Effect of adding Ar gas on the pulse height distribution of BF3-filled neutron detectors

被引:0
|
作者
M. Padalakshmi
A. M. Shaikh
机构
[1] Bhabha Atomic Research Centre,Solid State Physics Division
来源
Pramana | 2008年 / 71卷
关键词
Gas-filled proportional counters; BF; -filled neutron detectors; 29.40.-n; 29.40.Cs;
D O I
暂无
中图分类号
学科分类号
摘要
Boron trifluoride (BF3) proportional counters are used as detectors for thermal neutrons. They are characterized by high neutron sensitivity and good gamma discriminating properties. Most practical BF3 counters are filled with pure boron trifluoride gas enriched up to 96% 10B. But BF3 is not an ideal proportional counter gas. Worsening of plateau characteristics is observed with increasing radius due to impurities in gas. To overcome this problem, counters are filled with BF3 with an admixture of a more suitable gas such as argon. The dilution of BF3 with argon causes a decrease in detection efficiency, but the pulse height spectrum shows sharper peaks and more stable plateau characteristics than counters filled with pure BF3. The present investigations are undertaken to study the pulse height distribution and other important factors in BF3+Ar filled signal counters for neutron beam applications. Tests are performed with detectors with cylindrical geometry filled with BF3 gas enriched in 10B to 90%, and high purity Ar in different proportions. By analysing pulse height spectra, a value of 6.1 ± 0.2 has been obtained for the branching ratio of the 10B(n,α) reaction.
引用
收藏
页码:1177 / 1181
页数:4
相关论文
共 9 条
  • [1] Effect of adding Ar gas on the pulse height distribution of BF3-filled neutron detectors
    Padalakshmi, M.
    Shaikh, A. M.
    PRAMANA-JOURNAL OF PHYSICS, 2008, 71 (05): : 1177 - 1181
  • [2] A systematic study of the pulse height deficit in propane-filled gas ionization detectors
    Weijers, TDM
    Ophel, TR
    Timmers, H
    Elliman, RG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2002, 483 (03): : 676 - 688
  • [3] Origins of the residual pulse height deficit in propane-filled gas ionization detectors
    Weijers-Dall, TDM
    Timmers, H
    Elliman, RG
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2005, 550 (1-2): : 139 - 144
  • [4] Pulse-height defect of Ar + CF4 mixtures as a counting gas for fission-fragment detectors
    Peck, M.
    Gook, A.
    Enders, J.
    Hambsch, F. -J.
    Oberstedt, S.
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2019, 919 : 105 - 112
  • [5] DETECTION EFFICIENCY OF BARE AND MODERATED BF3-GAS-FILLED PROPORTIONAL COUNTERS FOR ISOTROPIC NEUTRON FLUXES
    YAMASHITA, M
    STEPHENS, LD
    SMITH, AR
    PATTERSON, HW
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY-TOKYO, 1966, 3 (08): : 343 - +
  • [6] Calculating the Pulse-Height Spectra of ITER Vertical Neutron Camera Diamond Detectors with Regard to the Plasma Ion Distribution Function
    Revyakin, P. A.
    Rodionov, R. N.
    Nemtsev, G. E.
    TECHNICAL PHYSICS, 2024, 69 (08) : 2426 - 2432
  • [7] Effect of temperature on performance of Boron Trifluoride (BF3) gas-based neutron proportional counters
    Desai, Shraddha S.
    Rao, Mala N.
    RADIATION MEASUREMENTS, 2021, 144
  • [8] Computer simulation study of correspondence between experimental and theoretical electron drift velocities in Ar gas .3. Effect of the initial electron pulse shape
    Satoh, K
    Itoh, H
    Sakai, Y
    Tagashira, H
    JOURNAL OF PHYSICS D-APPLIED PHYSICS, 1996, 29 (09) : 2390 - 2394
  • [9] Effect of the cyclic delivery of (hexafluoroacetylacetonate)Cu(I) X(3,3-dimethyl-1-butene) pulse and Ar purge gas on the low temperature copper metalorganic chemical vapor deposition
    Kim, K
    Tak, Y
    Yong, KJ
    JOURNAL OF VACUUM SCIENCE & TECHNOLOGY B, 2004, 22 (02): : 528 - 532