
    Fabregat-Borras, Rosa
    Rodriguez, Eduardo
    Fernandez-Montes, Manuel
    Perez-Macho, Mercedes
    Ferri, Maria
    Garcia, Ana
    Cardenal, Juan
    Pacheco, Maria T.
    Anchuelo, Javier
    Tornero-Lopez, Ana M.
    Prada, Pedro J.
    Guirado, Damian
    MEDICAL PHYSICS, 2020, 47 (05) : 2242 - 2253
  • [42] In vivo dosimetry of high-dose-rate brachytherapy:: Study on 61 head-and-neck cancer patients using radiophotoluminescence glass dosimeter
    Nose, T
    Koizumi, M
    Yoshida, K
    Nishiyama, K
    Sasaki, J
    Ohnishi, T
    Peiffert, D
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2005, 61 (03): : 945 - 953
  • [43] EFFECT OF ANISOTROPY CORRECTIONS ON THE DYNAMIC DOSE CALCULATIONS IN HIGH-DOSE-RATE (HDR) BRACHYTHERAPY
    CHO, SH
    MULLERRUNKEL, R
    PHYSICS IN MEDICINE AND BIOLOGY, 1994, 39 (07): : 1181 - 1188
  • [44] Open MR-Guided High-Dose-Rate (HDR) Prostate Brachytherapy: Feasibility and Initial Experiences Open MR-Guided High-Dose-Rate (HDR) Prostate Brachytherapy
    Lakosi, Ferenc
    Antal, Gergely
    Vandulek, Csaba
    Kovacs, Arpad
    Toller, Gabor L.
    Rakasz, Istvan
    Bajzik, Gabor
    Hadjiev, Janaki
    Bogner, Peter
    Repa, Imre
    PATHOLOGY & ONCOLOGY RESEARCH, 2011, 17 (02) : 315 - 324
  • [45] Characterization of MOSkin detector for in vivo skin dose measurement during megavoltage radiotherapy
    Jong, Wei Loong
    Wong, Jeannie Hsiu Ding
    Ung, Ngie Min
    Ng, Kwan Hoong
    Ho, Gwo Fuang
    Cutajar, Dean L.
    Rosenfeld, Anatoly B.
    JOURNAL OF APPLIED CLINICAL MEDICAL PHYSICS, 2014, 15 (05): : 120 - 132
  • [46] High-Dose-Rate (HDR) Brachytherapy for Facial Nonmelanoma Skin Cancer (NMSC) Using Custom-Made Molds and a Shortened Fractionation Schedule
    Amendola, B. E.
    Perez, N.
    Amendola, M. A.
    Fowler, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 87 (02): : S616 - S616
  • [47] Dosimetry of local failure with single dose 19 Gy high-dose-rate brachytherapy for prostate cancer
    Armstrong, Shreya
    Tsang, Yatman
    Lowe, Gerry
    Tharmalingam, Hannah
    Alonzi, Roberto
    Ostler, Peter
    Hughes, Robert
    Hoskin, Peter
    RADIOTHERAPY AND ONCOLOGY, 2021, 157 : 93 - 98
  • [48] Evaluation of Survival and Treatment Toxicity With High-Dose-Rate Brachytherapy With Cobalt 60 in Carcinoma of Cervix
    Rakhsha, Afshin
    Kashi, Amir Shahram Yousefi
    Hoseini, Seied Mohsen
    IRANIAN JOURNAL OF CANCER PREVENTION, 2015, 8 (04)
  • [49] High-Dose-Rate Prostate Brachytherapy Consistently Results in High Quality Dosimetry
    White, Evan C.
    Kamrava, Mitchell R.
    Demarco, John
    Park, Sang-June
    Wang, Pin-Chieh
    Kayode, Oluwatosin
    Steinberg, Michael L.
    Demanes, D. Jeffrey
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2013, 85 (02): : 543 - 548
  • [50] The role of endoluminal high-dose-rate (HDR) Brachytherapy for relapse bronchial carcinoma
    Hauswald, S. H.
    Rochet, N.
    Stoiber, E.
    Grehn, C.
    Hensley, F.
    Becker, H. D.
    Harms, W.
    Debus, J.
    STRAHLENTHERAPIE UND ONKOLOGIE, 2008, 184 : 129 - 129