A candidate reference measurement procedure for Cyclosporine A in whole blood

被引:0
|
作者
Denis Grote-Koska
Stefan Czajkowski
Rainer Klauke
Eva Panten
Korbinian Brand
Gerhard Schumann
机构
[1] Hannover Medical School,Institute of Clinical Chemistry
来源
关键词
Cyclosporine A; Reference measurement procedure; Standardisation; Immunosuppressants; LC–MS/MS; Calibration;
D O I
暂无
中图分类号
学科分类号
摘要
Monitoring of Cyclosporine A (CsA) concentrations in whole blood is widely performed due to the narrow therapeutic index of the drug. Required standardisation for routine analysis of CsA is still missing. The candidate reference measurement procedure presented here is designated for the assignment of CsA values in hemolysed blood associated with expanded measurement uncertainty. Separate stock solutions for calibration and control materials were prepared by spiking hemolysed blood with CsA under gravimetric control. The essential sample pretreatment step was protein precipitation. Analysis was performed using isotope dilution LC-MS/MS with online solid phase extraction. Interference by matrix components was investigated. Using [2H4]-CsA as the internal standard, no interference from the investigated matrices were detected. Measurement repeatability using three pools of whole blood as samples revealed coefficients of variation (CV) ranging from 1.0 % to 1.6 %. Intermediate measurement precision was determined by repeated analysis of self-prepared control materials taken from different stock solutions of pooled whole blood. CVs were between 0.8 % and 2.4 %. Measurement accuracy was checked using three control materials prepared from three different stock solutions. The recoveries of the mean of mean values obtained on four measurement days ranged from 99.4 % to 101.3 %. The combined expanded uncertainty of measurement based on 5 days of measurement and was evaluated according to the GUM as U = 2.0 % (k = 2).
引用
收藏
页码:147 / 157
页数:10
相关论文
共 50 条
  • [1] A candidate reference measurement procedure for Cyclosporine A in whole blood
    Grote-Koska, Denis
    Czajkowski, Stefan
    Klauke, Rainer
    Panten, Eva
    Brand, Korbinian
    Schumann, Gerhard
    ACCREDITATION AND QUALITY ASSURANCE, 2014, 19 (03) : 147 - 157
  • [2] PHENYLALANINE IN WHOLE-BLOOD AND PLASMA - A CANDIDATE REFERENCE METHOD
    LYNES, GW
    HJELM, M
    JOURNAL OF CHROMATOGRAPHY-BIOMEDICAL APPLICATIONS, 1991, 562 (1-2): : 213 - 224
  • [3] A SIMPLE PROCEDURE FOR REMOVING CYCLOSPORINE METABOLITES FROM WHOLE-BLOOD
    GIESBRECHT, E
    VERJEE, Z
    CLINICAL CHEMISTRY, 1990, 36 (06) : 1033 - 1033
  • [4] EVALUATION OF A METHOD FOR MEASUREMENT OF CYCLOSPORINE IN WHOLE-BLOOD BY HPLC
    BINDER, SR
    KEENAN, D
    REGALIA, MJ
    BIAGGI, M
    CLINICAL BIOCHEMISTRY, 1987, 20 (04) : 299 - 299
  • [5] The Alkaline Haematin Detergent (AHD575) Method for the Determination of Haemoglobin in Blood - a Candidate Reference Measurement Procedure
    Heuck, Claus Christian
    Reinauer, Hans
    Wood, William Graham
    CLINICAL LABORATORY, 2008, 54 (7-8) : 255 - 272
  • [6] Commutability Assessment of Candidate Reference Materials for Lipoprotein(a) by Comparison of a MS-based Candidate Reference Measurement Procedure with Immunoassays
    Dikaios, Ioannis
    Althaus, Harald
    Angles-Cano, Eduardo
    Ceglarek, Uta
    Coassin, Stefan
    Cobbaert, Christa M.
    Delatour, Vincent
    Dieplinger, Benjamin
    Grimmler, Matthias
    Hoofnagle, Andrew N.
    Kostner, Gerhard M.
    Kronenberg, Florian
    Kuklenyik, Zsusanna
    Lyle, Alicia N.
    Prinzing, Urban
    Ruhaak, L. Renee
    Scharnagl, Hubert
    Vesper, Hubert W.
    Deprez, Liesbet
    CLINICAL CHEMISTRY, 2023, 69 (03) : 262 - 272
  • [7] Proposal of a candidate international conventional reference measurement procedure for free thyroxine in serum
    Thienpont, Linda M.
    Beastall, Graham
    Christofides, Nicholas D.
    Faix, James D.
    Ieiri, Tamio
    Jarrige, Veronique
    Miller, W. Greg
    Miller, Richard
    Nelson, Jerald C.
    Ronin, Catherine
    Ross, H. Alec
    Rottmann, Michael
    Thijssen, Jos H.
    Toussaint, Brigitte
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2007, 45 (07) : 934 - 936
  • [8] Assessment of a reference procedure to collect and analyze glucose in capillary whole blood
    Vesper, HW
    Archibold, E
    Porter, KH
    Myers, GL
    CLINICAL CHEMISTRY, 2005, 51 (05) : 901 - 903
  • [9] An isotope dilution LC-MS/MS based candidate reference method for the quantification of cyclosporine A, tacrolimus, sirolimus and everolimus in human whole blood
    Taibon, Judith
    van Rooij, Milou
    Schmid, Rupert
    Singh, Neeraj
    Albrecht, Eva
    Wright, Jo Anne
    Geletneky, Christian
    Schuster, Carina
    Moerlein, Sophie
    Vogeser, Michael
    Seger, Christoph
    Pongratz, Stephan
    Kobold, Uwe
    CLINICAL BIOCHEMISTRY, 2020, 82 : 73 - 84
  • [10] Candidate reference method for measuring glucose in capillary whole blood and serum.
    Vesper, H
    Porter, KH
    Archibold, E
    Myers, GL
    CLINICAL CHEMISTRY, 2003, 49 (06) : A127 - A127