Improvement of internal jugular vein cannulation using an ultrasound-guided technique

被引:0
|
作者
M. Slama
A. Novara
A. Safavian
M. Ossart
M. Safar
J.-Y. Fagon
机构
[1] Service de Réanimation Polyvalente,
[2] C. H. U. Nord,undefined
[3] Place Victor Pauchet,undefined
[4] F-80054 Amiens Cedex 1,undefined
[5] France FAX: + 33 (3) 22 66 83 77,undefined
[6] Service de Réanimation Médicale,undefined
[7] Hôpital Broussais,undefined
[8] 96,undefined
[9] rue Didot,undefined
[10] F-75674 Paris Cedex 14,undefined
[11] France,undefined
来源
Intensive Care Medicine | 1997年 / 23卷
关键词
Key words Ultrasound; Venous access; Catheterization; Critical illness; Internal jugular vein;
D O I
暂无
中图分类号
学科分类号
摘要
Objective: To determine whether ultrasound guidance can help operators to improve the results of jugular vein access in the ICU. Design: Prospective, randomized study. Setting: General Intensive Care Unit of a University Hospital. Patients: Seven-nine patients were assigned to internal jugular vein cannulation using anatomical landmarks alone (control group, n = 42) or with ultrasound guidance (ultrasound group, n = 37). Intervention: All cannulations were performed by junior house staff under the direct supervision of a senior physician. In the ultrasound group, an ultrasonography (7.5 MHz) was used and the transducer was covered by a sterile sheath. The placement and direction of the cannulating needle were determined on the ultrasound image. Measurements and results: Internal jugular vein cannulation was successful in 37/37 (100 %) patients in the ultrasound group and in 32/42 patients (76 %) in the control group (p < 0.01). Average access time was longer in the control group (235 ± 408 s vs 95 ± 174 s, p = 0.06) and carotid artery puncture occurred in five patients in each group (p = 0.83). Jugular cannulation was successful at the first attempt in 26 % in the control group and 43 % in the ultrasound group (p = 0.11). Thirty-two patients (86 %) in the ultrasound group and 23 patients (55 %) in the control group (p < 0.05) were cannulated within 3 min. The cannula could therefore not be inserted within 3 min in 19 patients (45 %) in the control group. Failure was explained by thrombosis (n = 1), small caliber of the internal jugular vein (< 5 mm, n = 3), abnormal vascular relations (n = 3). Among the ten primary failures of cannulation, an internal jugular vein catheter was able to be inserted in four cases by an experienced physician on the side initially selected and with ultrasound guidance in two cases. The catheter was inserted into the contralateral internal jugular vein under ultrasound guidance in the remaining four cases. Conclusion: Ultrasound guidance improved the success rate of jugular vein cannulation in ICU patients. Our results suggest that ultrasound guidance should be used when the internal jugular vein has not been successfully cannulated within 3 min by the external landmark-guided technique.
引用
收藏
页码:916 / 919
页数:3
相关论文
共 50 条
  • [31] In reply: Ultrasound-guided internal jugular vein cannulation: techniques to confirm guidewire location
    Aoyama, Kazuyoshi
    Takenaka, Ichiro
    [J]. CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2015, 62 (12): : 1345 - 1345
  • [32] Novel maneuvers to increase the internal jugular vein diameter during ultrasound-guided cannulation
    Praveen Maheshwari
    Bradley Kelsheimer
    Parul Maheshwari
    [J]. Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2016, 63 : 898 - 900
  • [33] Ultrasound-guided cannulation of the internal jugular vein for dialysis vascular access in uremic patients
    Lin, BS
    Huang, TP
    Tang, GJ
    Tarng, DC
    Kong, CW
    [J]. NEPHRON, 1998, 78 (04): : 423 - 428
  • [34] Ultrasound-guided internal jugular vein cannulation: a novel technique for confirming that the guidewire is directed towards the right atrium
    Praveen Maheshwari
    Parul Maheshwari
    [J]. Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2016, 63 : 362 - 363
  • [35] Ultrasound-guided internal jugular vein cannulation: a novel technique for confirming that the guidewire is directed towards the right atrium
    Maheshwari, Praveen
    Maheshwari, Parul
    [J]. CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2016, 63 (03): : 362 - 363
  • [36] Cannulation of the internal jugular vein: Comparison of the classic Seldinger technique and an ultrasound guided method
    Conz, PA
    Dissegna, D
    Rodighiero, MP
    LaGreca, G
    [J]. JOURNAL OF NEPHROLOGY, 1997, 10 (06) : 311 - 313
  • [37] A Descriptive Comparison of Ultrasound-guided Central Venous Cannulation of the Internal Jugular Vein to Landmark-based Subclavian Vein Cannulation
    Theodoro, Daniel
    Bausano, Brian
    Lewis, Lawrence
    Evanoff, Bradley
    Kollef, Marin
    [J]. ACADEMIC EMERGENCY MEDICINE, 2010, 17 (04) : 416 - 422
  • [38] In reply: Ultrasound-guided internal jugular vein cannulation: a novel technique for confirming that the guidewire is directed towards the right atrium
    Kazuyoshi Aoyama
    Ichiro Takenaka
    [J]. Canadian Journal of Anesthesia/Journal canadien d'anesthésie, 2016, 63 : 364 - 364
  • [39] In reply: Ultrasound-guided internal jugular vein cannulation: a novel technique for confirming that the guidewire is directed towards the right atrium
    Aoyama, Kazuyoshi
    Takenaka, Ichiro
    [J]. CANADIAN JOURNAL OF ANESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2016, 63 (03): : 364 - 364
  • [40] A New Method for Longitudinally Increasing the Internal Jugular Vein Diameter During Ultrasound-Guided Cannulation
    Yoshida, Hitoshi
    Yaguchi, Shinya
    Kudo, Takashi
    Ono, Tomoko
    Hirota, Kazuyoshi
    [J]. ANESTHESIA AND ANALGESIA, 2012, 115 (03): : 738 - 739