Carbon isotope ratio measurements of glyphosate and AMPA by liquid chromatography coupled to isotope ratio mass spectrometry

被引:0
|
作者
Dorothea M. Kujawinski
J. Benjamin Wolbert
Lijun Zhang
Maik A. Jochmann
David Widory
Nicole Baran
Torsten C. Schmidt
机构
[1] University of Duisburg-Essen,Instrumental Analytical Chemistry
[2] University of Duisburg-Essen,Centre for Water and Environmental Research (ZWU)
[3] UQAM/GEOTOP,undefined
[4] Bureau de recherches géologiques et minières (BRGM),undefined
来源
关键词
Herbicides; Carbon isotopes; Glyphosate; AMPA; CSIA; LC-IRMS;
D O I
暂无
中图分类号
学科分类号
摘要
The interest in compound-specific isotope analysis for product authenticity control and source differentiation in environmental sciences has grown rapidly during the last decade. However, the isotopic analysis of very polar analytes is a challenging task due to the lack of suitable chromatographic separation techniques which can be used coupled to isotope ratio mass spectrometry. In this work, we present the first method to measure carbon isotope compositions of the widely applied herbicide glyphosate and its metabolite aminomethylphosphonic acid (AMPA) by liquid chromatography coupled to isotope ratio mass spectrometry. We demonstrate that this analysis can be carried out either in cation exchange or in reversed-phase separation modes. The reversed-phase separation yields a better performance in terms of resolution compared with the cation exchange method. The measurement of commercial glyphosate herbicide samples show its principal applicability and reveals a wide range of δ13C values between −24 and −34 ‰ for different manufacturers. The absolute minimum amounts required to perform a precise and accurate determination of carbon isotope compositions of glyphosate and AMPA were in the sub-microgram range. The method proposed is sensitive enough to further perform the experiments that are necessary to better understand the carbon isotope fractionation associated to the natural degradation of glyphosate into AMPA. Furthermore, it can be used for contaminant source allocation and product authenticity as well.
引用
收藏
页码:2869 / 2878
页数:9
相关论文
共 50 条
  • [21] SYSTEMATIC-ERRORS IN GAS CHROMATOGRAPHY MASS SPECTROMETRY ISOTOPE RATIO MEASUREMENTS
    MATTHEWS, DE
    HAYES, JM
    ANALYTICAL CHEMISTRY, 1976, 48 (09) : 1375 - 1382
  • [22] Determination of carbon isotope ratios for honey samples by means of a liquid chromatography/isotope ratio mass spectrometry system coupled with a post-column pump
    Kawashima, Hiroto
    Suto, Momoka
    Suto, Nana
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2018, 32 (15) : 1271 - 1279
  • [23] Review: Current applications and challenges for liquid chromatography coupled to isotope ratio mass spectrometry (LC/IRMS)
    Godin, Jean-Philippe
    McCullagh, James S. O.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (20) : 3019 - 3028
  • [24] Sources of uncertainty in isotope ratio measurements by inductively coupled plasma mass spectrometry
    Appelblad, PK
    Rodushkin, I
    Baxter, DC
    ANALYTICAL CHEMISTRY, 2001, 73 (13) : 2911 - 2919
  • [25] Measurements of lead isotope ratio in cement by inductively coupled plasma mass spectrometry
    Chen, JM
    Tan, MG
    Lu, WW
    Li, YL
    Zhang, GL
    Li, Y
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2005, 33 (07) : 943 - 946
  • [26] Isotope ratio monitoring gas chromatography mass spectrometry of D H by high temperature conversion isotope ratio mass spectrometry
    Hilkert, AW
    Douthitt, CB
    Schlüter, HJ
    Brand, WA
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 1999, 13 (13) : 1226 - 1230
  • [27] High-temperature reversed-phase liquid chromatography coupled to isotope ratio mass spectrometry
    Zhang, Lijun
    Kujawinski, Dorothea M.
    Jochmann, Maik A.
    Schmidt, Torsten C.
    RAPID COMMUNICATIONS IN MASS SPECTROMETRY, 2011, 25 (20) : 2971 - 2980
  • [28] Temperature-programmed high-performance liquid chromatography coupled to isotope ratio mass spectrometry
    Godin, Jean-Philippe
    Hopfgartner, Gerard
    Fay, Laurent
    ANALYTICAL CHEMISTRY, 2008, 80 (18) : 7144 - 7152
  • [29] Identification of Natural Caffeine Source in Coffee Drinks by Liquid Chromatography Coupled with Isotope Ratio Mass Spectrometry
    Ding Bo
    Wang Zhi-Yuan
    Chen Wen-Rui
    Xie Jian-Jun
    She Zhi-Gang
    CHINESE JOURNAL OF ANALYTICAL CHEMISTRY, 2018, 46 (11) : 1802 - 1807
  • [30] Authenticity determination of tea drinks in the Chinese market by liquid chromatography coupled to isotope ratio mass spectrometry
    Ding, Bo
    Zeng, Guangfeng
    Wang, Zhiyuan
    Xie, Jianjun
    Wang, Lu
    Chen, Wenrui
    MICROCHEMICAL JOURNAL, 2019, 144 : 139 - 143