Analysis of Data Measured with a Neutron Detector Based on a Boron-10 and Helium-3 Counter on a Source of Photoneutrons

被引:0
|
作者
Kuznetsov S.P. [1 ]
Meshkov I.V. [1 ]
Potashev S.I. [2 ]
Burmistrov Y.M. [2 ]
Karaevsky S.K. [2 ]
机构
[1] Lebedev Physical Institute, Russian Academy of Sciences, Moscow
[2] Institute for Nuclear Research, Russian Academy of Sciences, Moscow
关键词
D O I
10.3103/S1062873818060175
中图分类号
学科分类号
摘要
Data obtained on the IN-LUE photoneutron source at the Russian Academy of Sciences’ Institute for Nuclear Research are analyzed. The data are acquired using a position-sensitive neutron detector with an active 10B layer and a 3He SNM-18 counter. The efficiency of the 10B detector relative to the 3He counter ranges from 2 to 4% for different modes of accelerator operation. Waveforms of the 3He counter’s pulses are recorded using a built-in L-CARD L-783 multifunctional high speed signal processor with sampling frequencies of up to 3 MHz. The amplitude and time spectra of thermal neutrons are obtained from the waveforms using induced electromagnetic signals from the accelerator dump and neutron pulses. Using a cadmium mask with slits and a position-sensitive detector with a low (<10−7) sensitivity to electromagnetic interference and the gamma-ray background allows the spatial resolution of the10B detector to be determined and the contribution from neutrons with different energies to b estimated. © 2018, Allerton Press, Inc.
引用
收藏
页码:725 / 727
页数:2
相关论文
共 21 条
  • [1] Studying the Spatial Distribution of a Neutron Flux Using Detectors Based on Helium-3 and Boron-10
    Meshkov I.V.
    Potashev S.I.
    Afonin A.A.
    Burmistrov Y.M.
    Drachev A.I.
    Zuyev S.V.
    Karaevsky S.K.
    Kasparov A.A.
    Konobeevski E.S.
    Kuznetsov S.P.
    Marin V.N.
    Ponomarev V.N.
    Soloduhov G.V.
    Bulletin of the Russian Academy of Sciences: Physics, 2020, 84 (04) : 382 - 384
  • [2] Boron-10 Based Neutron Coincidence Counter for Safeguards
    Kouzes, Richard T.
    Ely, James H.
    Lintereur, Azaree T.
    Siciliano, Edward R.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2014, 61 (05) : 2608 - 2618
  • [3] Studying the Neutron Yield from a Target of a Compact Neutron Source on the LUE-8 Accelerator Using Helium-3 and Boron-10 Detectors
    Meshkov I.V.
    Kuznetsov S.P.
    Potashev I.S.
    Burmistrov Y.M.
    Karaevsky S.K.
    Solodukhov G.V.
    Bulletin of the Russian Academy of Sciences: Physics, 2018, 82 (6) : 728 - 730
  • [4] A NEUTRON DETECTOR BASED ON BORON-10 ENRICHED SCINTILLATING GLASSES
    Vu, Dat
    Dettmann, Makena
    Herrig, Victor
    Jacobsohn, Luiz G.
    Kielty, Matthew W.
    Wetzel, James
    Onel, Yasar
    Akgun, Ugur
    ADDITIVE MANUFACTURING AND STRATEGIC TECHNOLOGIES IN ADVANCED CERAMICS, 2016, 258 : 59 - 68
  • [5] Helium-3 and boron-10 concentration and depth measurements in alloys and semiconductors using NDP
    Ünlü, K
    Saglam, M
    Wehring, BW
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 1999, 422 (1-3): : 885 - 890
  • [6] Time- and energy-resolved effects in the boron-10 based multi-grid and helium-3 based thermal neutron detectors
    Backis, A.
    Khaplanov, A.
    Al Jebali, R.
    Ammer, R.
    Apostolidis, I
    Birch, J.
    Lai, C. C.
    Deen, P. P.
    Etxegarai, M.
    de Ruette, N.
    Ramos, J. Freita
    Foerster, D. F.
    Haettner, E.
    Hall-Wilton, R.
    Hamilton, D.
    Hoglund, C.
    Kadletz, P. M.
    Kanaki, K.
    Karnickis, E.
    Kirstein, O.
    Kolya, S.
    Kraujalyte, Z.
    Laloni, A.
    Livingston, K.
    Loehman, O.
    Maulerova, V
    Mauritzon, N.
    Mueller, F.
    Higuera, I. Lopez
    Richter, T.
    Robinson, L.
    Roth, R.
    Shetty, M.
    Taylor, J.
    Woracek, R.
    Xiong, W.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2021, 32 (03)
  • [7] Development of a D-D neutron spectrum detector based on helium-3 proportional counter
    Yuan, Guoliang
    Wen, Zuowei
    Feng, Lei
    Luo, Xiaobing
    Wei, Lingfeng
    Zhang, Jinwen
    Zhao, Wei
    Yang, Qingwei
    Liu, Yi
    REVIEW OF SCIENTIFIC INSTRUMENTS, 2023, 94 (11):
  • [8] Use of liquid helium-3 as a neutron converter for a semiconductor-based neutron detector
    Nakamura, T
    Katagiri, M
    Aratono, Y
    Kanno, I
    Hishiki, S
    Sugiura, O
    Murase, Y
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2004, 529 (1-3): : 399 - 401
  • [9] Boron-Coated Straw Detectors: a Novel Approach for Helium-3 Neutron Detector Replacement
    Lacy, Jeffrey L.
    Athanasiades, Athanasios
    Martin, Christopher S.
    Sun, Liang
    Vazquez-Flores, Gerson J.
    Lyons, Tom D.
    2010 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD (NSS/MIC), 2010, : 3971 - 3975
  • [10] Microstructured Semiconductor Neutron Detector (MSND)-based Helium-3 Replacement Technology
    Bellinger, Steven L.
    Fronk, Ryan G.
    Henson, Luke C.
    Ochs, Taylor R.
    Sobering, Timothy J.
    McGregor, Douglas S.
    2014 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2014,