共 50 条
Persistent type III cavity-spilling coronary perforation due to covered stent malapposition
被引:5
|作者:
McCormick L.M.
[1
]
Ko B.S.
[1
]
Zaman S.
[1
]
Ahmar W.
[1
]
Meredith I.T.
[1
,2
]
机构:
[1] MonashHEART, Monash Medical Centre, Southern Health, 246 Clayton Road, Clayton, 3168, VIC
[2] MonashHEART, Monash Medical Centre, Monash Health and Monash University, Melbourne
关键词:
Cavity-spilling perforation;
Malapposition;
PTFE-covered stent;
D O I:
10.1007/s12928-015-0346-0
中图分类号:
学科分类号:
摘要:
Coronary perforations are a rare but potentially catastrophic complication of percutaneous coronary intervention. We report a rare case of a large cavity-spilling perforation from the left anterior descending coronary artery into the left ventricle, which was successfully treated with a covered stent. However, repeating angiography 1 week later demonstrated persistence of the perforation due to stent malapposition. © 2015, Japanese Association of Cardiovascular Intervention and Therapeutics.
引用
收藏
页码:269 / 274
页数:5
相关论文