Interferometric measurement using bimorph actuated staggered mirror (BASM) microsensor

被引:0
|
作者
Si-Hyung Lim
Hong Jae Yim
机构
[1] Kookmin University Jeongneung-dong,School of Mechanical and Automotive Engineering
[2] Sungbuk-gu,undefined
关键词
Interferometry; Bimorph; Physical sensor; Chemical sensor; Micro mirror; Optical diffraction;
D O I
暂无
中图分类号
学科分类号
摘要
For physical and chemical sensing applications, a bimorph actuated staggered mirror (BASM) microsensor was designed and fabricated by surface micromachining using a transparent quartz substrate. While the conventional cantilever sensors have angular deflection, BASM’s moving mirror performs piston-type pure vertical motion in response to environmental stimuli like temperature change and surface stress change due to molecular adsorption. Since the sensor itself has a fixed or reference mirror as well as a moving mirror, 1) an interferometric measurement is possible without an additional reference mirror in off-axis measurement setup, and 2) vibration measurement noise can be reduced. For preliminary test purposes, interferometric measurement using an optical setup was performed for temperature change. At He-Ne line (632.8 nm), a temperature change of ∼0.8 K caused a minimum-to-maximum interferometric light intensity change which corresponds to ∼144 nm shift of the moving mirror part. An optical diffraction analysis was performed and optimal device parameters were found to maximize the sensor sensitivity.
引用
收藏
相关论文
共 50 条
  • [31] INTERFEROMETRIC PHASE MEASUREMENT USING SPATIAL SYNCHRONOUS DETECTION
    WOMACK, KH
    OPTICAL ENGINEERING, 1984, 23 (04) : 391 - 395
  • [32] Optoacoustic imaging using interferometric measurement of surface displacement
    Carp, SA
    Guerra, A
    Duque, SQ
    Venugopalan, V
    APPLIED PHYSICS LETTERS, 2004, 85 (23) : 5772 - 5774
  • [33] High precision speed measurement by using interferometric techniques
    Rodriguez Avila, M. A.
    Ochoa Valiente, R.
    Garcia Trujillo, L. A.
    VII INTERNATIONAL CONGRESS OF ENGINEERING PHYSICS, 2015, 582
  • [34] Interferometric straightness measurement system using triangular prisms
    Zhang, JH
    Cai, LL
    OPTICAL ENGINEERING, 1998, 37 (06) : 1785 - 1789
  • [35] INTERFEROMETRIC STRAIGHTNESS MEASUREMENT SYSTEM USING A HOLOGRAPHIC GRATING
    YAMAUCHI, M
    MATSUDA, K
    OPTICAL ENGINEERING, 1994, 33 (04) : 1078 - 1083
  • [36] Beam cleanup of a 532-nm pulsed solid-state laser using a bimorph mirror
    雷翔
    许冰
    杨平
    董理治
    刘文劲
    晏虎
    ChineseOpticsLetters, 2012, 10 (02) : 48 - 51
  • [37] Beam cleanup of a 532-nm pulsed solid-state laser using a bimorph mirror
    Lei, Xiang
    Xu, Bing
    Yang, Ping
    Dong, Lizhi
    Liu, Wenjin
    Yan, Hu
    CHINESE OPTICS LETTERS, 2012, 10 (02)
  • [38] Laser beam focusing through the scattering medium using bimorph deformable mirror and spatial light modulator
    Galaktionov, Ilya
    Kudryashov, Alexis
    Sheldakova, Julia
    Nikitin, Alexander
    UNCONVENTIONAL AND INDIRECT IMAGING, IMAGE RECONSTRUCTION, AND WAVEFRONT SENSING 2019, 2019, 11135
  • [39] Direct Measurement of Intra-abdominal Pressures in a Horse by Using a Solid Microsensor
    Barrett, Elizabeth J.
    Munsterman, Amelia S.
    Albanese, Valeria
    Hanson, R. Reid
    JOURNAL OF EQUINE VETERINARY SCIENCE, 2013, 33 (11) : 1000 - 1003
  • [40] Measurement of crack closure behavior in steels using interferometric strain measurement system
    Kinefuchi, Masao
    Yokomaku, Toshinori
    Minokata, Yasuro
    R and D: Research and Development Kobe Steel Engineering Reports, 1995, 45 (03): : 39 - 42