Automatic Identification of Systolic Time Intervals in Seismocardiogram

被引:0
|
作者
Ghufran Shafiq
Sivanagaraja Tatinati
Wei Tech Ang
Kalyana C. Veluvolu
机构
[1] School of Electronics Engineering,
[2] Kyungpook National University,undefined
[3] School of Mechanical and Aerospace Engineering,undefined
[4] Nanyang Technological University,undefined
来源
关键词
D O I
暂无
中图分类号
学科分类号
摘要
Continuous and non-invasive monitoring of hemodynamic parameters through unobtrusive wearable sensors can potentially aid in early detection of cardiac abnormalities, and provides a viable solution for long-term follow-up of patients with chronic cardiovascular diseases without disrupting the daily life activities. Electrocardiogram (ECG) and siesmocardiogram (SCG) signals can be readily acquired from light-weight electrodes and accelerometers respectively, which can be employed to derive systolic time intervals (STI). For this purpose, automated and accurate annotation of the relevant peaks in these signals is required, which is challenging due to the inter-subject morphological variability and noise prone nature of SCG signal. In this paper, an approach is proposed to automatically annotate the desired peaks in SCG signal that are related to STI by utilizing the information of peak detected in the sliding template to narrow-down the search for the desired peak in actual SCG signal. Experimental validation of this approach performed in conventional/controlled supine and realistic/challenging seated conditions, containing over 5600 heart beat cycles shows good performance and robustness of the proposed approach in noisy conditions. Automated measurement of STI in wearable configuration can provide a quantified cardiac health index for long-term monitoring of patients, elderly people at risk and health-enthusiasts.
引用
收藏
相关论文
共 50 条
  • [41] SYSTOLIC TIME INTERVALS IN INFANTS WITH HEART FAILURE
    PARK, S
    DIMICH, I
    STEINFEL.L
    CIRCULATION, 1970, 42 (04) : II31 - &
  • [42] PDA DIAGNOSIS BY SYSTOLIC-TIME INTERVALS
    DONNER, RM
    SAPIRE, D
    BLACK, I
    PEDIATRIC RESEARCH, 1980, 14 (04) : 443 - 443
  • [43] SYSTOLIC TIME INTERVALS IN HEART FAILURE IN MAN
    WEISSLER, AM
    HARRIS, WS
    SCHOENFE.CD
    CIRCULATION, 1968, 37 (02) : 149 - &
  • [44] STUDY TO ANALYSIS OF SYSTOLIC-TIME INTERVALS
    ERBEL, R
    BELZ, GG
    ZEITSCHRIFT FUR KARDIOLOGIE, 1977, 66 (08): : 433 - 435
  • [45] SYSTOLIC TIME INTERVALS: EFFECT OF MENTAL ARITHMETICS
    Krohova, J.
    Czippelova, B.
    Turianikova, Z.
    Lazarova, Z.
    Wiszt, R.
    Javorka, M.
    ACTA PHYSIOLOGICA, 2017, 221 : 120 - 120
  • [46] SYSTOLIC TIME INTERVALS IN ACUTE MYOCARDIAL INFARCTION
    DRAGULESCU, SI
    GAVRILESCU, S
    CRISTODORESCU, R
    REVUE ROUMAINE DE MEDECINE INTERNE, 1974, 11 (02): : 191 - 206
  • [47] CONFOUNDING FACTORS FOR SYSTOLIC-TIME INTERVALS
    MAINTZ, G
    SCHNEIDER, WD
    GIERKE, E
    ZEITSCHRIFT FUR KLINISCHE MEDIZIN-ZKM, 1986, 41 (03): : 207 - 209
  • [48] Systolic Time Intervals and New Measurement Methods
    Kouhyar Tavakolian
    Cardiovascular Engineering and Technology, 2016, 7 : 118 - 125
  • [49] DETERMINANTS OF SYSTOLIC TIME INTERVALS IN HUMAN HEART
    FLESSAS, AP
    POMPOSIE.JC
    CONNELLY, GP
    RYAN, TJ
    JOURNAL OF CLINICAL INVESTIGATION, 1971, 50 (06): : A32 - &
  • [50] EFFECT OF HALOTHANE ON SYSTOLIC-TIME INTERVALS
    HASBROUCK, JD
    COLEMAN, CC
    ANESTHESIA AND ANALGESIA, 1977, 56 (04): : 522 - 526