Long-term radiographic results of the Saint Nabor non-cemented acetabular component

被引:0
|
作者
P. Schuster
S. Descamps
B. Bouillet
S. Boisgard
J. P. Levai
机构
[1] Clinique St Nabor,Department of Orthopaedic Surgery, Traumatology
[2] CHU Hôpital Gabriel Montpied,Department of Orthopaedic Surgery, Traumatology and Reconstructive Surgery
关键词
Hybrid total hip arthroplasty; Uncemented acetabular cup; Long-term radiographic review;
D O I
暂无
中图分类号
学科分类号
摘要
Between August 1985 and December 1987, a total of 303 total hip arthroplasties were performed in 275 patients using the Saint Nabor press-fit acetabular component. Radiographic evaluations were performed at an average of 18.1 years for 95 hips in 86 patients. Migration analyses of the femoral and acetabular components were also performed. Seventeen patients had early postoperative complications: aseptic loosening in 1 patient, luxation in 16 patients. Twenty-five patients (25 hips) had late postoperative complications involving aseptic loosening: 21 femoral components, 2 acetabular components, and 2 cases of both components. The average acetabular component migration in the horizontal direction was 1.71 mm and was 0.31 mm in the vertical direction. The Kaplan–Meier survival rate of the acetabular component at 19 years was 95%.
引用
收藏
页码:309 / 314
页数:5
相关论文
共 50 条
  • [1] Long-term radiographic results of the Saint Nabor non-cemented acetabular component
    Schuster, P.
    Descamps, S.
    Bouillet, B.
    Boisgard, S.
    Levai, J. P.
    EUROPEAN JOURNAL OF ORTHOPAEDIC SURGERY AND TRAUMATOLOGY, 2009, 19 (05): : 309 - 314
  • [2] Long-term radiographic assessment of cemented polyethylene acetabular cups
    Williams, Sophie
    Isaac, Graham
    Porter, Neil
    Fisher, John
    Older, John
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2008, 466 (02) : 366 - 372
  • [3] Cementless acetabular component St. Nabor. clinical and radiographic results after medium term follow-up.
    Kirschner, P
    Kreutz, A
    ZEITSCHRIFT FUR ORTHOPADIE UND IHRE GRENZGEBIETE, 2000, 138 (04): : 306 - 310
  • [4] BIOMECHANICAL ANALYSIS OF NON-CEMENTED THREADED ACETABULAR CUPS
    SCHRODER, DQ
    LEE, RW
    VOLZ, RG
    CLINICAL RESEARCH, 1988, 36 (01): : A143 - A143
  • [5] Performance of Non-Cemented, Hemispherical, Rim-Fit, Hydroxyapatite Coated Acetabular Component
    John, Thomas K.
    Ghosh, Gaurav
    Ranawat, Chitranjan S.
    Ranawat, Amar S.
    Meftah, Morteza
    JOURNAL OF ARTHROPLASTY, 2015, 30 (12): : 2233 - 2236
  • [6] Osteolytic lesions in the acetabular component of non-cemented total hip prosthesis: Plain film and CT evaluation
    Seo, GS
    Monu, JUV
    Tamez-Pena, J
    Parker, KJ
    Schwarz, EM
    Boyd, AD
    RADIOLOGY, 2001, 218 (02) : 612 - 612
  • [7] INFLUENCE OF ACETABULAR COMPONENT POSITION IN NON-CEMENTED TOTAL HIP-ARTHROPLASTY - A RADIOLOGIC AND CLINICAL-STUDY
    WYKMAN, A
    SANJAY, BKS
    SODERLUND, V
    GOLDIE, I
    ACTA RADIOLOGICA, 1988, 29 (06) : 746 - 748
  • [8] Long-term results of revision total hip arthroplasty with a cemented femoral component
    Pallaver, Armin
    Pallaver, A.
    Zwicky, L.
    Ochsner, P. E.
    Clauss, M.
    SWISS MEDICAL WEEKLY, 2017, 147 : 15S - 15S
  • [9] Long-term results of revision total hip arthroplasty with a cemented femoral component
    Armin Pallaver
    Lukas Zwicky
    Lilianna Bolliger
    Hans Bösebeck
    Isabella Manzoni
    Sabine Schädelin
    Peter E. Ochsner
    Martin Clauss
    Archives of Orthopaedic and Trauma Surgery, 2018, 138 : 1609 - 1616
  • [10] Long-term results of revision total hip arthroplasty with a cemented femoral component
    Pallaver, Armin
    Zwicky, Lukas
    Bolliger, Lilianna
    Boesebeck, Hans
    Manzoni, Isabella
    Schadelin, Sabine
    Ochsner, Peter E.
    Clauss, Martin
    ARCHIVES OF ORTHOPAEDIC AND TRAUMA SURGERY, 2018, 138 (11) : 1609 - 1616