Gas Chromatography/Multiphoton Ionization/Mass Spectrometry of Polychlorinated Dibenzofurans Using Nanosecond and Femtosecond Lasers

被引:0
|
作者
Satoshi Yamaguchi
Tomohiro Uchimura
Totaro Imasaka
机构
[1] Kyushu University,Department of Applied Chemistry, Graduate School of Engineering
[2] Kyushu University,Division of Translational Research, Center for Future Chemistry
来源
Analytical Sciences | 2006年 / 22卷
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Gas chromatography/multiphoton ionization/time-of-flight mass spectrometry (GC/MPI/TOF-MS) using a femtosecond laser source has been developed and applied to analysis of an authentic sample containing five polychlorinated dibenzofurans (PCDFs). The ionization efficiency was substantially improved for compounds such as tetrachlorinated dibenzofuran (tetraCDF) and pentachlorinated dibenzofuran (pentaCDF) using a femtosecond laser, instead of a nanosecond laser currently used for this purpose. The relatively poor efficiencies in nanosecond ionization can be attributed to the short lifetimes of the singlet excited states that are efficiently relaxed to triplet levels by intersystem crossing. The detection limits for pentaCDF isomers, i.e., 1,2,3,8,9-pentaCDF (non-toxic) and 1,2,3,7,8-pentaCDF (toxic), were determined to be ca. 100 pg, when the femtosecond laser was employed. The present method has the potential for use in the detection and determination of toxic PCDD/Fs in exhaust gas from an incinerator, because of the high inherent selectivity of GC and the high sensitivity of MPI/TOF-MS.
引用
收藏
页码:1483 / 1487
页数:4
相关论文