Influence of Ultrasound Settings on Carotid Biomarker Assessment by B-mode Image Processing

被引:0
|
作者
Martina Francesconi
Vincenzo Gemignani
Rachele Gherardini
Nicole Di Lascio
Francesco Faita
Lorenzo Ghiadoni
Rosa Maria Bruno
Elisabetta Bianchini
机构
[1] Italian National Research Council,Institute of Clinical Physiology
[2] University of Pisa,Department of Clinical and Experimental Medicine
[3] Université de Paris,Département de Pharmacologie
[4] Paris Cardiovascular Research Center – PARCC,INSERM, U970
来源
Artery Research | 2019年 / 25卷
关键词
Carotid biomarker; Carotid IMT; Carotid distension; Ultrasound settings; Semi-automatic software;
D O I
暂无
中图分类号
学科分类号
摘要
We investigated how ultrasound imaging setup may affect carotid parameters.Carotid parameters’ reproducibility was lower with high-gain values.Persistence filter leads to underestimation of diameter and distension.The scan projection seems to influence carotid parameter estimation.Image depth should be kept at the lowest attainable value for best repeatability.
引用
收藏
页码:139 / 144
页数:5
相关论文
共 50 条
  • [41] Quantitative Assessment of Tendon Backscatter Anisotropy in B-Mode Ultrasound
    Gao, Jing
    Rosander, Ashley
    Rubin, Jonathan M.
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2023, 49 (06): : 1408 - 1414
  • [42] B-MODE SONOGRAPHY OF THE CAROTID BIFURCATION
    TERWEY, B
    GAHBAUER, H
    MONTEMAYOR, M
    PROUSSALIS, A
    ZOLLNER, G
    ULTRASCHALL IN DER MEDIZIN, 1984, 5 (05): : 190 - 201
  • [43] B-MODE SONOGRAPHY OF CAROTID ARTERIES
    TOLLY, E
    DIETRICH, G
    SCHREYER, H
    RADIOLOGE, 1983, 23 (04): : 179 - 184
  • [44] Classification Approach for Measurement of Atherosclerosis Using B-Mode Ultrasound Carotid Images
    Carvalho, Catarina
    Rocha, Rui
    Campilho, Aurelio
    IMAGE ANALYSIS AND RECOGNITION, 2013, 7950 : 539 - 546
  • [45] Segmentation of the carotid intima-media region in B-mode ultrasound images
    Rocha, Rui
    Campilho, Aurelio
    Silva, Jorge
    Azevedo, Elsa
    Santos, Rosa
    IMAGE AND VISION COMPUTING, 2010, 28 (04) : 614 - 625
  • [46] Correlation between ultrasound B-mode images of carotid plaque and histological examination
    Jespersen, SK
    Gronholdt, MLM
    Wilhjelm, JE
    Wiebe, B
    Hansen, LK
    Sillesen, H
    1996 IEEE ULTRASONICS SYMPOSIUM, PROCEEDINGS, VOLS 1 AND 2, 1996, : 1065 - 1068
  • [47] EVALUATION OF A SCORING SYSTEM FOR EXTRACRANIAL CAROTID ATHEROSCLEROSIS EXTENT WITH B-MODE ULTRASOUND
    CROUSE, JR
    HARPOLD, GH
    KAHL, FR
    TOOLE, JF
    MCKINNEY, WM
    STROKE, 1986, 17 (02) : 270 - 275
  • [48] RELIABILITY OF B-MODE ULTRASOUND IN MEASURING SMALL CAROTID-ARTERY PLAQUES
    BOND, MG
    INSULL, W
    GARDIN, JF
    WILMOTH, SK
    CIRCULATION, 1984, 70 (04) : 162 - 162
  • [49] CORRELATION OF B-MODE ULTRASOUND IMAGING AND ARTERIOGRAPHY WITH PATHOLOGIC FINDINGS AT CAROTID ENDARTERECTOMY
    ODONNELL, TF
    ERDOES, L
    MACKEY, WC
    MCCULLOUGH, J
    SHEPARD, A
    HEGGERICK, P
    ISNER, J
    CALLOW, AD
    ARCHIVES OF SURGERY, 1985, 120 (04) : 443 - 449
  • [50] Motion synchronisation patterns of the carotid atheromatous plaque from B-mode ultrasound
    Golemati, Spyretta
    Patelaki, Eleni
    Gastounioti, Aimilia
    Andreadis, Ioannis
    Liapis, Christos D.
    Nikita, Konstantina S.
    SCIENTIFIC REPORTS, 2020, 10 (01)