Shear behaviour of RC beams with corrosion damaged partial length

被引:0
|
作者
Xiao-Hui Wang
Bing Li
Xiang-Hua Gao
Xi-La Liu
机构
[1] Shanghai Jiaotong University,Department of Civil Engineering
来源
Materials and Structures | 2012年 / 45卷
关键词
Shear behaviour; Load capacity; Partial length; Corrosion of reinforced bar; Unbond;
D O I
暂无
中图分类号
学科分类号
摘要
Experimental study on shear behaviour of reinforced concrete (RC) beams with corrosion damaged partial length in one shear span is presented. In order to discover how mechanical behaviour and load capacity of the RC beam were influenced by the corrosion damaged partial length, 14 RC beams including two noncorroded RC beams, four RC beams with partially unbonded length and eight RC beams with partially corroded length were designed. The different shear span-to-effective depth ratios, the different designed partial lengths located in one shear span and the different corrosion levels within the designed partial lengths were the main considered parameters. Test results are presented in detail. Due to the different bond conditions as well as different damage status in the longitudinal bars and the contacted stirrups, the structural performance, ductility, load capacity of the test specimens with partially unbonded and corroded length are quite different. Due to the severe pitting corrosion of the longitudinal bars and rupture of the contacted stirrups within partial length of one shear span, reduced load capacity, stiffness and ductility are shown in beam with higher corrosion level within longer partial length.
引用
收藏
页码:351 / 379
页数:28
相关论文
共 50 条
  • [21] Strengthening of shear-damaged RC beams by external bonding of steel plates
    Sharif, A
    AlSulaimani, GJ
    Basunbul, IA
    Baluch, MH
    Husain, M
    MAGAZINE OF CONCRETE RESEARCH, 1995, 47 (173) : 329 - 334
  • [22] Strengthening of shear-damaged RC beams by external bonding of steel plates
    Orr, DMF
    MAGAZINE OF CONCRETE RESEARCH, 1997, 49 (181) : 369 - 370
  • [23] Effect of end anchorage in external CFRP confinement on shear damaged RC beams
    Frederick, Franklin F. R.
    Sharma, U. K.
    Gupta, V. K.
    CIVIL ENGINEERING INNOVATION FOR A SUSTAINABLE, 2015, 125 : 953 - 958
  • [24] Influence of reinforcement corrosion - in the compressive zone - on the behaviour of RC beams
    Capozucca, R
    Cerri, MN
    ENGINEERING STRUCTURES, 2003, 25 (13) : 1575 - 1583
  • [25] Analysis of reinforced concrete beams with corrosion damaged stirrups for shear capacity
    Higgins, Christopher
    Farrow, William C., III
    Turan, O. Tugrul
    STRUCTURE AND INFRASTRUCTURE ENGINEERING, 2012, 8 (11) : 1080 - 1092
  • [26] Mechanical behaviour of pitting corrosion of flexural and shear reinforcement and its effect on structural reliability of corroding RC beams
    Stewart, Mark G.
    STRUCTURAL SAFETY, 2009, 31 (01) : 19 - 30
  • [27] Shear strengthening of RC beams with corrosion-damaged stirrups using FRP grid-reinforced ECC matrix composites
    Zheng, Aohan
    Li, Shan
    Zhang, Dengfeng
    Yan, Yuhong
    COMPOSITE STRUCTURES, 2021, 272
  • [28] Flexural behaviour of damaged RC beams strengthened with ultra high performance concrete
    Prem, Prabhat R.
    Ramachandra Murthy, A.
    Ramesh, G.
    Bharatkumar, B.H.
    Iyer, Nagesh R.
    Indian Concrete Journal, 2015, 89 (01): : 60 - 68
  • [29] Shear behaviour of fire-damaged reinforced-concrete beams
    Xing, Qiong
    Liao, Jiehong
    Chen, Zhi
    Huang, Wei
    MAGAZINE OF CONCRETE RESEARCH, 2020, 72 (07) : 357 - 364
  • [30] Effects of stirrup and inclined bar corrosion on shear behavior of RC beams
    Wang, Lei
    Zhang, Xuhui
    Zhang, Jianren
    Ma, Yafei
    Liu, Yongming
    CONSTRUCTION AND BUILDING MATERIALS, 2015, 98 : 537 - 546