Analysis of four methods of measuring three-dimensional pelvic tilt in the lateral decubitus position

被引:0
|
作者
Meredith Stadnyk
Tao Liu
Fatemeh Fallahi Arezodar
Lindsey Westover
Jaime A. Carvajal Alba
Edward Masson
Lauren Beaupre
Jacob L. Jaremko
Marwan El-Rich
机构
[1] University of Alberta,Department of Biomedical Engineering
[2] University of Alberta,Department of Mechanical Engineering
[3] Khalifa University,Healthcare Engineering Innovation Center, Department of Mechanical Engineering
[4] University of Alberta,Department of Civil and Environmental Engineering
[5] University of Miami,Department of Orthopaedics
[6] University of Alberta,Department of Surgery
[7] University of Alberta,Department of Physical Therapy
[8] University of Alberta,Department of Radiology and Diagnostic Imaging
关键词
Total hip arthroplasty; Pelvic rotations; Lateral decubitus; Pelvic angle;
D O I
暂无
中图分类号
学科分类号
摘要
Proper alignment of acetabular implantation is necessary for good patient outcomes and preventing complications or additional surgeries in total hip arthroplasty (THA). Rotation of the pelvis in lateral decubitus (LD) is typically not accounted for as surgeons use the surgery table as a reference plane to align implants. This study compared four techniques to measure 3D pelvic rotations in LD position using computer models. CT scans of 19 subjects in LD position were used to create 3D pelvis models. Pelvic rotations were measured by three users using four techniques: landmark (LM), defined plane (DP), anterior pelvic plane (APP), and plane of best symmetry (POBS) methods. Measurements were analysed for intra-user reliability and relationships between methods were assessed using intraclass correlation coefficient, standard error of measurement, and coefficient of determination. The POBS method exhibited the highest inter-observer reliability and is recommended as a new measurement technique to measure pelvic rotations before THA surgery. The LM method exhibited low reliability but may be suitable for expert users familiar with pelvic landmarks. The APP method should only be used when the patients’ APP planes are known in neutral standing and side-lying postures. The DP method is not recommended due to substantial individual variability.
引用
收藏
页码:2387 / 2396
页数:9
相关论文
共 50 条
  • [21] Stress analysis by three-dimensional photoelastic methods
    Drucker, DC
    Mindlin, RD
    JOURNAL OF APPLIED PHYSICS, 1940, 11 (11) : 724 - 732
  • [22] Efficacy of the Anatomical-Pelvic-Plane Positioner in Total Hip Arthroplasty in the Lateral Decubitus Position
    Iwakiri, Kentaro
    Kobayashi, Akio
    Ohta, Yoichi
    Takaoka, Kunio
    JOURNAL OF ARTHROPLASTY, 2017, 32 (05): : 1520 - 1524
  • [23] Three-dimensional scanner of a pipe with tilt detection
    Kawasue, Kikuhito
    Sakai, Shoji
    Wakiyama, Terufumi
    Oyama, Shigeki
    Senda, Hisashi
    ARTIFICIAL LIFE AND ROBOTICS, 2008, 13 (01) : 336 - 340
  • [24] Biomechanics of the Intra-Operative Lateral Decubitus Position for the Scoliotic Spine: Effect of the Pelvic Obliquity
    Lalonde, Nadine M.
    Aubin, Carl-Eric
    Parent, Stefan
    Pannetier, Romain
    Villemure, Isabelle
    RESEARCH INTO SPINAL DEFORMITIES 7, 2010, 158 : 95 - 100
  • [25] Three-dimensional visualization of pelvic vascularity
    Ding, Hong-Mei
    Yin, Zhi-Xun
    Zhou, Xiao-Bing
    Li, Yan-Bin
    Tang, Mao-Lin
    Chen, Sheng-Hua
    Xu, Da-Chuan
    Zhong, Shi-Zhen
    SURGICAL AND RADIOLOGIC ANATOMY, 2008, 30 (05) : 437 - 442
  • [26] Three-dimensional visualization of pelvic vascularity
    Hong-Mei Ding
    Zhi-Xun Yin
    Xiao-Bing Zhou
    Yan-Bin Li
    Mao-Lin Tang
    Sheng-Hua Chen
    Da-Chuan Xu
    Shi-Zhen Zhong
    Surgical and Radiologic Anatomy, 2008, 30
  • [27] Measuring method of three-dimensional position and orientation of a moving object for medical robots
    Uchida, T
    Koyama, H
    Komeda, T
    Miyagi, M
    Funakubo, H
    INFORMATION INTELLIGENCE AND SYSTEMS, VOLS 1-4, 1996, : 887 - 892
  • [28] Natural position of the head: review of two-dimensional and three-dimensional methods of recording
    Cassi, D.
    De Biase, C.
    Tonni, I.
    Gandolfini, M.
    Di Blasio, A.
    Piancino, M. G.
    BRITISH JOURNAL OF ORAL & MAXILLOFACIAL SURGERY, 2016, 54 (03): : 233 - 240
  • [29] The Effect of Functional Pelvic Tilt on the Three-Dimensional Acetabular Cup Orientation in Total Hip Arthroplasty Dislocations
    Snijders, Thom E.
    Schlosser, Tom P. C.
    Heckmann, Nathanael D.
    Tezuka, Taro
    Castelein, Rene M.
    Stevenson, Rob P.
    Weinans, Harry
    de Gast, Arthur
    Dorr, Lawrence D.
    JOURNAL OF ARTHROPLASTY, 2021, 36 (06): : 2184 - +
  • [30] Reliability and agreement of three-dimensional/four-dimensional transperineal ultrasound in women with chronic pelvic pain
    Mazzutti Verlangieri Carmo, Maria Aparecida
    Herren, Helmer
    Dos-Reis, Francisco J. C.
    Costa, Fabricio Da Silva
    Rosa-e-Silva, Julio C.
    Nogueira, Antonio Alberto
    Poli-Neto, Omero Benedicto
    CLINICAL AND EXPERIMENTAL OBSTETRICS & GYNECOLOGY, 2021, 48 (03): : 494 - 499