Modern detectors for radiation monitors

被引:0
|
作者
A. V. Shumakov
A. S. Sviridov
S. V. Kolesnikov
机构
来源
Atomic Energy | 2011年 / 110卷
关键词
Light Output; Plastic Scintillator; Avalanche Photodiode; Good Energy Resolution; Gaseous Electron Multiplier;
D O I
暂无
中图分类号
学科分类号
摘要
The possibilities of using modern photon and neutron detectors for developing radiation monitors, specifically, LaBr3, Bi4Ge3O12, CdWO4, LiI, ZnO, Lu2SiO5(Ce), CdTe, and HgI2, microtubes from organic scintillators, nanomaterials, and detectors based on gaseous and solid-state electronic multipliers are examined. A comparison is made of conventional detectors based on NaI(Tl) and CsI(Tl), plastic scintillators, and 3He counters. The advantages of the new detectors are better energy resolution, high detection efficiency, low supply voltage, processing convenience, and cost. These detectors will increase the sensitivity of radiation monitors in monitoring unauthorized transport of nuclear and other radioactive materials, identify in real time the materials being monitored, and simplify the detecting apparatus and the development of monitors.
引用
收藏
页码:184 / 194
页数:10
相关论文
共 50 条
  • [31] Radionuclide Identification by Radiation Monitors
    Ya. V. Luzhanchuk
    Instruments and Experimental Techniques, 2018, 61 : 127 - 129
  • [32] The race for new radiation monitors
    Camanzi, B.
    Holmes-Siedle, A. G.
    NATURE MATERIALS, 2008, 7 (05) : 343 - 346
  • [33] Exposure - Are radiation monitors accurate?
    Edwards, R
    NEW SCIENTIST, 2000, 167 (2253) : 15 - 15
  • [34] The race for new radiation monitors
    B. Camanzi
    A. G. Holmes-Siedle
    Nature Materials, 2008, 7 : 343 - 345
  • [35] 10B+ZnS(Ag) as an alternative to 3He-based detectors for Radiation Portal Monitors
    Arlet Guzman-Garcia, Karen
    Rene Vega-Carrillo, Hector
    Gallego, Eduardo
    Antonio Gonzalez-Gonzalez, Juan
    Lorente, Aifredo
    Ibanez-Fernandez, Sviatoslav
    ICRS-13 & RPSD-2016, 13TH INTERNATIONAL CONFERENCE ON RADIATION SHIELDING & 19TH TOPICAL MEETING OF THE RADIATION PROTECTION AND SHIELDING DIVISION OF THE AMERICAN NUCLEAR SOCIETY - 2016, 2017, 153
  • [36] POST ACCIDENT RADIATION MONITORS
    LAUGHLIN, GJ
    KATHREN, RL
    HEALTH PHYSICS, 1983, 45 (01): : 199 - 199
  • [37] STANDARDIZATION OF PORTABLE RADIATION MONITORS
    DAVYDOV, AV
    GUSEINOV, AM
    EMELYANOV, NN
    MEASUREMENT TECHNIQUES, 1975, 18 (05) : 751 - 754
  • [38] Beam monitors for TESLA based on diamond strip detectors
    Bol, J
    Berdermann, E
    deBoer, W
    Grigoriev, E
    Hauler, F
    Jungermann, L
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (06) : 2999 - 3005
  • [39] Supervisory circuit monitors modern connection
    Simoes, JB
    Landeck, J
    EDN, 1998, 43 (08) : 117 - 117
  • [40] Boron-Coated Straw Detectors for Backpack Monitors
    Lacy, Jeffrey L.
    Athanasiades, Athanasios
    Martin, Christopher S.
    Sun, Liang
    Vazquez-Flores, Gerson J.
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (02) : 1111 - 1117