Long-term radiographic results of the Saint Nabor non-cemented acetabular component

被引:0
|
作者
P. Schuster
S. Descamps
B. Bouillet
S. Boisgard
J. P. Levai
机构
[1] Clinique St Nabor,Department of Orthopaedic Surgery, Traumatology
[2] CHU Hôpital Gabriel Montpied,Department of Orthopaedic Surgery, Traumatology and Reconstructive Surgery
来源
European Journal of Orthopaedic Surgery & Traumatology | 2009年 / 19卷
关键词
Hybrid total hip arthroplasty; Uncemented acetabular cup; Long-term radiographic review;
D O I
暂无
中图分类号
学科分类号
摘要
Between August 1985 and December 1987, a total of 303 total hip arthroplasties were performed in 275 patients using the Saint Nabor press-fit acetabular component. Radiographic evaluations were performed at an average of 18.1 years for 95 hips in 86 patients. Migration analyses of the femoral and acetabular components were also performed. Seventeen patients had early postoperative complications: aseptic loosening in 1 patient, luxation in 16 patients. Twenty-five patients (25 hips) had late postoperative complications involving aseptic loosening: 21 femoral components, 2 acetabular components, and 2 cases of both components. The average acetabular component migration in the horizontal direction was 1.71 mm and was 0.31 mm in the vertical direction. The Kaplan–Meier survival rate of the acetabular component at 19 years was 95%.
引用
收藏
页码:309 / 314
页数:5
相关论文
共 50 条
  • [21] THE LONG-TERM RESULTS OF INNOMINATE OSTEOTOMY FOR ACETABULAR DYSPLASIA
    WILKINSON, JA
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 1987, 69 (05): : 850 - 850
  • [22] LONG-TERM RESULTS OF ASEPTIC CEMENTED CHARNLEY REVISIONS
    GARCIACIMBRELO, E
    MUNUERA, L
    DIEZVAZQUEZ, V
    JOURNAL OF ARTHROPLASTY, 1995, 10 (02): : 121 - 131
  • [23] LONG-TERM RESULTS OF CEMENTED TOTAL KNEE ARTHROPLASTY
    VINCE, KG
    INSALL, JN
    ORTHOPEDIC CLINICS OF NORTH AMERICA, 1988, 19 (03) : 575 - 580
  • [24] The long-term outcome of the cemented Weber acetabular component in total hip replacement using a second-generation cementing technique
    de Jong, P. T.
    de Man, F. H. R.
    Haverkamp, D.
    Marti, R. K.
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2009, 91B (01): : 31 - 36
  • [25] Cemented or uncemented acetabular fixation in combination with the Exeter Universal cemented stem LONG-TERM SURVIVAL TO 18 YEARS
    Gwynne-Jones, D. P.
    Gray, A. R.
    BONE & JOINT JOURNAL, 2020, 102B (04): : 414 - 422
  • [26] The Long-Term Results of the Original Exeter Polished Cemented Femoral Component A Follow-up Report
    Ling, Robin S. M.
    Charity, John
    Lee, A. J. Clive
    Whitehouse, Sarah L.
    Timperley, A. John
    Gie, Graham A.
    JOURNAL OF ARTHROPLASTY, 2009, 24 (04): : 511 - 517
  • [27] LONG-TERM RESULTS AFTER CONSERVATIVE TREATMENT OF ACETABULAR FRACTURES
    MARTINEK, H
    EGKHER, E
    FASOL, P
    UNFALLHEILKUNDE-TRAUMATOLOGY, 1978, 81 (01): : 1 - 5
  • [28] LONG-TERM RESULTS OF CEMENTED TOTAL HIP-ARTHROPLASTY
    EFTEKHAR, NS
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1987, (225) : 207 - 217
  • [29] LONG-TERM RESULTS OF CEMENTED TOTAL HIP-REPLACEMENT
    MOLLENHOFF, G
    DAVID, A
    WALZ, M
    GRAF, M
    MUHR, G
    ZENTRALBLATT FUR CHIRURGIE, 1995, 120 (09): : 716 - 720
  • [30] Radiographic analysis of humeral stress shielding after total shoulder arthroplasty with non-cemented stem
    Durchholz, H.
    Spormann, C.
    Flury, M.
    Simmen, B. R.
    Schwyzer, H. K.
    Goldhahn, J.
    Kolling, C.
    SWISS MEDICAL WEEKLY, 2010, 140 (23-24) : 15S - 15S