Vessel-selective 4D-MR angiography using super-selective pseudo-continuous arterial spin labeling may be a useful tool for assessing brain AVM hemodynamics

被引:0
|
作者
Osamu Togao
Makoto Obara
Michael Helle
Koji Yamashita
Kazufumi Kikuchi
Daichi Momosaka
Yoshitomo Kikuchi
Ataru Nishimura
Koichi Arimura
Tatsuhiro Wada
Hiroo Murazaki
Koji Iihara
Marc Van Cauteren
Akio Hiwatashi
机构
[1] Kyushu University,Department of Clinical Radiology, Graduate School of Medical Sciences
[2] Philips Japan,Department of Neurosurgery, Graduate School of Medical Sciences
[3] Philips Research,Division of Radiology, Department of Medical Technology
[4] Kyushu University,Department of Molecular Imaging & Diagnosis, Graduate School of Medical Sciences
[5] Kyushu University Hospital,undefined
[6] Kyushu University,undefined
来源
European Radiology | 2020年 / 30卷
关键词
Magnetic resonance imaging; Magnetic resonance angiography; Arteriovenous malformations; Brain;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:6452 / 6463
页数:11
相关论文
共 16 条
  • [11] Perfusion measurement in brain gliomas using velocity-selective arterial spin labeling: comparison with pseudo-continuous arterial spin labeling and dynamic susceptibility contrast MRI
    Qu, Yaoming
    Kong, Dexia
    Wen, Haitao
    Ou, Xiaochan
    Rui, Qihong
    Wang, Xianlong
    Lin, Doris D.
    Qin, Qin
    Wen, Zhibo
    EUROPEAN RADIOLOGY, 2022, 32 (05) : 2976 - 2987
  • [12] Perfusion measurement in brain gliomas using velocity-selective arterial spin labeling: comparison with pseudo-continuous arterial spin labeling and dynamic susceptibility contrast MRI
    Yaoming Qu
    Dexia Kong
    Haitao Wen
    Xiaochan Ou
    Qihong Rui
    Xianlong Wang
    Doris D. Lin
    Qin Qin
    Zhibo Wen
    European Radiology, 2022, 32 : 2976 - 2987
  • [13] Noncontrast dynamic 3D intracranial MR angiography using pseudo-continuous arterial spin labeling (PCASL) and accelerated 3D radial acquisition
    Wu, Huimin
    Block, Walter F.
    Turski, Patrick A.
    Mistretta, Charles A.
    Rusinak, David J.
    Wu, Yijing
    Johnson, Kevin M.
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2014, 39 (05) : 1320 - 1326
  • [14] Non-contrast enhanced 4D intracranial MR angiography based on pseudo-continuous arterial spin labeling with the keyhole and view-sharing technique
    Obara, Makoto
    Togao, Osamu
    Beck, Gabriele M.
    Shibukawa, Shuhei
    Okuaki, Tomoyuki
    Yoneyama, Masami
    Nakamura, Masanobu
    Honda, Hiroshi
    Van Cauteren, Marc
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (02) : 719 - 725
  • [15] Vessel-Selective 4D-MRA Using Superselective Pseudocontinuous Arterial Spin-Labeling with Keyhole and View-Sharing for Visualizing Intracranial Dural AVFs
    Togao, O.
    Obara, M.
    Kikuchi, K.
    Helle, M.
    Arimura, K.
    Nishimura, A.
    Wada, T.
    Murazaki, H.
    Van Cauteren, M.
    Hiwatashi, A.
    Ishigami, K.
    AMERICAN JOURNAL OF NEURORADIOLOGY, 2022, 43 (03) : 368 - 375
  • [16] Improved temporal resolution and acceleration on 4D-MR angiography based on superselective pseudo-continuous arterial spin labeling combined with CENTRA-keyhole and view-sharing (4D-S-PACK) using an interpolation algorithm on the temporal axis and compressed sensing-sensitivity encoding (CS-SENSE)
    Murazaki, Hiroo
    Wada, Tatsuhiro
    Togao, Osamu
    Obara, Makoto
    Helle, Michael
    Kobayashi, Kouji
    Ishigami, Kousei
    Kato, Toyoyuki
    MAGNETIC RESONANCE IMAGING, 2024, 109 : 1 - 9