Three-dimensional echocardiography in the diagnosis of pacemaker lead perforation

被引:0
|
作者
Akinori Sugano
Yoshihiro Seo
Akiko Atsumi
Masayoshi Yamamoto
Tomoko Machino-Ohtuska
Ryo Kawamura
Hideki Nakajima
Tomoko Ishizu
Kazutaka Aonuma
机构
[1] University of Tsukuba,Cardiovascular Division
[2] University of Tsukuba Hospital,Department of Clinical Laboratory
关键词
Three-dimensional echocardiography; Implantable cardiac device; Complication; Lead perforation;
D O I
10.1007/s12574-012-0140-2
中图分类号
学科分类号
摘要
Recently, due to increases in the number of cardiac device implantations, especially implantable cardioverter-defibrillators and cardiac resynchronization therapy, device complications have been experienced more frequently. Myocardial perforation of an implanted lead is one of the most severe complications. We report a case of ventricular lead perforation clearly visualized by 3-dimensional echocardiography, which was not identified by 2-dimensional echocardiography.
引用
收藏
页码:141 / 142
页数:1
相关论文
共 50 条
  • [21] Utility of Three-Dimensional Transesophageal Echocardiography in the Diagnosis of Valvular Perforations
    Thompson, Keith A.
    Shiota, Takahiro
    Tolstrup, Kirsten
    Gurudevan, Swaminatha V.
    Siegel, Robert J.
    AMERICAN JOURNAL OF CARDIOLOGY, 2011, 107 (01): : 100 - 102
  • [22] Three-dimensional fetal echocardiography
    Nelson, TR
    PROGRESS IN BIOPHYSICS & MOLECULAR BIOLOGY, 1998, 69 (2-3): : 257 - 272
  • [23] Dynamic three-dimensional echocardiography
    Grad. School of Information Science, Nara Inst. of Science and Technology, Takayama 8916-5, Nara 630-0101, Japan
    Japanese Journal of Applied Physics, Part 1: Regular Papers and Short Notes and Review Papers, 2000, 39 (08): : 5028 - 5031
  • [24] Subacute right ventricular pacemaker lead perforation: evaluation by echocardiography and cardiac CT
    Boxma R.P.J.
    Kolff-Kamphuis M.G.M.
    Gevers R.M.M.
    Boulaksil M.
    Journal of Echocardiography, 2017, 15 (4) : 188 - 190
  • [25] Three-dimensional echocardiography - Foreword
    Crawford, Michael H.
    CARDIOLOGY CLINICS, 2007, 25 (02) : XI - XI
  • [26] Three-dimensional echocardiography - Preface
    Gill, Edward A.
    Nanda, Navin C.
    Lang, Roberto M.
    CARDIOLOGY CLINICS, 2007, 25 (02) : XIII - XIV
  • [27] Dynamic three-dimensional echocardiography
    Matsusaka, K
    Doi, M
    Oshiro, O
    Chihara, K
    JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 2000, 39 (08): : 5028 - 5031
  • [28] Anterior mitral leaflet perforation identified by real time three-dimensional transesophageal echocardiography
    Cheng, Hsiao-Liang
    Cheng, Ya-Jung
    Lai, Chia-Hsin
    CARDIOLOGY JOURNAL, 2012, 19 (01) : 89 - 91
  • [29] The added value of three-dimensional echocardiography in the late diagnosis of a pacemaker complication in a patient with severe congestive heart failure: a case report
    Baldea, Sorina Mihaila
    Velcea, Andreea Elena
    Siliste, Calin
    Vinereanu, Dragos
    EUROPEAN HEART JOURNAL-CASE REPORTS, 2019, 3 (01)
  • [30] Severe tricuspid regurgitation due to entrapment of the anterior leaflet of the valve by a permanent pacemaker lead: Role of real time three-dimensional echocardiography
    Nucifora, Gaetano
    Badano, Luigi P.
    Allocca, Giuseppe
    Gianfagna, Pasquale
    Proclemer, Alessandro
    Cinello, Margherita
    Fioretti, Paolo M.
    ECHOCARDIOGRAPHY-A JOURNAL OF CARDIOVASCULAR ULTRASOUND AND ALLIED TECHNIQUES, 2007, 24 (06): : 649 - 652