Genotyping of intron 22 inversion of factor VIII gene for diagnosis of hemophilia A by inverse-shifting polymerase chain reaction and capillary electrophoresis
被引:0
|
作者:
Tzu-Yu Pan
论文数: 0引用数: 0
h-index: 0
机构:Kaohsiung Medical University,School of Pharmacy, College of Pharmacy
Tzu-Yu Pan
Chun-Chi Wang
论文数: 0引用数: 0
h-index: 0
机构:Kaohsiung Medical University,School of Pharmacy, College of Pharmacy
Chun-Chi Wang
Chi-Jen Shih
论文数: 0引用数: 0
h-index: 0
机构:Kaohsiung Medical University,School of Pharmacy, College of Pharmacy
Chi-Jen Shih
Hui-Fen Wu
论文数: 0引用数: 0
h-index: 0
机构:Kaohsiung Medical University,School of Pharmacy, College of Pharmacy
Hui-Fen Wu
Shyh-Shin Chiou
论文数: 0引用数: 0
h-index: 0
机构:Kaohsiung Medical University,School of Pharmacy, College of Pharmacy
Shyh-Shin Chiou
Shou-Mei Wu
论文数: 0引用数: 0
h-index: 0
机构:Kaohsiung Medical University,School of Pharmacy, College of Pharmacy
Shou-Mei Wu
机构:
[1] Kaohsiung Medical University,School of Pharmacy, College of Pharmacy
[2] Kaohsiung Medical University,Department of Fragrance and Cosmetic Science, College of Pharmacy
[3] National Sun Yat-Sen University,Department of Chemistry, College of Sciences
[4] Kaohsiung Medical University Hospital,Department of Pediatrics
This is the first capillary electrophoresis (CE) analysis for diagnosis of hemophilia A (HA). The intron 22 inversion of factor VIII gene (F8) causes 40–50 % of severe bleeding disorder of HA in all human populations. Consequently, identification of the disease-causing mutations is becoming increasingly important for accurate genetic counseling and prenatal diagnosis. In this study, the key steps of inverse-shifting polymerase chain reaction (IS-PCR) and of short-end injection capillary electrophoresis were used for more specific and rapid genotyping of intron 22 inversion of F8. In IS-PCR, three specific primers were used to amplify 512-bp amplicon for wild type and 584-bp amplicon for patients with intron 22 inversion. The capillary gel electrophoresis (CGE) system was performed using 1× Tris–borate–EDTA (TBE) buffer containing 0.3 % (w/v) polyethylene oxide (PEO). The PCR amplicons were electrokinetically injected at 10 kV for 10 s at a temperature of 25 °C. The optimal short-end injection CGE was applied to detect the F8 gene of HA patients and carriers within 5 min. Intron 22 inversion was indeed found on some HA patients (13/35, 37.1 %). All genotyping results showed good agreement with DNA sequencing method and long-distance polymerase chain reaction (LD-PCR). The IS-PCR combined with short-end injection CGE method was feasible and efficient for intron 22 inversion screening of F8 in the HA populations.