Structural Performance of Welded Built-Up Mega Composite Columns Subject to Compressive Force and Moment

被引:0
|
作者
Sun-Hee Kim
Sung-Mo Choi
机构
[1] University of Seoul,Department of Architectural Engineering
关键词
Concrete-filled steel tubes; Built-up section; Composite column; With-thickness ratio; Buckling;
D O I
暂无
中图分类号
学科分类号
摘要
The width thickness ratio of a concrete-filled steel tube column is limited in order to prevent the local buckling of the tube. Determined by column width and steel tube thickness, width-thickness ratio decides whether the cross-section is compact, non-compact or slender. Different compressive strength formulas are applied depending on the type of the cross-section. This study suggests the shape of binding frames which are placed at a constant distance inside the steel tube of a mega column having large cross-sections to improve the composite effect and confinement effect. Structural tests are conducted on 9 welded built-up and generic CFT columns with different steel thicknesses to evaluate their structural performance under compressive force and moment applied simultaneously. The maximum load of the welded built-up specimens with compact, non-compact and slender cross-sections is approximately 38%, 30% and 20% higher when compared with their generic CFT counterparts. While the effective stiffness of the members of concrete-filled composite columns is calculated by one formula, the difference among the specimens is greater than 10% depending on the width-thickness ratio. Therefore, it is deemed that effective stiffness needs to be categorized depending on the width-thickness ratio as in the case of compressive strength and bending strength.
引用
收藏
页码:548 / 558
页数:10
相关论文
共 50 条
  • [41] AN INVESTIGATION INTO THE INFLUENCE OF WELD INDUCED RESIDUAL STRESSES ON THE STRUCTURAL BEHAVIOUR OF BUILT-UP EN 1.4003 COLUMNS
    Klopper, Johan J.
    Laubscher, Rudolph F.
    IMECE2009, VOL 4, 2010, : 399 - 408
  • [42] Compressive behavior of novel cold-formed steel built-up closed L-shaped section columns
    Jiang, Liqiang
    He, Jianguang
    Ma, Xiaoming
    Hu, Yi
    Chen, Zongping
    Zhang, Zhibin
    Yang, Hua
    JOURNAL OF BUILDING ENGINEERING, 2024, 86
  • [43] Compressive behavior of built-up open-section columns consisting of four cold-formed steel channels
    Nie, Shaofeng
    Zhao, Cunqing
    Liu, Zhe
    Han, Yong
    Zhou, Tianhua
    Wu, Hanheng
    STEEL AND COMPOSITE STRUCTURES, 2022, 45 (06): : 907 - 929
  • [44] Axial compressive behavior of cold-formed steel built-up box-shape columns with longitudinal stiffeners
    Yang, Jingjie
    Luo, Kai
    Wang, Weiyong
    Shi, Yu
    Li, Haifeng
    JOURNAL OF CONSTRUCTIONAL STEEL RESEARCH, 2024, 212
  • [45] Compressive behavior of built-up double-box columns consisting of four cold-formed steel channels
    Nie, Shaofeng
    Zhou, Tianhua
    Eatherton, Matthew R.
    Li, Jiang
    Zhang, Yang
    ENGINEERING STRUCTURES, 2020, 222 (222)
  • [46] Structural behaviour of cold-formed steel built-up closed section beam-columns
    Li, Qiu-Yun
    Young, Ben
    THIN-WALLED STRUCTURES, 2022, 181
  • [47] Mechanical Performance of Built-Up Columns Composed of Four Cold-Formed Square Steel Tubes
    Chen, Xiaomiao
    Xia, Junwu
    Xu, Bo
    Ma, Renwei
    APPLIED SCIENCES-BASEL, 2019, 9 (06):
  • [48] Reliability and Fire Performance of Built-up (Battened) Cold-formed Steel Columns: Numerical study
    Zhao, Yang
    EKSPLOATACJA I NIEZAWODNOSC-MAINTENANCE AND RELIABILITY, 2025, 27 (02):
  • [49] Influence of geopolymer foam concrete on the mechanical performance of cold-formed steel built-up columns
    Li, Yanchun
    Wei, Jiahong
    Han, Aihong
    Xu, Yun
    Qiao, Menghui
    He, Dazhi
    CASE STUDIES IN CONSTRUCTION MATERIALS, 2025, 22
  • [50] Long-term behavior and strength of partially encased composite columns made with built-up steel shapes
    Chicoine, T
    Massicotte, B
    Tremblay, R
    JOURNAL OF STRUCTURAL ENGINEERING-ASCE, 2003, 129 (02): : 141 - 150