Methods of Increasing the Measurement Accuracy during the Experimental Determination of the Melting Point of Graphite

被引:0
|
作者
A. Yu. Basharin
M. V. Brykin
M. Yu. Marin
I. S. Pakhomov
S. F. Sitnikov
机构
[1] Institute of High Energy Density,Russian Academy of Sciences
[2] IVTAN (Institute of High Temperatures) Scientific Association,Russian Academy of Sciences
[3] Institute of High Temperatures,undefined
来源
High Temperature | 2004年 / 42卷
关键词
phase transformations in graphite; pulsed laser heating; increasing the measurement accuracy;
D O I
暂无
中图分类号
学科分类号
摘要
The experimental procedure involving pulsed laser heating is realized, which enables one to investigate phase transformations in graphite and eliminates the homogeneous condensation of carbon vapor over a sample. Data are obtained on the melting point of graphite and the temperature of crystallization of liquid carbon at a pressure of 15 MPa. The absence of a difference between the melting point of graphite at a heating rate of 100 MK/s and the temperature of crystallization of liquid carbon at the cooling rate of the melt bath of 1.6 MK/s is revealed, which is indicative of the quasi-equilibrium of the melting process. In view of this, the temperature data are averaged by a unified value of 4800±100 K. It is shown that, during the crystallization of carbon melt, highly ordered graphite with crystallites up to 250 #x00B5;m in size is formed in a liquid film 5 #x00B5;m thick on a graphite substrate.
引用
收藏
页码:60 / 67
页数:7
相关论文
共 50 条
  • [21] Experimental determination of the thermal conductivity of liquid UO2 near the melting point
    Sheindlin, M.
    Staicu, D.
    Ronchi, C.
    Game-Arnaud, L.
    Remy, B.
    Degiovanni, A.
    JOURNAL OF APPLIED PHYSICS, 2007, 101 (09)
  • [22] METHODS OF STUDYING METERING CHARACTERISTICS OF NONSTANDARD MEASUREMENT MEANS WITH AN ASSESSMENT OF THE DETERMINATION ACCURACY
    ALEKHIN, AI
    RUDYAK, IN
    REFRACTORIES, 1983, 24 (1-2): : 29 - 30
  • [23] MEASUREMENT METHODS USED FOR THE DETERMINATION OF DIMENSIONAL ACCURACY AND STABILITY OF DENTURE BASE MATERIALS
    ZISSIS, A
    HUGGETT, R
    HARRISON, A
    JOURNAL OF DENTISTRY, 1991, 19 (04) : 199 - 206
  • [24] A novel experimental method for in situ strain measurement during selective laser melting
    Wen, Yaojie
    Zhang, Baicheng
    Liu, Shuying
    Cai, Wei
    Wang, Pei
    Lee, Coryl Jing Jun
    Ma, Junda
    Qu, Xuanhui
    VIRTUAL AND PHYSICAL PROTOTYPING, 2020, 15 (S1) : 583 - 595
  • [25] EXPERIMENTAL DETERMINATION OF ACCURACY IN SENVENAN PRINCIPLE DURING COMPRESSION OF SHORT SAMPLES
    ANTIPOVA, IA
    MOROZOV, AS
    SHAIKOSHAIKOVSKII, AG
    ZAVODSKAYA LABORATORIYA, 1975, 41 (03): : 364 - 365
  • [26] Experimental determination of the effective point of measurement of a parallel-plate ionisation chamber
    Australian Radiation Lab, Yallambie
    Australas Phys Eng Sci Med, 1 ([d]1-8):
  • [28] METHODS FOR EXPERIMENTAL DETERMINATION OF BREAKING ENERGY DURING CYCLIC LOAD
    GUREVICH, SE
    GAEVOI, AP
    ZAVODSKAYA LABORATORIYA, 1973, (09): : 1110 - 1104
  • [29] Accuracy Analysis of Point Velocities Determined by Different Software Packages and GNSS Measurement Processing Methods
    Premuzic, Margareta
    Dapo, Almin
    Bacic, Zeljko
    Pribicevic, Bosko
    TEHNICKI GLASNIK-TECHNICAL JOURNAL, 2020, 14 (04): : 446 - 457
  • [30] On the accuracy of point correspondence methods in three-dimensional measurement systems using fringe projection
    Braeuer-Burchardt, Christian
    Moeller, Max
    Munkelt, Christoph
    Kuehmstedt, Peter
    Notni, Gunther
    OPTICAL ENGINEERING, 2013, 52 (06)