Effects of External Oscillations on Cocurrently Flowing Steam–Water in Pipes

被引:0
|
作者
Atta Ullah
Afrasyab Khan
Khairuddin Sanaullah
Hassan Ali Ghazwani
Taranenko Pavel Alexandrovich
机构
[1] Pakistan Institute of Engineering & Applied Sciences (PIEAS),Department of Chemical Engineering
[2] South Ural State University (SUSU),Institute of Engineering and Technology, Department of Hydraulics and Hydraulic and Pneumatic Systems
[3] University Malaysia Sarawak (UNIMAS),Department of Chemical Engineering and Energy Sustainability
[4] Jazan University,Department of Mechanical Engineering
[5] South Ural State University,Research Institute of Mechanical Engineering, Department of Vibration Testing and Equipment Condition Monitoring
关键词
Steam–water flow; External oscillations; Hydrodynamics; Velocity and temperature;
D O I
暂无
中图分类号
学科分类号
摘要
引用
收藏
页码:1101 / 1113
页数:12
相关论文
共 50 条
  • [31] The Effects of Chlorinated Water on Polyethylene Pipes
    Eng, Jerry
    Sassi, Thomas
    Steele, Thomas
    Vitarelli, Giacomo
    PLASTICS ENGINEERING, 2011, 67 (09) : 18 - +
  • [32] PRESSURE DROP OF BOILING SUBCOOLED WATER AND STEAM-WATER MIXTURES FLOWING IN HEATED CHANNELS
    TARASOVA, NV
    LEONTIEV, AI
    HLOPUSHI.VI
    ORLOV, VM
    CHEMICAL ENGINEERING PROGRESS, 1966, 62 (08) : 86 - &
  • [33] Investigation of the Heat-Insulation Properties of the Steam-Water Gap in the Downcomer Pipes of a Steam Generator
    Semchenkov, A. A.
    Novosel'skii, O. Yu.
    Lemekhov, Yu. V.
    Khizhnyak, A. G.
    Shpanskii, S. V.
    Shishov, V. P.
    ATOMIC ENERGY, 2014, 115 (05) : 294 - 299
  • [34] Investigation of the Heat-Insulation Properties of the Steam-Water Gap in the Downcomer Pipes of a Steam Generator
    A. A. Semchenkov
    O. Yu. Novosel’skii
    Yu. V. Lemekhov
    A. G. Khizhnyak
    S. V. Shpanskii
    V. P. Shishov
    Atomic Energy, 2014, 115 : 294 - 299
  • [35] THERMAL FATIGUE CRACKING DUE TO INTERMITTENTLY FLOWING DRAIN WATER IN STEAM PIPING
    Koki, Saito
    Tomohiro, Watanabe
    PROCEEDINGS OF THE ASME 2020 PRESSURE VESSELS & PIPING CONFERENCE (PVP2020), VOL 8, 2020,
  • [36] OSCILLATORY FLOWS INDUCED BY DIRECT CONTACT CONDENSATION OF FLOWING STEAM WITH INJECTED WATER
    AKIMOTO, H
    TANAKA, Y
    KOZAWA, Y
    INOUE, A
    AOKI, S
    JOURNAL OF NUCLEAR SCIENCE AND TECHNOLOGY, 1985, 22 (04) : 269 - 283
  • [37] Water rinse and flowing steam to kill Campylobacter on broiler transport coop flooring
    Berrang, M. E.
    Meinersmann, R. J.
    Cox, N. A.
    Adams, E. S.
    FOOD CONTROL, 2020, 114
  • [38] HYDRAULIC RESISTANCE WITH A STEAM-WATER MIXTURE FLOWING IN A VERTICAL HEATED TUBE
    TARASOVA, NV
    LEONTEV, AI
    HIGH TEMPERATURE, 1965, 3 (01) : 102 - &
  • [39] The influence of coating the insides of cement pipes with inertol on the scale of conductive resistence, while water is flowing through the aforementioned pipes.
    Stuckle, R
    ZEITSCHRIFT DES VEREINES DEUTSCHER INGENIEURE, 1914, 58 : 796 - 798
  • [40] Water mains and distribution pipes in soil - external corrosion and protection methods
    Camitz, G