A candidate reference measurement procedure for Cyclosporine A in whole blood

被引:0
|
作者
Denis Grote-Koska
Stefan Czajkowski
Rainer Klauke
Eva Panten
Korbinian Brand
Gerhard Schumann
机构
[1] Hannover Medical School,Institute of Clinical Chemistry
来源
关键词
Cyclosporine A; Reference measurement procedure; Standardisation; Immunosuppressants; LC–MS/MS; Calibration;
D O I
暂无
中图分类号
学科分类号
摘要
Monitoring of Cyclosporine A (CsA) concentrations in whole blood is widely performed due to the narrow therapeutic index of the drug. Required standardisation for routine analysis of CsA is still missing. The candidate reference measurement procedure presented here is designated for the assignment of CsA values in hemolysed blood associated with expanded measurement uncertainty. Separate stock solutions for calibration and control materials were prepared by spiking hemolysed blood with CsA under gravimetric control. The essential sample pretreatment step was protein precipitation. Analysis was performed using isotope dilution LC-MS/MS with online solid phase extraction. Interference by matrix components was investigated. Using [2H4]-CsA as the internal standard, no interference from the investigated matrices were detected. Measurement repeatability using three pools of whole blood as samples revealed coefficients of variation (CV) ranging from 1.0 % to 1.6 %. Intermediate measurement precision was determined by repeated analysis of self-prepared control materials taken from different stock solutions of pooled whole blood. CVs were between 0.8 % and 2.4 %. Measurement accuracy was checked using three control materials prepared from three different stock solutions. The recoveries of the mean of mean values obtained on four measurement days ranged from 99.4 % to 101.3 %. The combined expanded uncertainty of measurement based on 5 days of measurement and was evaluated according to the GUM as U = 2.0 % (k = 2).
引用
收藏
页码:147 / 157
页数:10
相关论文
共 50 条
  • [31] An isotope dilution liquid chromatography-tandem mass spectrometry candidate reference measurement procedure for aldosterone measurement in human plasma
    Qiaoxuan Zhang
    Liqiao Han
    Songbai Zheng
    Fen Ouyang
    Xiaobin Wu
    Jun Yan
    Min Zhan
    Peifeng Ke
    Junhua Zhuang
    Xianzhang Huang
    Analytical and Bioanalytical Chemistry, 2021, 413 : 4471 - 4481
  • [32] MEASUREMENT OF CYCLOSPORINE A AND OF 4 METABOLITES IN WHOLE-BLOOD BY HIGH-PERFORMANCE LIQUID-CHROMATOGRAPHY
    CHRISTIANS, U
    ZIMMER, KO
    WONIGEIT, K
    SEWING, KF
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1987, 413 : 121 - 129
  • [33] CYCLOSPORINE IN WHOLE-BLOOD - COMPARISON OF 6 METHODS
    TJANDRAMAGA, TB
    VERBESSELT, R
    SCHARPE, S
    VERKERK, R
    LAMBERT, WE
    VANLIEDEKERKE, BM
    LAMEIRE, N
    DELEENHEER, AP
    PHARMACEUTISCH WEEKBLAD-SCIENTIFIC EDITION, 1988, 10 (06) : 298 - 298
  • [34] ROBOTIC AUTOMATION OF CYCLOSPORINE ANALYSIS IN WHOLE-BLOOD
    HOLMAN, JW
    FELDER, RA
    CLINICAL CHEMISTRY, 1992, 38 (08) : 1440 - 1443
  • [35] A RECEPTOR ASSAY FOR CYCLOSPORINE ACTIVITY IN WHOLE-BLOOD
    DONNELLY, JG
    SOLDIN, SJ
    CLINICAL CHEMISTRY, 1989, 35 (06) : 1167 - 1167
  • [36] CYCLOSPORINE IN WHOLE-BLOOD - COMPARISON OF 6 METHODS
    SCHARPE, S
    TJANDRAMAGA, TB
    VERBESSELT, R
    VERKERK, R
    LAMBERT, W
    VANLIEDEKERKE, B
    DELEENHEER, A
    CLINICAL CHEMISTRY, 1990, 36 (06) : 1032 - 1032
  • [37] Modification of the Abbott Cyclosporine Monoclonal Whole Blood Assay
    Guinarte, JC
    Perez, LF
    Tutor, JC
    CLINICAL CHEMISTRY, 1998, 44 (07) : 1581 - 1582
  • [38] Commutability Assessment of Processed Human Plasma Samples for Normetanephrine and Metanephrine Measurements Based on the Candidate Reference Measurement Procedure
    Deng, Yuhang
    Liu, Qingxiang
    Liu, Zhenni
    Zhao, Haijian
    Zhou, Weiyan
    Zhang, Chuanbao
    ANNALS OF LABORATORY MEDICINE, 2022, 42 (05) : 575 - +
  • [39] Development of an LC-MRM-MS-Based Candidate Reference Measurement Procedure for Standardization of Serum Apolipoprotein (a) Tests
    Ruhaak, L. Renee
    Romijn, Fred P. H. T. M.
    Brkovic, Ilijana Begcevic
    Kuklenyik, Zsusanna
    Dittrich, Julia
    Ceglarek, Uta
    Hoofnagle, Andrew N.
    Althaus, Harald
    Angles-Cano, Eduardo
    Coassin, Stefan
    Delatour, Vincent
    Deprez, Liesbet
    Dikaios, Ioannis
    Kostner, Gerhard M.
    Kronenberg, Florian
    Lyle, Alicia
    Prinzing, Urban
    Vesper, Hubert W.
    Cobbaert, Christa M.
    Int Federation Clinical Chem Lab Med Working Grp Apolipoproteins Mass Spectrometry
    CLINICAL CHEMISTRY, 2023, 69 (03) : 251 - 261
  • [40] Blood Glucose Measurement Traceability to the Primary Reference Measurement Procedure (ID-MS) for Noninvasive Glucose Monitoring
    Kuwa, Katsuhiko
    Cho, Ok Kyung
    Mitsumaki, Hiroshi
    Yasuda, Kazuo
    POINT OF CARE, 2005, 4 (01): : 41 - 44