Simulation of external mass transfer in hollow-fiber membrane contactors

被引:0
|
作者
V. A. Kirsch
V. I. Roldugin
S. D. Bazhenov
T. V. Plisko
机构
[1] Russian Academy of Sciences,Topchiev Institute of Petrochemical Synthesis
[2] Russian Academy of Sciences,Frumkin Institute of Physical Chemistry and Electrochemistry
[3] National Academy of Sciences of Belarus,Institute of Physical Organic Chemistry
来源
Petroleum Chemistry | 2015年 / 55卷
关键词
membrane contactor; two-dimensional flow; hollow fiber membrane; fiber row; convective diffusion; Reynolds number; Peclet number; Sherwood number;
D O I
暂无
中图分类号
学科分类号
摘要
External transverse laminar flow of a viscous incompressible fluid and convective diffusion of a solute in a model membrane contactor with a regular system of monodisperse fibers have been numerically simulated. A row of equally spaced parallel fibers was taken as the simplest model system, for which the dependences of the drag force and the efficiency of solute absorption by the fiber (Sherwood number of fiber) upon the distance between the axes of adjacent fibers, and the Reynolds and Peclet numbers have been calculated. The influence of the flow inertia has been studied, and it has been shown that the flow field and mass transport in the contactor can be described in terms of the linear Stokes approximation up to as high Reynolds numbers as dense is the fiber array.
引用
收藏
页码:776 / 782
页数:6
相关论文
共 50 条
  • [31] An Analytical Solution to Heat and Mass Transfer in Hollow Fiber Membrane Contactors for Liquid Desiccant Air Dehumidification
    Zhang, Li-Zhi
    JOURNAL OF HEAT TRANSFER-TRANSACTIONS OF THE ASME, 2011, 133 (09):
  • [32] A study on vapor transport characteristics in hollow-fiber membrane humidifier with empirical mass transfer coefficient
    Vu, Hoang Nghia
    Nguyen, Xuan Linh
    Han, Jaeyoung
    Yu, Sangseok
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2021, 177
  • [33] ENZYMATIC PEROXYCARBOXYLIC ACID FORMATION IN A HOLLOW-FIBER MEMBRANE REACTOR - KINETICS AND MASS-TRANSFER
    KRAMER, GFH
    BOUWER, ST
    VANGEMERT, RW
    DERKSEN, JTP
    CUPERUS, FP
    CATALYSIS TODAY, 1994, 22 (03) : 537 - 547
  • [34] Mass transfer in hollow-fiber modules with non-uniform hollow fibers
    Crowder, RO
    Cussler, EL
    JOURNAL OF MEMBRANE SCIENCE, 1997, 134 (02) : 235 - 244
  • [35] Mass transfer of cadmium ions in a hollow-fiber module by pertraction
    Marchese, J
    Campderrós, M
    DESALINATION, 2004, 164 (02) : 141 - 149
  • [36] Experimental and theoretical mass transfer transient analysis of copper extraction using hollow fiber membrane contactors
    Younas, Mohammad
    Druon-Bocquet, Stephanie
    Sanchez, Jose
    JOURNAL OF MEMBRANE SCIENCE, 2011, 382 (1-2) : 70 - 81
  • [37] THE USE OF EMULSIONS, MICROEMULSIONS, AND HOLLOW-FIBER CONTACTORS AS LIQUID MEMBRANES
    WIENCEK, JM
    HU, SY
    RAGHURAMAN, B
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1995, 209 : 37 - IEC
  • [38] Simulation of CO2 absorption by solution of ammonium ionic liquid in hollow-fiber contactors
    Razavi, Seyed Mohammad Reza
    Rezakazemi, Mashallah
    Albadarin, Ahmad B.
    Shirazian, Saeed
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2016, 108 : 27 - 34
  • [39] MICROPOROUS HOLLOW-FIBER MEMBRANE MODULES AS GAS-LIQUID CONTACTORS .1. PHYSICAL MASS-TRANSFER PROCESSES - A SPECIFIC APPLICATION - MASS-TRANSFER IN HIGHLY VISCOUS-LIQUIDS
    KREULEN, H
    SMOLDERS, CA
    VERSTEEG, GF
    VANSWAAIJ, WPM
    JOURNAL OF MEMBRANE SCIENCE, 1993, 78 (03) : 197 - 216
  • [40] Hollow-Fiber Coating: Application to Preparation of Composite Hollow-Fiber Membrane for Gas Separation
    Lasseuguette, Elsa
    Rouch, Jean-Christophe
    Remigy, Jean-Christophe
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2013, 52 (36) : 13146 - 13158